A Study on the Required Supply Water Temperature Calculating Method for the Control of Multizone Radiant Floor Heating System

멀티존 온돌난방제어를 위한 필요공급온수온도 산출법에 관한 연구

  • Choi, Jeong-Min (Department of Architecture, Graduate School, Seoul National University) ;
  • Lee, Kyu-Nam (Department of Architecture, Graduate School, Seoul National University) ;
  • Ryu, Seong-Ryong (Department of Architecture, Graduate School, Seoul National University) ;
  • Kim, Yong-Yee (Department of Architecture, College of Engineering, Kunsan National University) ;
  • Yeo, Myoung-Souk (Department of Architecture, College of Engineering, Seoul National University) ;
  • Kim, Kwang-Woo (Department of Architecture, College of Engineering, Seoul National University)
  • 최정민 (서울대학교 대학원 건축학과) ;
  • 이규남 (서울대학교 대학원 건축학과) ;
  • 류성룡 (서울대학교 대학원 건축학과) ;
  • 김용이 (군산대학교 건축공학과) ;
  • 여명석 (서울대학교 건축학과) ;
  • 김광우 (서울대학교 건축학과)
  • Published : 2007.01.10

Abstract

One of the most common approaches to achieve better thermal comfort with the radiant floor heating system is supply water temperature control, which is that supply water temperature is varied with outdoor air temperature. But the application of this control method was not easy, because there has been no way to determine the supply water temperature. So in this study, a comprehensive, yet simple calculation method to find out the required supply water temperature is suggested by combining the building heat loss equation and the heat emission model of hydronic radiant floor heating system for single zone. And then using this calculation method, the multizone control method is suggested and confirmed through the thermal simulation. It is shown that indoor air temperature is stably maintained around the set point.

Keywords

References

  1. Twintran, 1989, Twintran Application Mannual, Heatway System, p. 40
  2. EN1264-2, 1999, Floor heating: System and components, Parts 2: Determination of thermal output
  3. Yeo, M. S., Seok, H. T. and Kim, K. W., 1998, A study on the water temperature control method of radiant floor heating system in apartment buildings, Proceedings of AIK, Vol. 14, pp.203-210
  4. Adelman, T. N., 1949, Radiant Heating, The Industrial Press, pp, 163-171
  5. Liao, Z. and Dexter, A. L., 2005, An experimental study on an inferential control scheme for optimizing the control of boilers in multizone heating system, Energy and Buildings, 37, pp.55-63 https://doi.org/10.1016/j.enbuild.2004.05.009
  6. Jin, W. F., Rhie, M. K., Yeo, M. S. and Kim, K. W., 2004, A study on the individual room control of radiant floor heating system in apartment building, Proceedings of SAREK, Vol. 16, pp. 421-429