Evaluation of Wear Efficiency and Subjective Wear Sensation According to the Structures of Smart Clothing for the Measurement of Vital Sign

생체신호측정용 스마트 의복의 구조에 따른 착용효율성 및 주관적 착용감 평가

  • Lee, Hyun-Young (Department of Clothing and Textiles, Kunsan National University)
  • Published : 2006.12.31

Abstract

In this paper, various structures of the healthcare smart clothing for real-time measurement of vital sign were suggested. The wearing efficiency was evaluated to find out the best ergonomic clothing in the suggested design. The supplementary effects of the clothing components (princess line, double fabric, cushion) on the stable and tight positioning of sensors to the body were evaluated with wear test. Five experimental clothing for male subject were made with closely-fitted shape and they included two representative structure: one was the integrated type of inner and outer garments and the other was the separated type with two garments. Eight subjects in their twenties were participated in the wear test to evaluate the wearing efficiency of experimental clothing. As results, the clothing structure of the separated garments with the inner and the outer shells were evaluated as more efficient and comfortable. However, the effects of clothing components on the light positioning of the sensors to the body surface were not differentiated each other in the subjective evaluation.

Keywords