Comparison of Transaxial Source Images and 3-Plane, Thin-Slab Maximal Intensity Projection Images for the Diagnosis of Coronary Artery Stenosis with Using ECG-Gated Cardiac CT

  • Choi, Jin-Woo (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Seo, Joon-Beom (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Do, Kyung-Hyun (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Choi, Sang-Il (Department of Radiology, Seoul National University College of Medicine) ;
  • Lee, Whal (Department of Radiology, Seoul National University College of Medicine) ;
  • Ko, Sung-Min (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Lee, Soo-Hyun (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Lee, Jin-Seong (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Song, Jae-Woo (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Song, Koun-Sik (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center) ;
  • Lim, Tae-Hwan (Department of Radiology, Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center)
  • 발행 : 2006.03.31

초록

Objective: We wanted to compare the transaxial source images with the optimized three plane, thin-slab maximum intensity projection (MIP) images from electrocardiographic (ECG)-gated cardiac CT for their ability to detect hemodynamically significant stenosis (HSS), and we did this by means of performing a receiver operating characteristic (ROC) analysis. Materials and Methods: Twenty-eight patients with a heart rate less than 66 beats per minute and who were undergoing both retrospective ECG-gated cardiac CT and conventional coronary angiography were included in this study. The contrast-enhanced CT scans were obtained with a collimation of $16{\times}0.75-mm$ and a rotation time of 420 msec. The transaxial images were reconstructed at the mid-diastolic phase with a 1-mm slice thickness and a 0.5-mm increment. Using the transaxial images, the slab MIP images were created with a 4-mm thickness and a 2-mm increment, and they covered the entire heart in the horizontal long axis (4 chamber view), in the vertical long axis (2 chamber view) and in the short axis. The transaxial images and MIP images were independently evaluated for their ability to detect HSS. Conventional coronary angiograms of the same study group served as the standard of reference. Four radiologists were requested to rank each image with using a five-point scale (1=definitely negative, 2=probably negative, 3=indeterminate, 4=probably positive, and 5=definitely positive) for the presence of HSS; the data were then interpreted using ROC analysis. Results: There was no statistical difference in the area under the ROC curve between transaxial images and MIP images for the detection of HSS (0.8375 and 0.8708, respectively; p>0.05). The mean reading time for the transaxial source images and the MIP images was 116 and 126.5 minutes, respectively. Conclusion: The diagnostic performance of the MIP images for detecting HSS of the coronary arteries is acceptable and this technique's ability to detect HSS is comparable to that of the transaxial source images.

