Usefulness of the transcutaneous bilirubinometer during phototherapy in neonatal jaundice

신생아 황달에서 광선치료 동안에 경피적 빌리루빈 측정기의 유용성

  • Lee, Yung Kwun (Department of Pediatrics, Cheil General Hospital & Women's Healthcare, Sungkyunkwan University, School of Medicine) ;
  • Kim, Kyung Ah (Department of Pediatrics, Cheil General Hospital & Women's Healthcare, Sungkyunkwan University, School of Medicine) ;
  • Ko, Sun Young (Department of Pediatrics, Cheil General Hospital & Women's Healthcare, Sungkyunkwan University, School of Medicine) ;
  • Lee, Yeon Kyung (Department of Pediatrics, Cheil General Hospital & Women's Healthcare, Sungkyunkwan University, School of Medicine) ;
  • Shin, Son Moon (Department of Pediatrics, Cheil General Hospital & Women's Healthcare, Sungkyunkwan University, School of Medicine)
  • 이용권 (성균관대학교 의과대학 제일병원 소아과) ;
  • 김경아 (성균관대학교 의과대학 제일병원 소아과) ;
  • 고선영 (성균관대학교 의과대학 제일병원 소아과) ;
  • 이연경 (성균관대학교 의과대학 제일병원 소아과) ;
  • 신손문 (성균관대학교 의과대학 제일병원 소아과)
  • Received : 2006.06.20
  • Accepted : 2006.08.22
  • Published : 2006.12.15

Abstract

Purpose : We studied the usefulness of transcutaneous bilirubinometers in follow-up of bilirubin levels during phototherapy in neonatal jaundice patients. Methods : Transcutaneous bilirubin (TcB) was measured twice per day on 90 neonatal jaundice patients without risk factors of jaundice by transcutaneous bilirubinometer JM-103(Minolta/Hill-Rom Air-shields, Japan). TcB was measured simultaneously on the patched-forehead (TcB-PF), patchedchest(TcB-PC), unpatched-forehead (TcB-UF) and unpatched-chest (TcB-UC) of infants with neonatal jaundice. Plasma bilirubin (PB) was measured by American Optical bilirubinometer (American Optical Co, Buffalo, USA) within 30 minutes after transcutaneous bilirubinometer measurement. Each TcB was compared with PB. Results : In the study group, the mean gestational age was $38.6{\pm}1.3wk$, the mean birthweight was $3,207.0{\pm}472.1g$, the mean age at start of phototherapy was $4.9{\pm}0.9days$ and the mean duration of phototherapy was $1.3{\pm}0.6days$. The correlation between TcB and PB level was observed. The correlation between TcB of the patched part (TcB-PF, TcB-PC) and PB was more significant than that of the unpatched part (TcB-UF, TcB-UC) and PB. The most significant correlation was between PB and TcB-PC. Conclusion : TcB was useful in the follow-up of jaundice during phototherapy as well the screening of jaundice in neonatal jaundice patients. TcB of patched-chest area was the most reliable site in transcutaneous bilirubinometer examination in neonatal jaundice patients.

목 적 : 신생아 황달은 신생아기에 가장 흔한 질환으로 핵황달 및 사망까지의 심각한 후유증을 유발할 수 있기 때문에 신속하고 정확한 빌리루빈 농도의 측정과 치료가 중요하다. 따라서 신생아 황달의 진단에서 빌리루빈 측정법 중 경피적 빌리루빈 측정기의 개발로 신생아 황달의 선별법으로 사용되고 있다. 그러나 광선치료 동안에 경피적 빌리루빈 측정기의 유용성이 연구되지 않아 이에 저자들은 광선치료 동안에 측정하는 신체의 부위별 TcB와 PB의 상관관계를 조사해서 경피적 빌리루빈 측정기의 유용성을 알아보고자 본 연구를 시행하였다. 방 법 : 2005년 6월부터 8월까지 제일병원 신생아실에서 광선치료를 받는 황달의 임상적 위험성(미숙아, Rh및 ABO 부적합증, 간손상 등 다른 합병증)이 없는 신생아 90명을 대상으로 경피적 빌리루빈 측정기인 JM-103을 사용하여 광선치료 시작전 이마와 흉골 중앙부에 opaque patch을 붙이고 광선치료 동안에 opaque patch 부위와 바로 인접한 부위에서 TcB를 측정하였다. TcB 측정시 각각 3회씩 측정하여 평균치를 TcB로 하였으며, 경피적 빌리루빈 측정기로 측정한 시각으로부터 30분 이내에 발뒤꿈치를 천자하여 PB를 측정하여 측정 부위간 TcB와 PB의 상관관계를 비교 관찰하였다. 결 과 : 대상에 포함된 신생아는 황달의 임상적 위험성(미숙아, Rh 및 ABO 부적합증, 간손상 등 다른 합병증)이 없는 신생아를 대상으로 하였고 신생아의 평균 재태주령은 $38.6{\pm}1.3$주였고 평균 출생 체중은 $3,207.0{\pm}472.1g$이었고 광선치료 시작 시기는 평균 $4.9{\pm}0.9$일이고 평균 광선치료 기간은 $1.3{\pm}0.6$일이었다. 대상 신생아의 광선치료 시작전 PB와 patch 붙인 흉골 부위의 TcB, patch 붙인 이마 부위의 TcB, 흉골 부위의 TcB, 이마 부위의 TcB 결과는 각 부위간에 유의한 상관관계를 보였다. 광선치료 동안에 각 측정부위별(TcB-UF, TcB-UC, TcB-PF, TcB-PC)와 PB는 의미있는 상관관계를 나타내었고 opaque patch를 붙인 부위가 인접한 부위보다 PB와 의미 있는 상관관계를 나타내었으며 TcB-PC가 TcB-PF보다 더욱 더 PB와 의미 있는 상관관계를 나타내었으며 일치도가 높았다. 결 론 : 본 연구의 결과로 경피적 빌리루빈 측정기는 신생아 황달의 선별검사 방법뿐 아니라 광선치료 동안에도 추적검사 측정법으로 사용하기에 적절하다고 생각되며 사용하는 기관에서 자기고유의 회귀직선을 작성하여 사용한다면, 신생아의 몸에 침해를 가하지 않고 편리하고 신속하게 신생아 과빌리루빈혈증 진단과 추적검사에 유용하게 사용될 수 있으리라 생각된다.

