Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode

전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구

  • Published : 2006.07.01

Abstract

We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.

Keywords

References

  1. M. Ishijima, 'Monitoring of Electrocardiograms in Bed Without Utilizing Surface Electrodes', IEEE Trans. Biome. Eng., Vol 40, pp 593-594, 1993 https://doi.org/10.1109/10.237680
  2. M. Ishijima, 'Long-term Cardiopulmonary Monitoring in Bed Without Subject Awareness', IEEE EMB. 18th Annual Int. Conf., pp 65-66, 1996
  3. M. Ishijima, 'Cardiopulmonary Monitoring by textile electrodes without subject-awareness of being monitored', Med. BioI. Eng. Comput., Vol 35, pp 685-690, Nov 1997 https://doi.org/10.1007/BF02510978
  4. M. Ogawa, T. Togawa, 'Attempts at Monitoring Health Status in Home', IEEE EMBS. 1st Annual Int. Conf, pp 552-556, 2000
  5. W.J. Yi, K.S. Park, 'Derivation of Respiration from ECG Measured Without Subject's Awareness Using Wavelet Transform', IEEE EMBS/BMES. Conf, pp 130-131, 2002
  6. D. Dobrev, ' Two-electrode low supply voltage electrocardiogram signal amplifier', Med. BioI. Eng. Comput., Vol 42, pp 272-276, 2004 https://doi.org/10.1007/BF02344642
  7. G.B. Moody, R.G. Mark, A. Zoccola, S. Mantero, 'Derivation of respiration signals from multi-lead ECGs', Computers in Cardiology, Vol 12, pp 113-116, 1985
  8. G.B. Moody, R.G. Mark, M.A. Bump, J.S. Weinstein, 'Clinical validation of ECG-derived respiration technique', Computers in Cardiology, Vol 13, pp 507-510, 1986
  9. 박성빈, 이계형, 김경환, 윤형로, '힐버트 변환에 기반한 순간주파수 추정을 이용한 개선된 심전도 유도 호흡신호 추출 알고리즘', 대한전기학회, Vol 53D, No 10, pp 733-740, 2004
  10. D. Dobrev, I. Daskalov, 'Two-electrode telemetric instrument for infant heart rate and apnea monitoring', Medical. Eng. Physi., Vol 20, pp 729-734, 1998 https://doi.org/10.1016/S1350-4533(98)00091-5
  11. DL. Eckberg, 'Human sinus arrhythmia as an index of vagal cardiac outflow', J Appl Physiol, Vol 54(4), pp 961-966, 1983 https://doi.org/10.1152/jappl.1983.54.4.961
  12. J. Hayano, F. Yasuma, A. Okada, et al, 'Respiratory sinus arrhythmia : a phenomenon improving pulmonary gas exchange and circulatory efficiency', Circulation, Vol 94, pp 842-847, 1996 https://doi.org/10.1161/01.CIR.94.4.842
  13. L. Zhao, S. Reisman, T. Findley, 'Respiration from the electrocardiogram during heart rate variability studies', IEEE Comp. in Cardiol., Vol 21, pp 53-56, 1994
  14. A. Travaglini, C. Lamberti, J. De Bie, 'Respiratory of signal derived from eight-lead ecg', IEEE Comp. in Cardiol., Vol 25-2, pp 65-68, 1998
  15. D. Caggiano, S. Reisman, ' Respiration derived from electrocardiogram: a quantitative comparison of three different methods', Proceeding of the IEEE twenty-second annual, pp 103-104, 1996
  16. D. Laude, M. Goldman, P. Escourrou, et al, 'Effect of breathing pattern on blood pressure and heart rate oscillations in humans', Clin Exp Pharmacol Physiol, Vol 20, pp 619-626, 1993 https://doi.org/10.1111/j.1440-1681.1993.tb01643.x
  17. P. Sleight, B. Casadei, 'Heart Rate Variability, Ch.24 Relationships Between Heart Rate, Respitarion and Blood Pressure Variabilities, Futura Publishing, pp 311-327, 1995
  18. B.H. Taha, P.M. Simson, J.A. Dempsey, J.B. Skatrud, C. Iber, 'Respiratory sinus arrhythmia in human : an obligatory role for vagal feedback from the lung', J Appl Physiol, Vol 78(2), pp 638-645
  19. D.L. Eckberg, C. Nerhed, B.G. Wallin, 'Respiratory modulation of muscle sympathetic and vagal cardiac outflow in man', J Physiol, Vol 365, pp 961-966, 1985
  20. J.P. Saul, R.D. Berger, P. Albercht, S.P. Stein, M.H. Chen, and R.J. Cohen, 'Transfer function analysis of the circulation: unique insights into cardiovascular regulation', Am. J. Physiol, 261(30), pp H1231-H1245, 1991 https://doi.org/10.1152/ajpheart.1991.261.4.H1231
  21. T.C. Chou, 'Electrocardiography in clinical practice-adult and pediatric', Saunders, pp 3-22, 1996
  22. A.V. Oppenheim, R.W. Schafer, 'Discrete Time Signal Processing', Prentice Hall, p.207 - 220, 1989
  23. W.J.M. Hrushesky, D. Fader, O. Schmitt, V. Gilbertsen, 'The respiratory sinus arrhythmia : a measure of cardiac age', Science, Vol 224, pp 1001-1004, 1984 https://doi.org/10.1126/science.6372092
  24. J. Hayano, F. Yasuma, 'Respiratory sinus arrhythmia : Why dose the Heartbear Syncronize withe Reipratory Rhythm?', Chest, Vol 125, pp 683-690, 2004 https://doi.org/10.1378/chest.125.2.683
  25. B.E. Shykoff, S.S.J. Naqvi, A.S. Menon, et al. 'Respiratory sinus arrhythmia in dogs: effects of phasic afferents and chemostimulation.', J Clin Invest, Vol 87, pp 1621-1627, 1991 https://doi.org/10.1172/JCI115176
  26. 박성빈, '선형 모텔링에 의한 수면 무호홉 환자의 자율신경 제어 평가에 관한 연구', 연세대학교 대학원 학위논문, 2004
  27. T.J. Mullen, M.L. Appel, R. Mukkamala, J.M. Mathias, R.J. Cohen, 'System identification of closed-loop cardiovascular control: effects of posture and autonomic blockade', Am. J. Physiol. 272 : H448-H461, 1997