EFFECTS OF DIFFERENT OXIDIZED SURFACES OF IMPLANT ON OSSEOINTEGRATION; RESONANCE FREQUENCY AND HISTOMORPHOMETRIC ANALYSIS STUDY IN MINI-PIGS

다양한 양극산화막 처리방법이 임플란트 골유착에 미치는 영향

  • Kwon, Kyung-Hwan (Department of Oral & Maxillofacial Surgery, School of Dentistry, Wonkwang University) ;
  • Min, Seung-Ki (Department of Oral & Maxillofacial Surgery, School of Dentistry, Wonkwang University) ;
  • Sung, Dae-Hyuk (Department of Oral & Maxillofacial Surgery, School of Dentistry, Wonkwang University) ;
  • Choi, Jae-Young (Department of Oral & Maxillofacial Surgery, School of Dentistry, Wonkwang University) ;
  • Choi, Seung-Lim (Department of Oral & Maxillofacial Surgery, School of Dentistry, Wonkwang University) ;
  • Cha, Su-Ryeon (Department of Oral & Maxillofacial Surgery, School of Dentistry, Wonkwang University) ;
  • Oh, Hee-Kyun (Department of Maxillofacial Surgery, School of Dentistry, Chonnam National University)
  • 권경환 (원광대학교 치과대학 구강악안면외과학교실) ;
  • 민승기 (원광대학교 치과대학 구강악안면외과학교실) ;
  • 성대혁 (원광대학교 치과대학 구강악안면외과학교실) ;
  • 최재영 (원광대학교 치과대학 구강악안면외과학교실) ;
  • 최성림 (원광대학교 치과대학 구강악안면외과학교실) ;
  • 차수련 (원광대학교 치과대학 구강악안면외과학교실) ;
  • 오희균 (전남대학교 치과대학 구강악안면외과학교실)
  • Published : 2007.09.30

Abstract

The aim of the present study is to investigate the effect of anodized surface of osseointegration implants by using of resonance frequency analysis (RFA) and histomorphometric analysis. A total of 96 screw-shaped implants were devided into 4 groups. Seventy-two implants were prepared by electrochemical oxidation with 3 different ways; Group 1 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid, Group 2 (n=24) were prepared at galvanostatic mode in calcium glycerophosphate and calcium acetate, and Group 3 (n=24) were prepared at galvanostatic mode in 0.25M sulfuric acid and phosphoric acid followed by Calcium metaphosphate(CMP) coating. Control group (n=24) were the RBM surfaced implants. The implants were placed in the mandibles of 12 mini pigs. Bone tissue responses were evaluated by resonance frequency analysis(RFA) and histomorphometric analysis that were undertaken at 2, 4 and 6weeks after implant placement. The following result were obtained. 1. Twenty-two of 96 implants (4 in control group, 5 in group 1, 7 in group 2, and 6 in group 3) were failed due to faliure of osseoitegration. The failure rate of osseointegration was 22.9%. 2. The mean values of RFA in control, group 2 and groups 3 showed the similar values, but there was no significant difference among groups. 3. Histomorphometric evaluation demonstrated significantly higher bone-to-implant contact ratio in group 2 at 3 and 4 weeks after implant placement than other groups (p<0.05), but there was no significant difference among groups at 6weeks after implant placement.

