Journal of the korean academy of Pediatric Dentistry (대한소아치과학회지)
- Volume 34 Issue 2
- /
- Pages.222-233
- /
- 2007
- /
- 1226-8496(pISSN)
- /
- 2288-3819(eISSN)
Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations
Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석
- Lee, Sang-Ik (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
- Hyun, Hong-Keun (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
- Kim, Young-Jae (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
- Kim, Jung-Wook (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
- Lee, Sang-Hoon (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
- Kim, Chong-Chul (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
- Hahn, Se-Hyun (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University) ;
- Jang, Ki-Taeg (Department of Pediatric Dentistry, College of Dentistry and Dental Research Institute, Seoul National University)
- 이상익 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
- 현홍근 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
- 김영재 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
- 김정욱 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
- 이상훈 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
- 김종철 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
- 한세현 (서울대학교 치과대학 소아치과학교실 및 치학연구소) ;
- 장기택 (서울대학교 치과대학 소아치과학교실 및 치학연구소)
- Published : 2007.05.31
Abstract
One of the most important and basic test of dental restorative materials is the evaluation of microleakage into the tooth-restorative interface. There are many techniques to test microleakage, but most of them have several disadvantages. Recently developed microtomography(micro-CT) can provide the three dimensional image and information about the internal component in non-destructive way, therefore using micro-CT, it is possible to evaluate microleakage exactly in quantitative manner. The purpose of this study is to find a new method for quantitative and non-destructive evaluation of microleakage in composite resin restorations using micro-CT and to compare the new method with conventional dye penetration method. Thus, microleakages of two kinds of dentin bonding systems were evaluated with above two methods. 40 extracted sound human premolars were randomly divided into two groups consisting of 20 samples and restored accordingly. Group 1 : Class V resin restorations with
치과 수복 재료 검사 시 가장 중요하고 기본적인 것은 치아와 수복물 사이의 미세누출에 대한 평가이다. 미세 누출을 평가하는 방법은 여러 가지가 있지만 이들 대부분은 많은 단점들을 가지고 있다. 최근에 개발된 미세 단층촬영법(micro-CT)을 이용하면 시편을 비파괴적으로 처리하여 특정 밀도에 해당하는 부분의 3차원적 영상을 얻을 수 있으므로, 이를 이용하면 정확하고 정량적인 미세누출 평가도 가능할 것이다. 이 연구의 목적은 micro-CT를 사용하여, 레진 수복물의 미세 누출도를 정량적이고 비파괴적으로 측정할 수 있는 새로운 방법을 찾아내고, 이 새로운 방법을 기존의 색소 침투법과 비교해보는 것이다. 이를 위해, 위의 두 가지 방법을 사용하여 두 종류의 상아질 접착 시스템의 미세누출도가 평가되었다. 사람의 건전 소구치 40개를 임의로 20개씩 두 군으로 나누고 다음과 같이 처리하였다. Group 1 :
Keywords