참고문헌
- K. S. Ha, S. J. Park, S. J. Seo, J. H. Park, D. H. Chung, 'Incidence and polymerase chAlN reaction assay of listeria monocytogenes from raw milk in Gyeongnam Province of Korea', J. Food Protection, vol, 65, pp. 111-115. 2001
- F. P. Anderson, W. G. Miller, 'Fiber optic immunochaemical sensor for continuous, reversible measurement of phenytion', Chin. Chem, vol. 34, pp. 1417-1421, 1988
- B. I. Blusetein, I. M. Walczak and S. Y. Chen, 'Fibe optic evanescent wave immunosensors for medical diagnostics', TIBTECH, vol. 8, pp. 161-168, 1999
- L. A. Tempelman, K. D. Anderson, F. S. Ligler, 'Quantitation Staphylococcal enterotoxin B in diverse media using a portable fiber-optic biosensor', Anal. Biochem, vol. 34, pp. 50-57, 1996
- S. H. Lee, D. D. Stubbs, J. Cariney, W. D. Hunt, 'Real-time detection of bacteria spores using a QCM based immunosensor', Sensors. Proc. IEEE, vol. 2, pp. 1194-1198, 2003
-
A. Loni, G. Hay, R. M. De La Rue, J. M. Winfield, 'Proton-exchanged
$LiNbO_3$ waveguides; the effects of post-exchange annealing and buffered melts as determined by infrared spectroscopy, optical waveguide measurements, and hydrogen isotopic exchange reactions', J. Lightwave Technology, vol. 7, pp. 911-919, 1989 https://doi.org/10.1109/50.32358 - G. Sakai, I. Ogata, T. Uda, N. Miura, N. Yamazoe, 'Highly sensitive detection of morphine by using immunosensor based on surface plasmon resonance', Solid State Sensors and Actuators, vol. 1, pp. 179-182, 1997 https://doi.org/10.1109/SENSOR.1997.613612
- A. Johnston, 'Trends in biosensor research and development', Electron Devices Meeting; Technical Digest., pp. 654-657, 1998
- L. Lading, L. B. Nielsen, T. Seve1, 'Comparing biosensors', Sensors; Proc. IEEE, vol. 1, pp. 229-232, 2002
- M. McShane, S. Rastegar, G. Cote, 'Fluorescencebased implantable biosensors: Monte Carlo modeling for optical probe design', Engineering in Medicine and Biology Society, vol. 4, pp. 1799-1802, 1998
- D. Lipson, N. G. Loebel, K. D. McLeaster, B. Liu, 'Multifiber, multiwavelength, fiber optic fluorescence spectrophotometer', Biomedical Engineering, vol. 39, pp. 886-892, 1992 https://doi.org/10.1109/10.256421
- S. McCulloch, D. Uttamchandani, 'Development of a fibre optic micro-optrode for intracellular pH measurements', Optoelectronics; Proc. IEEE, vol. 144, pp. 162-167, 1997
- S. McCulloch, D. Uttamchandani, 'Fibre optic microoptrode for dissolved oxygen measurements', Science; Measurement and Technology, vol. 146, Issue: 3, pp. 123-127, 1999 https://doi.org/10.1049/ip-smt:19990077
- U. J. Krull. R. S. Brown, E. T. Vandenberg, B. D. Hougham, 'Optical biosensors from chemical transduction by lectrins and neural recptors', Engineering in Medicine and Biology Society; Proc. the Annual International Conference of the IEEE, vol. 2, pp. 793-794, 1998
- D. Lipson, N. G. Loebel, K. D. McLeaster, B. Liu, 'Multifiber, multiwavelength, fiber optic fluorescence spectrophotometer', Biomedical Engineering; IEEE Transactions on, vol. 39, Issue: 9, pp. 886-892, 1992
- 이수미, 고광락 강신원, '소산장 흡수를 이용한 박막광도파로형 칼륨이온센서', 센서학회지, 제6권, 제3호, pp. 214-220, 1997
- H. J. Kwon, J. O. Spiker, H. Balcer, K. A. Kang, 'A kinetic study on fiber optic immunosensor for the detection of protein C', Engineering in Medicine and Biology; Biomedical Engineering Soc; BMES/EMBS Conference, vol. 2, pp. 807, 1999
- El-Hang Lee, R. E. Benner, J. B. Fenn, and R. K. Chang, 'Angular distribution of fluorescence from liquids and monodispersed spheres by evanescent wave excitation', Applied Optics, vol. 18, Issue 6, pp. 862-868, 1979 https://doi.org/10.1364/AO.18.000862
- Toyoda Gosei-LED, Retrieved October 10,2007, from http://www.toyoda-gosei.com/led/products/products2.html
- Advantest products directory 2001, Retrieved October 10, 2007, from http://gtcsales.co.kr/mAlN/advantest/pdf/044.pdf
- H. J. Jung, 'Fiber-optic fluoroimmunosensor for detection of salmonella', Master thesis, Kyungpook National University, 2004
- G. P. Anderson, J. P. Golden, F. S. Ligler, 'An evanescent wave biosensor. I. Fluorescent signal acquisition from step-etched fiber optic probes', Biomedical Engineering; IEEE Transactions on, vol. 41, Issue: 6, pp. 578-584, 1994
- R. Dahint, F. Bender, 'A concentration dependent study of acoustic plate mode immunosensor response using antigen/antibody systems with different binding ability', Ultrasonics, Ferroelectric and Frequency Control, vol. 45, Issue: 5, pp. 1216-1220, 1998 https://doi.org/10.1109/58.726446
피인용 문헌
- Volatile organic compounds gas sensor using side polished optical fiber vol.19, pp.6, 2010, https://doi.org/10.5369/JSST.2010.19.6.428