Keywords

References

  1. Kliegman RM, Behrman RE, Jenson HB. Nelson textbook pediatrics. 17th ed. Philadelphia : WB Saunders Co, 2004: 592-6.
  2. Tan KL. Glucose-6-phosphate dehydrogenase status and neonatal jaundice. Arch Dis Child 1981;56:574-7
  3. Brown W, Wong HB. Ethnic group differences in plasma bilirubin levels of full-term healthy Singapore newborns. Pediatrics 1965;36:745-9
  4. Osborn LM, Reiff MI, Bolus R. Jaundice in the full-term neonate. Pediatrics 1984;73:520-25
  5. Jung MJ, Seo YJ, Kim JD, Shin MH, Oh JS. Determination of bilirubin concentration in the jaundiced korean newborn infants with transcutaneous bilirubinometer. J Korean Pediatr Soc 1983;26:21-9
  6. Su KH. Comparative evaluation between 4 methods for determination of bilirubin concentration in the jaundiced newborn infants. J Korean Pediatr Soc 1979;22:11-8
  7. Kim HS. Kim JK, Lee K. Determination of bilirubin concentration in the jaundiced newborn infants with A.O. bilirubinometer. J Korean Pediatr Soc 1982;22:29-31
  8. Kramer LI. Advancement of dermal icterus in the jaundiced newborn. Am J Dis Child 1969;118:454-8
  9. Abril Martin JC, Aguilar Rodriguez L, Albinana Cilveti J. Flatfoot and calcaneal deformity secondary to osteomyelitis after neonatal heel puncture. J Pediatr Orthop Part B 1999; 8:122-4 https://doi.org/10.1097/00009957-199904000-00012
  10. Canale ST, Manugian AH. Neonatal osteomyelitis of the oscalcis : a complication of repeated heel punctures. Clin Orthop 1981;156:178-82
  11. Yamanouchi I, Yamauchi Y, Igarashi I. Transcutaneous bilirubinometry : preliminary studies of noninvasive transcutaneous bilirubinometer in the Okayama National Hospital. Pediatrics 1980;65:195-202
  12. Wiliams RA, Pitts LL, Weinerath BL, Dimmette PM. Clinical and laboratory evaluation of the American Optical bilirubinometers. J Pediatr 1971;77:671-8
  13. Hegyi T, Hiatt IM, Indyk L. Transcutanous bilirubinometry. I. Correlations in term infants. J Pediatr 1981;96:454-7
  14. Hegyi T. Transcutaneous bilirubinometry : A new light on an old subject. Pediatrics 1982;69:124-5
  15. Gosset IH. A perspex icterometer for neonates. Lancet 1960;1:87-8 https://doi.org/10.1016/S0140-6736(02)83667-4
  16. Hanneman RE, Dewitt DP, Wiechel JF. Neonatal serum bilirubin from skin reflectance. Pediatr Res 1978;12:207-10 https://doi.org/10.1203/00006450-197803000-00009
  17. Selard C, Brown GE. The spectrophotometric analysis of the color of the skin. Arch Intern Med 1926;38:816-31 https://doi.org/10.1001/archinte.1926.00120300133011
  18. Jacques JA, Kuppenheim HF. Spectral reflectance of human skin in the region 235-1,000nm. J Appl Physiol 1955;7:523-8 https://doi.org/10.1152/jappl.1955.7.5.523
  19. Maisels MJ, Conrad S. Transcutaneous bilirubin measurements in full-term infants. Pediatrics 1982;70:464-7
  20. Bhutani VK, Johnson L, Gourley G. Noninvasive measurement of total serum bilirubin by multi-wavelength spectral reflectance by Bili-Check in newborn patients. Pediatr Res 1998;43:167-71
  21. Bhutani VK, Gourley GR, Adler Keramer B, Dalin C, Johnson LH. Non-invasive measurement of total serum bilirubin in multiracial predischarge newborn population to asses the risk of severe hyperbilirubinemia. Pediatrics 2000;106:17-22 https://doi.org/10.1542/peds.106.2.e17
  22. Choi BM. Recent advances of medical apparatus in fields of neonatal care. J Korean Pediatr Soc 2002;45(1 Suppl): 87S-88S
  23. An JR, Lee HC, Kim KA, Ko SY, Lee YK, Shin SM. Usefulness of the transcutaneous bilirubinometer in neonatal jaundice. Korean J Pediatr 2004;47:1287-92
  24. Rubaltelli FF, Carli M. The effect of light on cutaneous bilirubin. Biol Neonate 1971;18:457-62 https://doi.org/10.1159/000240388
  25. Hanneman RE, Schreiner RL, Dewitt DP, Norris SA. Evaluation of the Minolta bilirubinometer as a screening device in white and black infants. Pediatrics 1982;69:107-9
  26. Tan KL, Dong F. Transcutaneous bilirubinometry during and after phototherapy. Acta Pediatr 2003;92:327-31 https://doi.org/10.1080/08035250310009257