Abstract
Ten types of steel bars having different Cr contents were embedded in concretes with chloride ion contents of 0.3, 0.6, 1.2, and $2.4kg/m^3$ to fabricate specimens assuming such deteriorative environments. After being carbonated to the reinforcement level, these concretes were subjected to corrosion-accelerating cycles of heating/cooling and drying/wetting. The time-related changes in the corrosion area and corrosion loss of the Cr-bearing rebars were then measured to investigate their corrosion resistance. The results revealed that in a deteriorative environment prone to both carbonation and chloride attack, corrosion resistance was evident with a Cr content of 7% or more and 9% or more in concretes with chloride ion contents of 1.2 and $2.4kg/m^3$, respectively.
중성화와 염해의 복합 열화 환경하의 콘크리트 내에서의 Cr강방식철근의 방식성을 평가하기 위하여 Cr함유율이 다른 10종류의 철근을 피복 두께 20mm 위치에 매입한 염화물 이온 함유량 0.3, 0.6, 1.2, $2.4kg/{m^3}$의 콘크리트 공시체를 제작하였다. 그 후 촉진 중성화 시험 및 고저온 건습 반복의 부식 촉진 시험 기간 중의 Cr강방식철근의 자연전위, 부식면적률, 부식감량률의 경시변화를 측정함으로써 각 부식 환경에 대한 Cr강방식철근의 방식성에 대하여 검토하였다. 그 결과, 중성화와 염해의 복합 열화 환경의 경우, 염화물 이온 함유량 $1.2kg/m^3$과 $2.4kg/m^3$에 대하여 각각 Cr함유율 7% 이상과 9% 이상의 Cr강방식철근에서 방식성이 확인되었다.