Selection of Concrete Surface Impregnant through Durability Tests

내구성 실험을 통한 최적 표면침투제의 선정

  • 권성준 (비앤티 엔지니어링) ;
  • 박상순 (한국건자재시험연구원) ;
  • 이상민 (비앤티 엔지니어링) ;
  • 김종우 ((주)유디코, 상지대학교 건설시스템 공학과)
  • Received : 2006.06.19
  • Published : 2007.11.30

Abstract

The repair technique utilizing surface impregnant is widely used due to its simple construction procedures and economical benefit. Surface protection through this reparing technique cannot increase the bearing capacity of concrete members much but increase the durability performance and service life efficiently. In this study, fundamental tests such as water suction and permeation are performed for concrete specimens with several organic/inorgarnic impregnant and suitable impregnant is selected on the basis of the results. Finally, durability tests such as carbonation, freezing and thawing, and chloride attack are carried out for the concrete specimens with selected impregnant and it is experimentally verified that they have good resistance to deteriorations.

표면침투제를 사용하여 콘크리트 표면을 경화시키는 보수공법은 간단한 시공방법 뿐 아니라 경제적인 방법으로 최근들어 많이 사용되고 있다. 이러한 표면보호공 또는 보수방법은 강도에 대해서는 크게 개선효과를확보하기는 어렵지만, 공극을 치밀하게 형성함으로서 내구적인 저항을 개선하고 내수구명을 연장할 수 있다. 본 연구에서는 다양한 유/무기계 표면침투제를 사용한 콘크리트 시편에 대하여 흡수성, 투수성과 같은 기초적인 실내실험을 수행하였으며, 이에따라 최적의 표면침투제를 선정하였다. 이후 선정된 표면침투제에 대하여 다양한 내구성 실험(탄산화, 동결융해, 염해저항성, 내화학성)이 수행되었으며, 선정된 2가지 표면침투제를 사용한 콘크리트 시편은 우수한 내구적 저항성을 가지고 있음을 실험적으로 규명하였다.

Keywords

References

  1. 권성준, 송하원, 박찬규, 변근주, "공극구조를 고려한 탄산화된 콘크리트의 투수 특성에 대한 연구", 대한토목학회 논문집, Vol. 25 No. 3A, 2005, pp. 577-583.
  2. 박상순, 송하원, 변근주, "균열을 갖는 콘크리트의 염화물 확산 및 투수모델". 대한토목학회 논문집 Vol. 21, No. 6-A, 2001, pp. 915-924.
  3. 양은익, 김명유, 노병철, 김정훈, "표면침투제에 따른 콘크리트의 염화물 침투와 동결융해 저항성에 대한 평가", 콘크리트 학회 논문집, 제18권, 1호, 2006, pp. 65-72. https://doi.org/10.4334/JKCI.2006.18.1.065
  4. 유성원, 서정인, 하헌재, 이상민, 이상근, "고성능 표면침투제가 도포된 콘크리트의 물리 특성, 한국콘크리트 학회 가을학술논문집", 16권, 2호, 2004, pp. 233-236.
  5. 이용준. "표면침투제를 적용한 기존 콘크리트의 내구성 향상", 상지대학교 석사학위논문, 2003, 12.
  6. 和泉意登志, 喜多達夫, 前田熙信, 中性化, 技報堂出版, 1986.
  7. Bungey, J.H. and Millard, S.G., Testing of Concrete in Structure, Blackie Academic & Professional, 1996.
  8. CEB, General Task Group 20, Durable concrete structure-Design Code, CEB, Thomas Telford, 1989.
  9. Emmons, P.H., Concrete Repair and Maintenance Illustrated, R.S. Means Company, 1994.
  10. Ishida, T. and Maekawa, K., "Modeling of PH Profile in Pore Water Based on Mass Transport and Chemical Equilibrium Theory", Concrete Library of JSCE, No. 37, June, 2001, pp. 151-166.
  11. Papadakis, V,G., Vayenas, C.G., and Fardis, M.N., "Fundamental Modeling and Experimental Investigation of Concrete Carbonation," ACI Materials Journal, V. 88, No 4, 1991, pp. 363-373.
  12. Ishida, T., Soltani, M., and Maekawa, K., "Influential Parameters on the Theoritical Prediction of Concrete Carbonation Process", Proceedings 4th International Conference on Concrete Under Severe Conditions, Seoul, Korea 2004, pp. 205-212.
  13. Tang, L. and Nilsson, L.O.,"Rapid Estimation of Chloride Diffusivity in Concrete by Applying an Electrical Field", ACI Material Journal, Jan-Feb., 1992, pp. 49-53.