Abstract
Some network equipments made in Korea were exposed to severe earthquake in Japan several years ago. More than a hundred slim base transfer network stations had been seized with the severe earthquake at Nigata and it was reported that less than fifteen sets showed blackout by interruption of electricity, not by the structural failure. The purpose of this paper is to check the structural safety of the network equipments by performing table test, and the static and dynamic finite element analysis. For the dynamic test, the station weighing 200 kg was subjected to the Zone 3 earthquake loading of GR-63-CORE on the shaking table to obtain the dynamic responses to compare with the analysis results. It is shown that the FE analysis results are a little bit larger than that of the experimental values. And the sensitivity analysis and optimization for the natural frequency is performed and it is found that the first natural frequency is sensitive to small design change as shown in the results. And the dynamic response of optimized design is less than the original design.
최근 일본에서 발생한 지진으로 이동통신용 전자장비들이 많이 파손되었으나. 국내에서 제작되어 일본에 설치된 모제품은 강진에서도 대부분 구조적 손상이 없었다. 본 논문에서는 이동통신 네트워크 장비의 정/동적 특성을 평가하기 위하여 제품의 유한요소 모델을 생성하여 정적 및 동적 구조해석을 수행하였다. 또한 Zone 3 GR-63-CORE 동적 실험을 수행하여 제품의 안정성을 검증하였고, 유한요소 구조해석 결과와 비교하여 실험과 해석 결과가 유사함이 입증되었다. 구조해석 결과인 동적 응답특성은 실험보다 다소 크게 나왔으며, 부재의 특성파악을 위해 구조물의 치수를 설계변수로 하여 진동특성에 대한 민감도 해석으로 고유진동수에 민감한 부재를 판별하였고, 치수변경으로 경량화 설계치를 산출하였다. 경량화된 디자인의 동적 응답변위가 원래 디자인보다 작게 나와 최적화 결과가 유용할 것으로 보인다.