Abstract
Lightning warning system plays an important role in protecting human life and other facilities from lightning return strokes. This paper dealt with lightning positioning algorithms and circuits as a main function of lightning warning system, which monitor movements and activities of thunderclouds. Electric field component produced by lightning discharge is detected by the configuration of a whip antenna and a narrow-band resonance amplifier with center frequency of 300[kHz]. Measurement circuit of magnetic field waveform consists of a crossed-loop coil and an integral amplifier, and its frequency bandwidth is ranges from 5[kHz] to 1.2[MHz]. The polarity of lightning discharge is discriminated by electric field component. After-fixing the polarity, we can calculate the direction and distance of lightning discharge by the peak and the zero-cross time of magnetic field waveform.
뇌경보시스템은 낙뢰에 의한 인적 물적 피해를 예방하는 중요한 장치이다. 본 논문에서는 뇌경보시스템의 주요기능으로 뇌운의 이동과 활동을 감시할 수 있는 뇌방전 위치표정 알고리즘 및 회로에 대해 연구하였다. 뇌방전시 발생하는 전계성분은 whip 안테나와 공진주파수 300[kHz]의 협대역 공진증폭기로 검출한다. 자계파형 측정회로는 직교루프코일과 적분증폭기로 구성되며 주파수 대역은 5[kHz]$\sim$1.2[MHz]이다. 전계파형으로 뇌방전의 극성을 판별하고, 자계파형의 크기와 영점교차점에 의해 방향과 거리를 산출하여 뇌방전의 위치를 표정한다.