Abstract
In this paper the seismic performances of 4, 10, and 30-story staggered truss systems (STS) were evaluated by observing the force-displacement relationship up io failure. The results were compared with the seismic performance of conventional moment resisting frames and braced frames. According to the analysis results, the STS showed relatively satisfactory lateral load resisting capability. However, in the mid- to high-rise STS, plastic hinges formed first at the chords were transferred to vertical members of the vierendeel panels, which formed a week link and subsequently leaded to brittle collapse of the structure. Therefore to enhance the ductility of STS it would be necessary to reinforce the vertical bracing members of the virendeel panels so that the plastic hinges, once toned in cord members of a virendeel panel, spread out to virendeel panels of neighboring stories.
본 연구에서는 4층, 10층, 30층 스태거드 트러스 시스템 (STS)의 비탄성 정적해석에 의한 하중-변위 관계와 비탄성거동을 분석하고, 그 결과를 바탕으로 STS의 내진성능을 평가하였다. 또한 동일한 규모의 모멘트골조 및 가새골조의 거동과 비교함으로써 STS의 횡력 저항 능력을 파악하였다. 해석결과에 따르면, STS는 일반적으로 적용되는 구조시스템에 비하여 비교적 만족할 만한 내진성능을 보유하는 것으로 나타났다. 그러나 중층 이상의 STS에 있어서는 상대적으로 강성이 작은 비렌딜 패널 상.하현재에 소성변형이 발생한 후 인접한 수직 가새가 항복함으로써, 다른 층으로 소성변형이 전이되지 못하여 약층의 형성에 의한 취성적인 거동을 보인다. 그러므로 스태거드 트러스 시스템의 연성능력을 확보하기 위해서는 비렌딜 패널의 수직 가새를 보강하여 비렌딜 패널 상하현재에 발생한 소성변형을 다른 층의 비렌틸 패널로 유도하는 것이 필요하다.