DOI QR코드

DOI QR Code

신축 공동주택에서 실내공기오염물질(휘발성유기화합물 및 카보닐화합물) 농도분포 특성

Characteristics of concentration distribution for indoor air pollutants (VOCs and Carbonyl compounds) in new apartments

  • 장성기 (국립환경과학원 실내환경과) ;
  • 천재영 (국립환경과학원 실내환경과) ;
  • 이태형 (국립환경과학원 실내환경과) ;
  • 임수길 (국립환경과학원 실내환경과) ;
  • 류정민 (국립환경과학원 실내환경과) ;
  • 서수연 (국립환경과학원 실내환경과) ;
  • 임정연 (국립환경과학원 실내환경과)
  • Jang, Seong-Ki (Indoor Air Quality Division, National Institute of Environmental Research) ;
  • Chun, Jae-Young (Indoor Air Quality Division, National Institute of Environmental Research) ;
  • Lee, Tae-Young (Indoor Air Quality Division, National Institute of Environmental Research) ;
  • Lim, Soo-Gil (Indoor Air Quality Division, National Institute of Environmental Research) ;
  • Lu, Jung-Min (Indoor Air Quality Division, National Institute of Environmental Research) ;
  • Seo, Soo-Yun (Indoor Air Quality Division, National Institute of Environmental Research) ;
  • Lim, Jeong-Yun (Indoor Air Quality Division, National Institute of Environmental Research)
  • 투고 : 2006.11.16
  • 심사 : 2006.12.02
  • 발행 : 2007.02.28

초록

신축공동주택에서 발생되는 실내공기 오염물질 중 휘발성유기화합물 및 카보닐화합물의 농도분포특성을 파악하고자 신축공동주택 120세대를 대상으로 실내공기 오염도 실태조사를 실시한 결과, 입주 전 신축공동주택의 실내공기 오염물질 농도는 톨루엔이 $272.81{\mu}g/m^3$, m, p-자일렌 $98.90{\mu}g/m^3$, 포름알데히드 $71.68{\mu}g/m^3$, 아세톤 $70.58{\mu}g/m^3$, 에틸벤젠 $49.76{\mu}g/m^3$로 조사되었다. TVOCs 물 구성비의 경우, 표준물질로 확인된 물질이 42.5%를 차지하였으며, 이 중 톨루엔이 18.5%로 가장 많은 비중을 차지하였다. 카보닐화합물의 경우, 포름알데히드와 아세톤이 각각 43.1%, 42.4%를 차지하였다. 또한, 주요 실내공기 오염물질의 실내/실외 농도비를 조사한 결과 벤젠은 1.29로 낮은 농도비로 조사되었으며, 톨루엔은 3.59, 포름알데히드는 10.76, o-자일렌은 28.74의 실내/실외 농도비를 나타내었다.

This study was performed to investigate the distributions of volatile organic compounds and carbonyl compounds at the 120 households in new apartments before occupation. The concentration of toluene, m, p-xylene, formaldehyde, acetone and ethylbenzene dominated as $272.81{\mu}g/m^3$, $98.90{\mu}g/m^3$, $71.68{\mu}g/m^3$, $70.58{\mu}g/m^3$ and $49.76{\mu}g/m^3$, respectively. The identified compounds by standards occupied 42.5% of the TVOCs, also the concentration of toluene occupied the largest part of the identified compounds as 18.5%. The concentration of formaldehyde and acetone were 43.1% and 42.4% among carbonyl compounds. The indoor/outdoor ratio of the concentration of benzene, toluene, formaldehyde and o-xylene were investigated 1.29, 3.59, 10.76 and 28.74, respectively.

키워드

참고문헌

  1. 장성기, 이석조, 유승화, 정경미, 류정민, 한국실내환경학회지 1(1), 12-24 (2004)
  2. Jones A.P, Atmospheric Environment, 33, 4535-4564 (1999) https://doi.org/10.1016/S1352-2310(99)00272-1
  3. 조장제, 구민호, 장정욱, 손승연, 김태오, 한국대기환 경학회 2004 춘계학술대회 논문집 (2004)
  4. Lee, S. C. and M. Chang, Chemosphere, 41, 109-113 (2000) https://doi.org/10.1016/S0045-6535(99)00396-3
  5. 전형진 등, 한국실내환경학회 2005 연차학술대회 논 문집, 138-142(2005)
  6. WHO's Regional Office for Europe Reprots, Working Group on Indoor Air Reseach, 264-268(1984)
  7. 환경부, 다중이용시설 등의 실내공기질관리법 (2005)
  8. 환경부, 실내공기질 공정시험방법 (2004)
  9. 신동천, 이효민, 김종만, 정용, 한국대기보전학회지, 6(1), 33-43(1990)
  10. 김윤신, 조별아, 한국대기보전학회 1996 춘계학술대 회요지집, 189-190(1996)
  11. 송희봉, 민경섭, 한개희 김종우, 백성옥, 대한환경공학회 1995 추계학술연구발표회, 340-343(1995)
  12. 신혜수, 김윤신, 허귀석, 한국대기보전학회지, 9(4), 310-319(1993)
  13. S.O. Back, Y.S. Kim, and R. Perry, Atmos. Environ, 31, 529-544(1997) https://doi.org/10.1016/S1352-2310(96)00215-4
  14. 송희봉, 다수인 이용시설에서의 실내공기질 특성 평가, 영남대학교 박사학위 논문(1999)
  15. S.O Baek, and R.A. Jenkins, Indoor Built Environ, 10, 200-208(2001) https://doi.org/10.1177/1420326X0101000313
  16. 국립환경과학원, 신축공동주택 실내공기질 권고기준 설정 연구(II) (2005)
  17. 임미정, 한국대기환경학회 2005 추계학술대회 논문집, 545-547(2005)