Abstract
The precast concrete beam-column connectors for the high-rise office buildings were investigated experimentally in this study. The specimens of general precast beam-column connector which is used in a domestic site, specimen of DDC(dywidag ductile connectors) of Germany, and specimen of DDC with post-tensioning and modified DDC with post-tensioning were constructed and tested to verify the safety. The DDC with and without post-tensioning showed reliable joint strength and ductility but failed in critical inclined shear crackings at the column. The modified one showed better behaviors in tests because they did not show critical column crackings at failure. The use of prestressing did not helpful significantly to increase the strength and ductility of connectors but helpful only to develop self-centering behavior for stability.
본 연구에서는 주상복합건물에 적용가능한 건식공법에 의한 프리캐스트 콘크리트 보-기둥 연결부에 대하여 실험을 통하여 분석하였다. 현재 국내에 활용하고 있는 프리캐스트 콘크리트 보-기둥 연결부와 현재 미국에서 사용되고 있는 DDC 연결부, 그리고 DDC 연결부와 개선된 연결부에 포스트텐션을 도입한 시험체를 제작하였고, 실험을 통하여 그 거동을 평가하였다. 실험 결과 보-기둥 연결부에 DDC 시스템을 적용하게 되면 연결부의 강도와 연성능력의 향상을 기대할 수 있었으나 파괴 메커니즘이 보에 에너지를 분산시키지 않고, 연결부에서 사인장 균열에 의하여 에너지를 소산시키게 되어 연결부가 파괴되는 단점이 나타났다. 개량 DDC 연결부는 기둥에 사인장균열이 발생하지 않고 보다 연성적인 파괴거동을 보여주었다. 또한 보-기둥 연결부에 포스트텐션의 도입은 연결부 강도의 증가는 크게 기대할 수 없었으나 자가조정(self-centering) 등을 통하여 연결부의 안정성 및 연성능력에 기여하는 것으로 나타났다.