DOI QR코드

DOI QR Code

Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly

5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구

  • Published : 2006.02.01

Abstract

The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

Keywords

References

  1. Pettigrew, M. J. and Taylor, C. E., 2003, 'Vibration Analysis of Shell-and-tube Heat Exchangers: an Overview-Part 1: Flow, Damping, Fluidelastic Instability', 'Part 2: Vibration Response, Fretting-wear, Guidelines', Journal of the Fluids and Structures, 18, p. 469 and p. 485
  2. Lee, K. H., Kang, H. S., Yoon, K. H., Song, K. N., 2005, 'Experimental Study on the Vibration Characteristics of the 5x5 Rod Bundle Pre-characterization Test of the Test Bundle', Proceedings of the KNS Autumn Annual Meeting
  3. Au-Yang, M K, 2001, 'Flow-induced Vibration of Power and Process Plant Components', New York, ASME Press
  4. Song, K. N., Yoon, K. H., Kang, H. S. and Lee, K. H., 2005, 'Mechanical/Structural Characteristics Evaluation of the Spacer Grid Shapes for PWR fuels', Proceedings of the KSME Material and Fracture Division Annual Meeting, p. 31-37
  5. Cordelia Kaye Chandler, P. E., 2005, 'Methods of Determining a Damping Ratio From a Simple Impact Test', Proceedings of PVP2005, July 17-21, Colorado, Denver, USA, Paper Number 7104
  6. Kang, H. S. Lee, K. H., Yoon, K. H., Song, K. N. and Jung, Y. H., 2005, 'Investigation of the Damping for 5 $\times$ 5 Rod Bundle', Proceedings of the 12th ICSV, Portugal, Lisbon, Paper Number FP0305
  7. Lee, K. H., Kang, H. S., Yoon, K. H. and Song, K. N., 2005, 'Comparison of the Flow-Induced Vibration Characteristics of the 5x5 Rod Bundle with Optimized H Type Spacer Grids', Proceedings of the KSME Autumn Annual Meeting