Absorptive Separation of Sulfur Dioxide using Flat Membrane Contactor

평판형 분리막 접촉기를 이용한 이산화황 흡수 분리

  • Lee Yong-Taek (Department of Chemical Eng., Chungnam National University) ;
  • Lee Young-Jin (Department of Chemical Eng., Chungnam National University) ;
  • Song In-Ho (Department of Chemical Eng., Chungnam National University) ;
  • Jeon Hyun-Soo (Department of Chemical Eng., Chungnam National University) ;
  • Ahn Hyo-Seong (Department of Chemical Eng., Chungnam National University) ;
  • Lee Hyung-Keun (Korea Institute of Energy Research)
  • Published : 2006.09.01

Abstract

A flue gas emission known to cause an acid rain, containing sulfur dioxide, is tightly controlled by a regulation. The membrane contactor could be one of the alternatives which might be useful technologies for better performance of desulfurization. The fundamental sulfur dioxide separation data were obtained by a flat membrane contactor so that they could be utilized for the full scale membrane contactor. The separation of sulfur dioxide was measured in terms of the concentration of NaOH absorbent, the concentration of sulfur dioxide, the feed flow rate and different membrane materials. As the concentration of absorbent increased, the removal efficiency increased. By increasing the concentration of sulfur dioxide, the removal efficiency decreased. As the feed flow rate increased, it was observed that the removal efficiency decreased. Finally, the effect of the membrane material on separation was found to be negligible.

산성비의 한 가지 원인으로 알려진 이산화황($SO_2$)을 포함한 대기 오염물질인 연도 기체의 배출 허용 기준이 엄격해지고 있다. 배연 탈황 기술의 효율을 획기적으로 높일 수 있는 분리막 접촉기의 개발에 필요한 기초 설계 자료를 제공하고자 평판형 분리막 접촉기 실험 장치를 설계 및 설치하여 이산화황 투과 특성 평가를 수행하였다. 평판형 분리막 접촉기를 이용한 이산화황의 제거에 미치는 흡수제 농도와 공급 기체 내의 이산화황 농도의 영향, 공급 기체 유량 및 분리막 재질에 따른 영향을 확인하고자 하였다. 흡수제 농도가 증가할수록 이산화황 제거 효율이 증가하였으며, 이산화황 농도가 증가할수록 제거 효율이 감소하였다. 또한 공급 기체 유량이 증가할수록 제거 효율이 감소하였으며 분리막 재질은 제거 효율에 큰 영향을 끼치지 않음을 확인할 수 있었다.

Keywords

References

  1. 조영환, 김희택, 류경옥, 이영수, 'Water-hydrated Ca-based sorbent의 이산화황 제거에 관한 연구', 화학공학의 이론과 응용, 3(2), 2597 (1997)
  2. 이철수 외 20명, '접촉막 소재제조 및 응용공정 기술확보를 위한 중장기 전략수립', 산업자원부, 고려대학교 (2002)
  3. R. D. Noble and S. A. Stern, 'Membrane Separations Technology: Principles and Applications', Elsevier Science B. V., Amsterdam, The Netherlands, 467 (1995)
  4. P. H. M. Feron and A. E. Jansen, '$CO_2$ separation with polyolefin membrane contactors and dedicated absorptions liquids: performances and prospects', Separation and Purification Tech., 27, 231 (2002) https://doi.org/10.1016/S1383-5866(01)00207-6
  5. H. Kreulen, C. A. Smolders, G. F. Versteeg, and W. P. M. van Swaaij, 'Determination of mass transfer rates in wetted and non-wetted microporous membranes', Chem. Eng. Sci., 48, 2093 (1993) https://doi.org/10.1016/0009-2509(93)80084-4
  6. Z. Qi and E. L. Cussler, 'Microporous hollow fibers for gas absorption: Mass transfer in the liquid', J. Membr. Sci., 23, 321 (1985) https://doi.org/10.1016/S0376-7388(00)83149-X
  7. 최승학, 김정훈, 김범식, 이수복, '폴리이서설폰 중공사모듈을 이용한 연소배가스로부터 이산화탄소 분리회수를 위한 다단계 막분리공정 연구', 멤브레인, 15(4), 310 (2005)
  8. M. S. Chun and K.-H. Lee, 'Separation Science and Technology', 32(15), 2445 (1997) https://doi.org/10.1080/01496399708000779
  9. V. Y Dindore, D. W. F. Brilman, F. H. Geuzebroek, and G. F. Versteeg, 'Membrane-solvent selection for $CO_2$ removal using membrane gas-liquid contactors', Separation and Purification Tech., 40, 133 (2004) https://doi.org/10.1016/j.seppur.2004.01.014
  10. M. Mulder, 'Basic principles of membrane echnology', Kluwer Academic Publishers, Dordrecht, The Netherlands (1996)
  11. Y. Lee, J. Jeong, I. J. Youn, and W. H. Lee, 'Modified liquid displacement method for determination of pore size distribution in porous membrane', J. Membr. Sci., 130, 149 (1997) https://doi.org/10.1016/S0376-7388(97)00017-3