Abstract
The PCS system, which consists of precast concrete column and steel beam, is a kind of composite structural systems. In this paper, experimental study has been conducted to analyze seismic performance of bolted beam-to-column connections for the PCS system. Based on experimental results from the seismic testing of eight interior PCS specimens, it shows that behavior of PCS system is satisfactory to seismic performance criteria of ACI such as strength deterioration, stiffness degradation and energy dissipation capacity except initial stiffness. All of the specimens maintain their strength at large levels of story drift without significant loss of stiffness and show high ductility level for inelastic behavior. The energy dissipation capacity is two times greater than requirement of ACI criterion. But the initial stiffness of all specimens does not satisfy ACI criterion, and this phenomenon is similar to the other composite structural systems such as RCS, CFT system.
PCS 구조 시스템은 프리캐스트 콘크리트 기둥과 철골보로 이루어진 합성 구조 시스템의 일종이다. 이 시스템은 접합부를 볼트로 연결함으로써 완전건식공법이며 조립식이어서 시공성 및 경제성 면에서 많은 장점을 가지고 있다. 본 연구에서는 실험체를 구성하는 PC 기둥 및 접합부를 개발하였으며, PCS 구조 시스템의 구조적 특성과 내진 성능을 파악하기 위하여 다양한 실험을 수행하였다. 실험 결과 개발된 PC 기둥은 손상 이후에도 강도 성능을 유지하는 우수함을 보였다. 철골보의 스캘럽은 파괴 모드 조절 및 에너지소산 능력에 효율적인 것으로 나타났으며, 단부 평판으로 구속된 접합부는 그 강도 성능이 매우 우수하였다 타설된 슬래브는 파괴 모드 조절 및 에너지소산 능력에 바람직하지 못한 효과를 보였다. 내진 성능 분석 결과 PCS 구조 시스템은 초기 강성을 제외한 강도 및 강성 저하, 에너지소산 성능의 ACI 기준을 모두 만족하는 것으로 나타났으며 매우 우수한 것으로 분석되었다. 초기 강성의 경우 PCS 구조 시스템은 다른 합성 구조와 비슷한 수준이었으며, 일반콘크리트 및 철골조도 ACI의 기준을 만족하지 못하는 것으로 조사되었다. 이러한 이유는 ACI의 초기 강성 평가 기준이 부분 구조 실험체만으로는 만족하는데 한계가 있기 때문이다. 그러므로 본 연구에서 수행된 PCS 구조 시스템은 내진 성능 및 역학적 성능이 매우 우수한 것으로 판단된다.