This paper reports the apparatus and method for the safe treatment of pentachlorophenol(PCP)-treated ammunition box by solvent extraction. Experimental variables were chosen as the composition of solvents, types of substance(chips and sawdust), temperatures and sonication to obtain maximum PCP removal from wood samples of the dismantled ammunition box. Up to 99% of PCP in the wood chip was extracted within 2 hours at room temperature when using methanol as the solvent. The extraction volume ratio of methanol per dried sample was about 10. Type of samples, extraction temperature and sonification showed little effects on PCP extraction. Based on this study, a resource recycling system for the treatment of ammunition boxes was recommended.

Keywords

References

  1. Environmental Health Criteria 71, "Pentachlorophenol", International Programme on Chemical Safety, WHO, Geneva, 1987. http://inchem.org/documents/ehc/ehc/ehc71.htm
  2. Lorber, M. N., Barton, R. G., Winters, D. L., Bauer, K.M., Davis, M., and Palausky, J. "Investigation of the potential release of polychlorinated dioxins and furans from PCP-treated utility poles", The Science of the Total Environment, Vol. 29, pp.15-39, 2002
  3. Pal, N., Korfiatis, G. P., and Patel, V., "Sono-chemical extraction and biological treatment of pentachlorophenol contaminated wood", J. of Hazardous Materials, Vol. 53, pp.165-182, 1997 https://doi.org/10.1016/S0304-3894(96)01839-0
  4. Lamar, R. T., and Scholze, R. T., "White-rot fungi biodegradation of pcp-treated ammunition box" in Proceedings of R&D 92 National research development conference on the control of hazardous materials, U.S.A., 1992
  5. 최인기 "phanerochaete chrysosporium"에 의한 PCP 폐기물의 미생물 분해, 대한민국 특허 10-0282256, 2000
  6. 류원률, 심성훈, 조무환 등, "백색 부후균에 의한 Pentachlorophenol의 생분해", Vol. 5, No. 1, 춘계 화학공학회 학술발표논문집, pp.1949-1952, 1999
  7. U.S. Federal Specification, "Wood Preservative : Water Repellent", TT-W-572B, 1969
  8. 국방규격, 국방-8140-0006-1(연), 1988.6.30 수정
  9. 공업진흥청 고시 제92-10호, "오염화석탄산 및 포르말린 함유 품질검사 기준", 1992
  10. 이종철, 최수, "오염화석탄산(PCP)으로 방부처리된 목재로부터 PCP의 용매추출", Korean Chem. Eng. Res., Vol. 44, No. 2, pp.227-233, 2006
  11. Tennessee Valley Authority, "Summary of PCP-treated Wood Waste Management at Army Installations", Prepared for U.S. Army Environment Center(USAEC) APG, MD, USA, 1999