Keywords

References

  1. Branemark PI : Osseointegration and its experimental background. J Prosth Dentistry 50 : 399, 1983 https://doi.org/10.1016/S0022-3913(83)80101-2
  2. Branemark PI, Hansson BO, Adell R et al : Osseointergated implants in the treatment of the edenfulous jaw.Experience from a 10 year period.Scand J Plast Reconstr Surg 16 : 7, 1977
  3. Albrektsson T, Zarb G, Worthington P : The long-term efficacy of currently used dental implants. A review and proposed criteria of success. Int J Oral Maxillofac Implant 1(1) : 11, 1986
  4. Buser D, Schenk RK, Steinemann S et al : Influence of surface characteristics on bone integration of titanium implant. A histomorphometric study in miniature pigs. J Biomed Mater Res 25 : 889, 1991 https://doi.org/10.1002/jbm.820250708
  5. Albreksson T, Branemar PI, Hansson HA et al : Osseointergated titanium implants. Acta Orthp Scand 52 : 155, 1981 https://doi.org/10.3109/17453678108991776
  6. Deporter DA, Watson PA, Pilliar RM et al : A histological comparison in the dog of porous-coated vs threaded dental implants. J Dental Res 69 : 1138, 1990 https://doi.org/10.1177/00220345900690050401
  7. Haas R, Mensdorff-Pouilly N, Mailath G et al : Survial of 1,920 IMZ implants followed for up to 100 months. Int J Oral Maxillofac Implants 11 : 581, 1996
  8. Buser D, Nydegger T, Hirt HP et al : Removal torque values of titanium implants in the maxilla of miniature pigs. Int J Oral Maxillofac Implants 13 : 611, 1998
  9. Lazzara RJ, Testori T, Trisi P et al : A human histologic analysis of Osseotite and machined surfaces using implants with 2 opposing surface. Int J Periodontic Restorative Dent 19 :117, 1999
  10. Sul YT, CB, Petronis S et al : Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition. Biomaterials 23 : 491, 2002 https://doi.org/10.1016/S0142-9612(01)00131-4
  11. Sul YT, CB, Petronis S, Roser K et al : Qualitative and quantitative observations of bone tissue reactions to anodised implants. Ahistologic, enzyme histochemical and histomorphometric analysis. Biomaterials 23 : 1809, 2002 https://doi.org/10.1016/S0142-9612(01)00307-6
  12. Sul YT, Johansson, CB, Jeong Y et al : Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides. Clin Oral Impl Res 13 : 252, 2002 https://doi.org/10.1034/j.1600-0501.2002.130304.x
  13. Piattelli M, Scarano A, Paolantonio M et al : Bone response to machined and resorbable blast material titanium implants : an experimental study in rabbits. J Oral Implantol 28 : 2, 2002 https://doi.org/10.1563/1548-1336(2002)028<0002:BRTMAR>2.3.CO;2
  14. Cooper LF : A role of surface topography in creating and maintaining bone at titanium endosseous implants J Prosth Dent. 84 : 522, 2000 https://doi.org/10.1067/mpr.2000.111966
  15. Mefferd RM, Langer B, Fritz ME : Dental implants : A review. J Periodontol 63 : 859, 1992 https://doi.org/10.1902/jop.1992.63.11.859
  16. Joos U, Wiesmann HP, Szuwart T et al : Mineralization at the interface of implants. Int J Oral Maxillofac Surg 35 : 783, 2006 https://doi.org/10.1016/j.ijom.2006.03.013
  17. Zechner W, Tangl S, Furst G et al : Osseous healing characteristics of three different implant types : A histologic and histomorphometric study in mini-pigs. Clin Oral Imp Res 14 : 150, 2003 https://doi.org/10.1034/j.1600-0501.2003.140203.x
  18. Marinho VC, Celleti R, Brachetti G : Sandblasted and Acid-etched Dental Implants : A Histologic study in Rats. Int J Oral Maxillofac Implants. 18 : 75, 2003
  19. Brunette DM, Ratkay J, Chehroudi B : Behavior of Osteoblasts on micromachined surfaces. In : Davies JE(ed) The bone-Biomaterial interface. Toronto : University of Toronto Press 170 : 1991, p.18
  20. Lausmaa J, Kasemo B : Surface spectroscopic characterization of titanium implant materials. Appl Surf Sci 44 : 133, 1990 https://doi.org/10.1016/0169-4332(90)90100-E
  21. Lausmaa J, Kasemo B : Surface spectroscopic characterization of titanium implant materials. Appl Surf Sci 44 : 133, 1990 https://doi.org/10.1016/0169-4332(90)90100-E
  22. Zitter H, Plenk HJ : The electrochemical behaviour of metallic implant materials as indicator of their biocompatibility. J Biomed mater Res 21 : 881, 1987 https://doi.org/10.1002/jbm.820210705
  23. Olefjord I, Hansson S : Surface analysis of four dental implant system. Int J Oral Maxillofac Implants 8 : 32, 1993
  24. Meredith N : Assessment of implant stability as a prognostic determinant. Int J Prothodont 11(5) : 491, 1998
  25. Barewal RM, Oates TW, Meredith N et al : Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Maxillofac implant 18 : 641, 2003
  26. Werner Zechner, Stefan Tangl, Gabor Furst et al : Osseous healing characteristics of three different implant types. Clin Oral Impl Res 14 : 150, 2003 https://doi.org/10.1034/j.1600-0501.2003.140203.x
  27. Sul YT, Johansson CB : The electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes. medical engineering & Physics 23 : 329, 2001 https://doi.org/10.1016/S1350-4533(01)00050-9
  28. Grook K, Geesink R, Klein C et al : Plsama sprayed coatings of hyroxyapatite. J Biomedical Materials Reseach 21 : 1375, 1987
  29. Wennerberg A, Albreksson T, Andersson B : An animal study of c. p. Titanium screws with different surface topographies. J Materials Science : materias in Medicine 6 : 302, 1995 https://doi.org/10.1007/BF00120275
  30. Wennerberg A, Albrektsson T, Andersson B et al : A histomerphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Impl Res 5 : 24, 1995