참고문헌
-
Ammann, D., P. Anker, E. Metzger, U. Oesch, W. Simon, M. Kessler, D.K. Harrison and J. Hoper. 1985. Neutral carrier based silicone rubber membranes for
$H_3O^+,\;K^+$ ,$NH_4^+$ and$Ca^{2+}$ selective electrodes. Springer-Verlag, Berlin, Heidelberg, pp.102 - Bae, Y. M. and S. I. Cho. 2002. Response of polymer membranes as sensing elements for an electronic tongue. Trans. ASAE 45(5):1511-1518
- Campanello, L., C. Colapicchioni, R. Crescenti M.P. Sarnmartino, Y. Su and M. Tomassetti. 1995. Sensitive membrane ISFETs for nitrate analysis in waters. Sens. Actu. B27(1-3):329-335
- Craggs, A., G. J. Moody and J. D. R. Thomas. 1974. PVC matrix membrane ion-selective electrodes. J. of Chem. Educ. 51(8):541-544 https://doi.org/10.1021/ed051p541
- Deyhimi, F. 1999. A method for the determination of potentiometric selectivity coefficients of ion selective electrodes in the presence of several interfering ions. Talanta 50:1129-1134 https://doi.org/10.1016/S0039-9140(99)00194-0
- Didina, S., L. Mitnik, N. Koshmina, A. Grekovich and K. Mikhelson. 1994. Lead-selective electrodes based on liquid ion-exchangers. Sens. Actu. B19(1-3):396-399
- Hong, U. S., H. K Kwon, G. S. Cha, H. H. Nam, S. H. Chang and K. B. Chung. 1995. Benzothiazole substituted benzocrown ether-based potassium ion-selective membrane electrodes. J. of the Korean Chem. Soc. 39(9):698-704. (In Korean)
-
Kim, G. Y. 2003. Application of a strip ion-selective electrode sensor for hydroponic nutrient solution analysis -
$NO_3^-$ analysis. J. of the Korean Soc. for Agricultural Machinery 28(4):335-342. (In Korean) https://doi.org/10.5307/JBE.2003.28.4.335 - Kim, H. J., J. W. Humrnel, and S. J. Birrell. 2006. Evaluation of nitrate and potassium ion-selective membranes for soil macronutrient sensing. Trans. ASABE 49(3):597-606 https://doi.org/10.13031/2013.20476
- Kim, M. K., K. H. Ryu, Y. S. Jang, and G. Y. Kim. 2002. Study on automatic mixing of nutrient solution using ion electrodes for closed-loop hydroponics. J. of the Korean Soc. for Agri. Machinery 27(5):425-432. (In Korean) https://doi.org/10.5307/JBE.2002.27.5.425
- Knoll, M., K. Cammann, C. Dumschat, M. Borchardt and G. Hogg. 1994. Microfibre matrix-supported ion-selective PVC membranes. Sens. Actu. B20(1):1-5
- Lee, H. L. 1986. Ion-selective electrodes. The magazine of the IEEK 13(1):36-43. (In Korean)
- Moody, G. J. 1985. Mechanistic studies of ion-selective electrodes. J. of Biom. Engi. 7(3):183-195 https://doi.org/10.1016/0141-5425(85)90019-6
- Ruzicka, J., E. Hansen and J. Tjell. 1973. The calcium selectrode employing a new ion exchanger in a nonporous membrane and a solid-state reference system. Anal. Chim. Acta 67:155- 178 https://doi.org/10.1016/S0003-2670(01)80243-9
- Wegmann, D., H. Weiss, D. Ammann, W.E. Morf, E. Pretsch, K. Sugahara and W. Simon. 1984. Anion-selective liquid membrane electrodes based on lipophilic quaternary ammonium compounds. Microchim. Acta 84(1-2):1-16 https://doi.org/10.1007/BF01204153