Development of Small Size Coriolis Mass Flowmeter

소형 코리올리 질량 유량계의 개발

  • 임기원 (한국표준과학연구원 유체유동그룹) ;
  • 지정근 ((주)하이트롤 기술연구소)
  • Published : 2006.06.01

Abstract

A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

Keywords

References

  1. Li, Y. T. and Lee, S. Y., 1953, 'A Fast Response True Mass Rate Flowmeter,' Trans. Am. Soc. Mech. Engrs, Vol. 75, pp. 835-841
  2. Medlock, R. S., 1989, 'A Review of the Techniques of Mass Flow Measurement,' International conference on mass flow measurement, London, England
  3. 日本 計量機器工業連合會,1995,'流量計測 A to Z,' 第10章, pp. 161-183
  4. Tse, F. S., Morse, I. E. and Hinkle, R T., 1978, 'Mechanical Vibrations( second edition),' Allyn and Bacon, Inc
  5. Ki Won Lim, 2001, 'A Study on the Measurement Uncertainty of Flowmeter Calibrator,' Trans. of the KSME (B), Vol. 25, No.4, pp. 561-571
  6. ISO 4185, 1983, Measurement of Liquid Flow in closed conduits - Weighing Method