Abstract
Purpose: The purpose of this study was to compare the method of using coraco-clavicular (C-C) sling with modified Phemister operation by postoperative clinical results, radiologic analysis and complications. Materials and Methods: 33 patients of acromioclavicular joint dislocation were included in this study. Thirteen patients were treated with simple C-C sling method and twenty patients were treated with modified Phemister operation. The assesment of clinical and radiological evaluation were performed and the final results were examined by using the Weitzman's classification. Results: In the final result of C-C sling method group, forward elevation $161^{\circ}$, external rotation $70^{\circ}$, internal rotation T8 level, Visual Analogue Scale (VAS) 83.3 points were checked. In modified Phemister operation group, forward elevation $155^{\circ}$, external rotation $67^{\circ}$, internal rotation T6 level, VAS 83.8 points were checked. In coracoclavicular distance of C-C sling method group, pre-operation 12.82 mm and last follow up 8.37 mm were checked. In modified Phemister operation group, pre-operation 12.8 mm and last follow up 7.7 mm were checked. In functional evaluation by the Weitzman criteria, C-C sling group had excellent 8, good 1, fair 1 and modified Phemister group had excellent 13, good 4, fair 3. Conclusion: C-C sling method would be the better than the Modified Phemister operation because of short operation time and smaller skin incision.