키워드

참고문헌

  1. Rumberger JA. Noninvasive coronary angiography using computed tomography: ready to kick it up another notch [editorial]. Circulation 2002;106:2036-2038 https://doi.org/10.1161/01.CIR.0000037740.97150.43
  2. Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ, et al. Coronary angiography with multislice computed tomography. Lancet 2001;357:599-603 https://doi.org/10.1016/S0140-6736(00)04058-7
  3. Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Feyter PJ. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 2002;106:2051-2054 https://doi.org/10.1161/01.CIR.0000037222.58317.3D
  4. Kopp AF, Schroeder S, Kuettner A, Baumbach A, Georg C, Ohnesorge B, et al. Non-invasive coronary angiography with high resolution mutidetector-row computed tomography: results in 102 patients. Eur Heart J 2002;23:1714-1725 https://doi.org/10.1053/euhj.2002.3264
  5. Kopp AF, Schroeder S, Kuettner A, Heuchmid M, Georg C, Ohnesorge B, et al. Coronary arteries: retrospectively ECGgated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology 2001;221:683-688 https://doi.org/10.1148/radiol.2213010174
  6. Vogl TJ, Adolmaali ND, Diebold T, Engelmann K, Ay M, Dogan S, et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 2002;223:212-220 https://doi.org/10.1148/radiol.2231010515
  7. Gerber TC, Kuzo RS, Lane GE, O'Brien PC, Karstaedt N, Morin RL, et al. Image quality in a standardized algorithm for minimally invasive coronary angiography with multislice spiral computed tomography. J Comput Assist Tomogr 2003;27:62-69 https://doi.org/10.1097/00004728-200301000-00012
  8. Mahnken AH, Wildberger JE, Sinha AM, Dedden K, Stanzel S, Hoffmann R, et al. Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT. Acta Radiol 2003;44:302-309 https://doi.org/10.1034/j.1600-0455.2003.00057.x
  9. Addis KA, Hopper KD, Lyriboz TA, Liu Y, Wise SW, Kasales CJ, et al. CT angiography: in vitro comparison of five reconstruction methods. AJR Am J Roentgenol 2001;177:1171- 1176 https://doi.org/10.2214/ajr.177.5.1771171
  10. Hirai T, Korogi Y, Ono K, Murata Y, Takahashi M, Suginohara K, et al. Maximum stenosis of extracranial internal carotid artery: effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA. Radiology 2001;221:802-807 https://doi.org/10.1148/radiol.2213001746
  11. Rubin G, Dake MD, Napel S, Jeffrey RB, McDonnell CH, Sommer FG, et al. Spiral CT of renal artery stenosis: comparison of three-dimensional rendering techniques. Radiology 1994;190:181-189 https://doi.org/10.1148/radiology.190.1.8259402
  12. Berg MH, Manninen HI, Vanninen RL, Vainio RA, Soimakallio S. Assessment of renal artery stenosis with CT angiography: usefulness of multiplanar reformation, quantitative stenosis measurement, and densitometric analysis of renal parenchymal enhancement as adjuncts to MIP film rendering. J Comput Assist Tomogr 1998;22:533-540 https://doi.org/10.1097/00004728-199807000-00007
  13. Heath DG, Soyer PA, Kuszyk BS, Bliss DF, Calhoun PS, Bluemke DA, et al. Three-dimensional spiral CT during arterial portography: comparison of three rendering techniques. RadioGraphics 1995;15:1001-1011 https://doi.org/10.1148/radiographics.15.4.7569120
  14. Lu Bin, Dai RP, Jiang SL, Bai H, He S, Zhuang N, et al. Effects of window and threshold levels on the accuracy of threedimensional rendering techniques in coronary artery electronbeam CT angiography. Acad Radiol 2001;8:754-761 https://doi.org/10.1016/S1076-6332(03)80582-2
  15. Rensing BJ, Bongaerts A, van Geuns RJ, van Ooijen P, Oudkerk M, de Feyter PJ. Intravenous coronary angiography using electron beam computed tomography. Prog Cardiovasc Dis 1999;42:139-148 https://doi.org/10.1016/S0033-0620(99)70013-7
  16. Peter MA, van Ooijen P, Ho KY, Dorgelo J, Oudkerk M. Coronary artery imaging with multidetector CT: visualization issues. RadioGraphics 2003 Aug. Available from: URL: http://radiographics.rsnajnls.org/cgi/content/full/e16v1
  17. Pannu HK, Flohr TG, Corl FM, Fishman EK. Current concepts in multi-detector row CT evaluation of the coronary arteries: principles, techniques, and anatomy. RadioGraphics 2003;23:s111-125 https://doi.org/10.1148/rg.23si035514
  18. Soto JA, Munera F, Cardoso N, Guarin O, Medina S. Diagnostic performance of helical CT angiography in trauma to large arteries of the extremities. J Comput Assist Tomogr 1999;23:188-196 https://doi.org/10.1097/00004728-199903000-00005
  19. Sugahara T, Korogi Y, Hirai T, Hamatake S, Komohara Y, Okuda T, et al. CT angiography in vascular intervention for steno-occlusive diseases: role of multiplanar reconstruction and source images. Br J Radiol 1998;71:601-611 https://doi.org/10.1259/bjr.71.846.9849382
  20. Regenfus M, Ropers D, Achenback S, Schlundt C, Kessler W, Laub G, et al. Diagnostic value of maximum intensity projections versus source images for assessment of contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography. Invest Radiol 2003;38:200-206 https://doi.org/10.1097/00004424-200304000-00003
  21. Bae KT, Whiting BR. CT data storage reduction by means of compressing projection data instead of images: feasibility study. Radiology 2003;219:850-855