발전용 밸브누설 평가를 위한 다중계측 연구

Study on the Multi-measuring Method for Evaluation of Internal Leak of Power Plant Valve

  • 이상국 (한전 전력연구원 원자력발전연구소) ;
  • 박성근 (한전 전력연구원) ;
  • 박종혁 (한전 전력연구원) ;
  • 김광홍 (한전 전력연구원) ;
  • 김영범 (시스템 디엔디(주) 부설연구소)
  • 발행 : 2007.08.31

초록

Leak would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leak at present are analysis of ${\Delta}T$, AE(Acoustic Emission) analysis, and thermal image. The result for test of secondary system in nuclear power plant Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leak is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So we think that using the Multi-Measuring method is more sound judgment than single-measuring method.

키워드