인공 환기가 필요한 환자에서 변형된 수동식 인공호흡기(Ambu®)의 유용성

Usefulness of modified ambu® in patients who need artificial ventilation

  • 하기수 (고려대학교 의과대학 소아과학교실) ;
  • 문일홍 (고려대학교 의과대학 소아과학교실) ;
  • 이희선 (고려대학교 의과대학 소아과학교실) ;
  • 신동한 (고려대학교 의과대학 소아과학교실) ;
  • 은소희 (고려대학교 의과대학 소아과학교실) ;
  • 은백린 (고려대학교 의과대학 소아과학교실) ;
  • 홍영숙 (고려대학교 의과대학 소아과학교실) ;
  • 이주원 (고려대학교 의과대학 소아과학교실)
  • Ha, Kee Soo (Department of Pediatrics, College of Medicine Korea University) ;
  • Moon, Il Hong (Department of Pediatrics, College of Medicine Korea University) ;
  • Lee, Hee Sun (Department of Pediatrics, College of Medicine Korea University) ;
  • Shin, Dong Han (Department of Pediatrics, College of Medicine Korea University) ;
  • Eun, So Hee (Department of Pediatrics, College of Medicine Korea University) ;
  • Eun, Baik-Lin (Department of Pediatrics, College of Medicine Korea University) ;
  • Hong, Young Sook (Department of Pediatrics, College of Medicine Korea University) ;
  • Lee, Joo Won (Department of Pediatrics, College of Medicine Korea University)
  • 투고 : 2006.08.16
  • 심사 : 2006.09.11
  • 발행 : 2006.11.15

초록

목 적 : 혼수 환자는 원인에 상관없이 혼수 상태가 오래 지속되었을 경우 회복불능의 상태로 될 수 있기 때문에 원인을 신속하게 발견하여 치료하는 것이 중요하다. 그 중 MRI 검사는 혼수 환자의 원인을 감별하는데 중요하나 자발호흡이 없는 환자에게 MRI 검사 시 여러 가지 제한점으로 인해 그 시행이 어려웠다. 저자들은 변형된 수동식 인공호흡기를 이용하여 일정 거리에서 환자에게 전달되는 환기량을 유지하면서 MRI 검사가 가능한지 알아보고 안정성을 확인하고자 본 연구를 실시하였다. 방 법 : 특별히 고안한 장치는 self-inflating bag type의 수동식 인공호흡기에 PVC 관을 연결하고 그 끝을 환자의 기도와 연결하여 만든 비교적 간단한 장치이다. 또한 안정성을 확인하기 위하여 기계식 인공호흡기를 이용하여 PVC 연결 관의 길이와 직경 및 일회호흡량(tidal volume)을 변화시켰을 경우 TVe, MVe, PIP를 측정하여 환기에 미치는 영향에 대해 알아보았다. 결 과 : 15 mm, 25 mm 직경의 2가지 종류의 PVC 연결 관을 이용하여 TVi를 변화시킴과 동시에 관의 길이를 1, 2, 3 m로 증가시킴에 따라 TVe, MVe, PIP 값을 측정하였으며, 그 결과 TVe, MVe 값은 대조군과 비교해 차이가 없었고 PIP 값은 TVi가 증가함에 따라, 관의 길이가 늘어남에 따라 의미 있는 증가를 보였다(P<0.05). 또한 관의 길이, TVi에 관계없이 PIP 값은 PVC 연결 관의 직경과 음의 상관관계를 보였다. 즉 관의 직경이 작을수록, 관의 길이가 길어질수록, 일회호흡량이 증가할수록, 환기량을 유지하기 위한 PIP값은 증가하였다. 5명의 환자들을 대상으로 이러한 방법을 이용하여 MRI 검사를 시행하였으며 성공적으로 검사를 실시하였다. 결 론 : 저자들이 고안한 수동식 인공호흡기를 이용한다면 자발호흡이 불안정하여 MRI 검사를 시행하지 못했던 많은 환자들에게 더 많은 검사의 기회가 주어질 것이며 환자의 질환을 진단하는데 많은 도움을 줄 것이다.

