대학 도서관 건물 리모델링에 따른 실내공기질 영향 평가

Impact Assessment of Remodeling Works on Indoor Air Quality in a University Library Building

  • 백성옥 (영남대학교 건설환경공학부) ;
  • 박대진 (영남대학교 건설환경공학부) ;
  • 박선영 (영남대학교 건설환경공학부) ;
  • 이여진 (영남대학교 건설환경공학부)
  • Baek, Sung-Ok (School of Civil and Environmental Engineering, Yeungnam University) ;
  • Park, Dae-Gwon (School of Civil and Environmental Engineering, Yeungnam University) ;
  • Park, Sun-Young (School of Civil and Environmental Engineering, Yeungnam University) ;
  • Lee, Yeo-Jin (School of Civil and Environmental Engineering, Yeungnam University)
  • 발행 : 2006.12.31

초록

Recently, there have been a large number of remodeling (or renovation) works in old buildings in urban areas. Compared to new buildings, environmental risk might be more significant in such buildings where remodeling works are going on, since some parts of the building may still be in service for people. This study was carried out to investigate the impacts of remodeling works on the indoor air quality (IAQ) of a large building (a 22 stories university library). Indoor air monitoring was conducted during and after the remodeling works every two weeks for a one year period, and target compounds included BTEX, styrene, TVOC, carbonyl compounds such as formaldehyde and acetaldehyde. $CO,\;CO_2,\;PM_{10}$, and $PM_{2.5}$. Overall, the IAQ appeared to be recovered within two months after the remodeling works. However, in some places, concentrations of formaldehyde, toluene, xylene. and ethylbenzene showed higher levels even after works than those during the works. The results indicate that painting, glues and office furnitures are major sources of aromatic VOCs and formaldehyde. Therefore, in order to decrease the concentrations of toxic VOCs, the use of environmental-friendly building materials is strongly recommended during the remodeling works. In addition, IAQ control and management scheme (for example, baking the inside of the building) should be taken into consideration before reopening the buildings.

키워드

참고문헌

  1. 김강석, 이희선, 공성용, 구현정 (2001) 실내공기오염에 대한 국민의식 조사와 정책 방안 연구. 한국환경정책.평가연구원 연구보고서 KEI/2002/RE-07, 203pp
  2. 백성옥, 김미현, 김수현, 박상곤(2002) 국내 대기 중 독성 휘발성 유기화합물의 오염특성(I) - 측정 방법론 평가, 환경독성학회지, 17(2), 95-107
  3. 백성옥, 김미현, 서영교 (2003) 발생원 유형에 따른 공기 중 휘발성 유기화합물의 비산배출 특성 평가, 한국대기환경학회지, 19(4), 363-376
  4. 정부 관계부처 합동(2004) 실내공기질 관리 기본계획 보고서, 149pp
  5. 한국페인트잉크공업협동조합 (1996) VOC 배출원별 배출량 산정 및 저감기술연구, 페인트와 잉크, 102, 69-81
  6. 한국대기환경학회(2004) 실내공기질 정책 및 관측기술, 151 pp
  7. 佐佐木裕价(1998) 有害大氣汚染物質對策をめぐる最近の動向, 資源環境對策, 34(12), 47-58
  8. Bianchi, A.P. and M.S. Varney (1993) Sampling and analysis of volatile organic compounds in estuarine air by gas chromatography and mass spectrometry, J. of Chromatography, 643, 11-23 https://doi.org/10.1016/0021-9673(93)80536-H
  9. Sirju, A.P. and P.B Shepson (1995) Laboratory and field investigation of the DNPH cartridge technique for the measurement of atmospheric carbonyl compounds, Environ. Sci. Technol., 29(2), 384-392 https://doi.org/10.1021/es00002a014
  10. US EPA (1997) Compendium of methods TO-17 determination of toxic organic compounds in ambient air, 2nd Ed., EPA U.S.A. 1-51
  11. WHO (2000) Guidelines for Air Quality, WHO, Geneva, 190pp