Effects of Accumulator Heat Exchanger on the Performance of a Refrigeration System

열교환기 내장형 어큐뮬레이터가 냉동시스템의 성능에 미치는 영향에 관한 연구

  • Kang Hoon (Graduate School of Mechanical Engineering, Korea University) ;
  • Choi Kwang-Min (Graduate of School of Mechanical Engineering, Korea University) ;
  • Park Cha-Sik (Graduate of School of Mechanical Engineering, Korea University) ;
  • Kim Yong-Chan (Dept. of Mechanical Engineering, Korea University)
  • 강훈 (고려대학교 기계공학과 대학원) ;
  • 최광민 (고려대학교 기계공학과 대학원) ;
  • 박차식 (고려대학교 기계공학과 대학원) ;
  • 김용찬 (고려대학교 기계공학과)
  • Published : 2006.05.01

Abstract

An AHX (Accumulator Heat exchanger) consists of a commercial accumulator and an inner heat exchanger located inside of the accumulator. The AHX is used in multi air-conditioners to assure that liquid-phase refrigerant enters into the expansion device. This purpose is achieved by heat transfer between the refrigerant leaving the evaporator and the refrigerant leaving the condenser. In this study, the effects of AHX on the performance of a refrigeration system using R-22 were measured and the test results were analyzed. The operating characteristics of the refrigeration system with the AHX are considerably different from those without the AHX. Therefore, it is required to determine optimum refrigerant charge and optimum operating conditions when the AHX is used in the refrigeration system having a constant flow-area expansion device such as capillary tube.

Keywords

References

  1. Wood, C. W. and Meyer, J. P., 1999, Experimental verification of a universal accumulator heat exchanger design procedure used to achieve liquid overfeeding effects in small air conditioning systems, Proceedings of ASME, Vol. 39, pp. 99-103
  2. Meyer, J. P. and Wood, C. W., 2001, The design and experimental verification of heat exchanger accumulators used in small commercially available air conditioning systems, Int. J. Energy Research, Vol. 25, pp. 911-925 https://doi.org/10.1002/er.728
  3. Mei, V. C. and Chen, F. C., 1996, Experimental study of a liquid overfeeding window air conditioner, ASHRAE Transactions: Research, pp.63-67
  4. Navarro-Esbri, J., Cabello, R. and Torrella, E., 2005, Experimental evaluation of the internal heat exchanger influence on a vapour compression plant energy efficiency working with R22, R134a and R407C, Energy, Vol. 30, pp. 621-636 https://doi.org/10.1016/j.energy.2004.05.019
  5. Aprea, C., Ascani, M. and Rossi, F., 1999, A criterion for predicting the possible advantage of adopting a suction/liquid heat exchanger in refrigerating system, Applied Thermal Engineering, Vol. 19, pp.329-336 https://doi.org/10.1016/S1359-4311(98)00070-2