A Laboratory Test and Numerical Analysis to Determine the Number of Additional Installation of Face Bolts due to the Deviated Bolts from the Horizontal Direction

막장볼트가 수평으로부터 벗어나는 경우 추가해 주어야 하는 본수에 대한 실내실험 및 수치해석

  • Published : 2006.12.29

Abstract

During installation of face bolts, they are often deviated from the designed horizontal direction. In this study, a laboratory test and numerical analysis were conducted to examine the change of support effect by them. Also, the number of bolts to be added for achieving the designed support effect was considered. It was verified in this study that the horizontal installation is more effective. Under the test condition of this study, 1.5 bolts/section should be added in the face of which the installation density was 3 bolts/section when the bolts were installed with $R15^{\circ}$ angle from the horizontal position.

막장볼트는 시공중 지반조건 및 천공기계의 기계적 원인에 의해 수평으로부터 벗어나게 타설되는 경우가 많다. 본 연구는 실내실험과 수치해석을 통하여 막장볼트가 수평으로부터 벗어나는 경우에 대한 보강효과의 변화를 검증하였다. 또한 이 결과를 바탕으로 추가해 주어야 하는 볼트의 개수에 대하여 고찰하였다. 본 연구로부터 막장 중앙부부터 타설하는 막장볼트는 가능한 한 수평으로 타설하는 것이 효과적이며 벗어나는 경우에는 볼트를 추가해 주어야 하는 것이 명확해 졌다. 본 연구의 조건하에서는3본/단면을 타설 할 경우 모든 볼트가 $R15^{\circ}$로 수평으로부터 벗어나면 1.5본/단면을 추가해 주어야 하는 것으로 나타났다.

Keywords