혼합 효율 향상을 위한 마이크로 동적 믹서의 형상최적화

Shape Optimization of an Active Micro-Mixer for Improving Mixing Efficiency

  • 박재용 (한양대학교 대학원 기계공학과) ;
  • 김상락 (한양대학교 대학원 기계공학과) ;
  • 이원구 (한양대학교 대학원 기계공학과) ;
  • 유진식 (한양대학교 대학원 기계공학과) ;
  • 김용대 (한양대학교 대학원 기계공학과) ;
  • 맹주성 (한양대학교 기계공학부) ;
  • 한석영 (한양대학교 기계공학부)
  • 발행 : 2007.12.15

초록

An active micro-mixer, which was composed of an oscillating micro-stirrer in the microchannel to provide rapid, effective mixing at high flow, rates was analyzed. The effects of molecular diffusion and disturbance by the stirrer were considered with regard to two types of mixer models: the simple straight microchannel and microchannel with an oscillating stirrer. Two types of mixer models were studied by analyzing mixing behaviors such as their interaction after the stirrer. The mixing was calculated by Lattice Boltzmann methods using the D2Q9 model. In this study, the time-averaged mixing index formula was used to estimate the mixing performance of time-dependent flow. The mixing indices of the two models compared. From the results, it was found that the mixer with an oscillating stirrer was much more enhanced and stabilized. Therefore, an optimum design for a dynamic micro-mixer with an oscillating stirrer was performed using Taguchi method in order to obtain a robust solution. The design parameters were established as the frequency, the length and the angle of the stirrer and the optimal values were determined to be 2, 0.8D and ${\pm}75^{\circ}$, respectively. It was found that the mixing index of the optimal design increased 80.72% compared with that of the original design.

키워드

참고문헌

  1. Bertsch, A., Heimgartner, S., Cousseau, P. and Renaud, P., 2001, Static Micromixers Based on Large- scale Industrial Mixer Geometry, Lab on a Chip, vol. 1, pp. 56-60 https://doi.org/10.1039/b103848f
  2. Liu, R. H., Mark, A. S., Kendra, V. S., Michael, G. O., Juan, G. S. and Ronald, J. A., 200, 'Passive Mixing in a Three-dimensional Serpentine Microchannel,' J. Microelectromech. Syst., vol. 9, pp. 190-197 https://doi.org/10.1109/84.846699
  3. Anderson, R. C., Bogdan, G. J., Puski, A. and Su, X., 1998, 'Genetic analysis Systems: Improvenemts and Methods,' Proc. Solid-State Sens. Actuator Workshop, Hiltion Head, SC, pp. 7-10
  4. Bisson, C., Campbell, J., Cheadle, R., Chomiak, M., Lee, J., Miller, C., Milley, C., Pialis, P., Shaw, S., Weiss, W. and Widrig, C., 1998, 'Microanalytical Device for the Assessment of coagulation Parameters in Whole Blood,' Proc. solid-State Sens. Actuator Workshop, Hilton Head, SC, pp. 1-6
  5. Chiem, N., Colyer, C. and Harrison, J. D., 1997, 'Microfluidic Systems for clinical Diagnostics,' Proc. Int. Solid-State Sens. Actuatiors Conf., Chicago, IL, pp. 183-186
  6. Chiem, N., colyer, C. and Harrison, J. D., 1997, 'Microfluidic Systems for clinical Diagnostics,' Proc. Int. Solid-State Sens. Actuatiors Conf., Chicago, IL, pp. 183-186
  7. Girault, H. H., Josserand, J. and Mengeaud, V., 2002, 'Mixing Processes in a Zigzag Microchannel: Finite Element Simulations and Optical Study,' Analytical chemistry, Vol. 74, No. 16, pp. 4279-4289 https://doi.org/10.1021/ac025642e
  8. Kim, Y. D., An, S. J. and Maeng, J. S., 2006, 'The Effect of Karman Vortex for Mixing in a Microchannel with an Oscillation Micro-Stirrer,' J. of KSME Series B, Vol. 30, No. 2, pp. 144-152 https://doi.org/10.3795/KSME-B.2006.30.2.144
  9. An, S. J., Kim, Y. D. and Maeng, J. S., 2006, 'A Study on Mixing Enhancement by Rotating and Oscillating Stirrers in the Micro Channel,' J. of KSME Series B, Vol. 30, No. 5, pp. 430-437 https://doi.org/10.3795/KSME-B.2006.30.5.430
  10. Williamson, C. H. K., 1996, 'Vortex Dynamics in the Cylinder Wave,' Annu. Rew. Fluid. Mech., Vol. 28, pp. 477-539 https://doi.org/10.1146/annurev.fl.28.010196.002401
  11. Kim, Y. D., 2007, A study for mixing Characteristics and Performance of an Active Micro-Mixer by the Lattice Boltzmann Method. Doctorial Thesis, Hanyang Univ., Seoul, Korea
  12. Park, S. H., 2003, Design of Experiments, Minyoung Press