Journal of the Korea Academia-Industrial cooperation Society (한국산학기술학회논문지)
- Volume 8 Issue 2
- /
- Pages.333-338
- /
- 2007
- /
- 1975-4701(pISSN)
- /
- 2288-4688(eISSN)
Behaviors of Internally Confined Hollow Reinforced Concrete Piers by Thickness of Internal Steel Tube
내부 강관 두께에 따른 내부 구속 중공 RC 교각의 거동
- Published : 2007.04.30
Abstract
An infernally confined hollow reinforced concrete pier (ICH RC pier) is hollow RC pier which has a internal steel tube to enhance its ductility and stiffness by internal confinement. In this study, the internal steel tube were changed to investigate the behavior of ICH RC pier. The behavior of internally confined hollow reinforced concrete piers were evaluated with safety ratio, ductility, total material cost, the total weight of the pier, etc. As a result of analytical study, the usage of a minimum necessary thickness of the internal steel tube the most effective. The ICH RC pier has decrease of weight compare to Solid RC pier.
내부 구속 중공 RC 교각은 교각의 강성 및 연성의 증가를 목적으로, 중공 RC 교각의 중공 면에 내부 구속력을 제공하는 강관을 삽입한 교각이다. 본 연구에서는 내부 강관의 두께를 변화시켜 내부 구속 중공 RC 교각의 거동 특성을 파악하였으며, 거동 특성을 파악하기 위한 평가 방법으로는 안전율, 연성능력, 재료비, 교각의 총중량 등으로 평가하였다. 해석적 연구 결과, 내부 구속 중공 RC 교각의 내부 강관 두께는 최소 필요 두에를 적용하는 것이 가장 효과적인 것으로 나타났다. 또한, 중공 단면에 대한 교각의 자중감소 효과를 확인할 수 있었다.