Purpose : The comatose mentality can be catastrophic, especially if the condition is severe or the duration is prolonged. Therefore, delayed diagnosis can result in a poor outcome or death. The best radiologic modality to differentiate from cerebral lesions in patients suffering from cerebral diseases is magnetic resonance imaging (MRI) rather than computed tomography (CT). Special apparatuses with metal materials such as ventilators, and cardiac pacemakers belonging to patients cannot be located in the magnetic field. We aimed to exhibit the possibility of examining MRI, maintaining ventilation at a relative long distance by means of modified $Ambu^{(R)}$. Methods : Self-inflating bags as a sort of a manual ventilator, connected with relatively long extension tubes instead of mechanical ventilators, were adopted to obtain MRI. PVC (polyvinyl chloride) extension tubes had different lengths and diameters. Lengths were 1, 2, and 3 cm and diameters were 15, and 25 mm. The work of breathing and expiratory changes of expiratory tidal volume (TVe), minute volume of expiration (MVe), peak inspiratory pressure (PIP) were measured by use of the mechanical ventilator, $Servoi^{(R)}$, as the alteration of TVi (inspiratory tidal volume), extension tube lengths and diameters with other values fixed. Results : Measured TVe and MVe by ventilator were the same values with control at every TVi, regardless of extension tube lengths and diameters, but PIP were increased with the rise of TVi, tube lengths, with decline of tube diameters, these were statistically significant. Conclusion : MRI examination can be carried out with a self-inflating bag connected with an extension tube at a long distance in patients who need artificial ventilation.

키워드

참고문헌

  1. Kuhn JP, Slovis TL, Haller JO. Caffey's pediatric diagnostic imaging. 10th ed. St. Louis : Mosby Co, 1999:319-20
  2. Martin RJ, Fanaroff AA, Walsh MC. Neonatal-perinatal medicine. 8th ed. St. Louis : Mosby Co, 2006:483-508
  3. Chang LT. A method for attenuation correction in radionuclide computed tomography. IEEE Trans Nucl Sci 1978;25:638-43 https://doi.org/10.1109/TNS.1978.4329385
  4. Yudd AP, Van Heertum RL, Masdeu JC. Interventions and functional brain imaging. Semin Nucl Med 1991;21:153-8 https://doi.org/10.1016/S0001-2998(05)80052-2
  5. Hunter JV, Wang ZJ. MR spectroscopy in pediatric neuroradiology. Magn Reson Imaging Clin N Am 2001;9:165-89
  6. Edwards MK, Barnes PD. Pediatric neuroimaging. Neuroimaging Clin N Am 1999;9:1-226
  7. American thoracic Society. Standardization of spirometry. Am J Respir Crit Care Med 1995; 15:1107-36
  8. European respiratory society. Lung volumes and forced ventilatory flows. Eur Respir J 1993;6:5-40 https://doi.org/10.1183/09041950.005s1693
  9. Dark DS, Pingleton SK, Kerby GR. Hypercapnea during weaning a complication of nutritional support. Chest 1985;88:141-5 https://doi.org/10.1378/chest.88.1.141
  10. Field S, Kelly SM, Maklem PT. The oxygen cost of breathing in patients with cardio-respiratory disease. Am Res Respir Dis 1982;9:126-27
  11. Foster RE, Dubois AB, Briscoe WA, Fisher AB. The lung. 3rd ed. Chicago : Year book medical publishers 1986:115-6
  12. Goldsmith JP, Karotkin EH. Assisted ventilation of the neonate. 3rd ed. Philadelphia : W.B. Saunders Co, 1996:21
  13. Heaf DP, Helms P, Gordon I. Postural effects on gas exchanges in infants. N Engl J Med 1983;308:1505 https://doi.org/10.1056/NEJM198306233082505
  14. Polin RA, Fox WW. Fetal and neonatal physiology. 1st ed. Philadelphia : W.B. Saunders Co, 1992:771
  15. Allwood AC, Madar RJ, Baumer JH, Readdy L, Wright D. Changes in resuscitation practice at birth. Arch Dis Child Fetal Neonatal Ed 2003;88:375-9 https://doi.org/10.1136/fn.88.5.F375
  16. Hoskyns EW, Milner AD, Hopkin IE. A simple method of face mask resuscitation at birth. Arch Dis Child 1987;62:376-8 https://doi.org/10.1136/adc.62.4.376
  17. Cole AF, Rolbin SH, Hew EM, Pynn S. An improved ventilator system for delivery-room management of the newborn. Anesthesiology 1979;51:356-8 https://doi.org/10.1097/00000542-197910000-00019
  18. Ganga-Zandzou PS, Diependaele JF, Storme L. Is Ambu ventilation of newborn infants a simple question of fingertouch. Arch Pediatr 1996;3:1270-2 https://doi.org/10.1016/S0929-693X(97)85940-4
  19. Finer NN, Rich W, Craft A, Henderson C. Comparison of methods of bag and mask ventilation for neonatal resuscitation. Resuscitation 2001;49:299-305 https://doi.org/10.1016/S0300-9572(01)00311-2
  20. Kanter RK. Evaluation of mask-bag ventilation in resuscitation of infants. Am J Dis Child 1987;141:761-3
  21. Murray JF. The normal lung. 1st ed. Philadelphia : W.B. Saunders Co, 1976:1