DOI QR코드

DOI QR Code

The Filling Balance of LDPE/ABS/PA6,6 Resin in Variable-Runner-System

가변러너시스템에서 LDPE/ABS/PA6,6 수지의 충전균형

  • 박형필 (한국생산기술연구원 정밀금형팀) ;
  • 차백순 (한국생산기술연구원 정밀금형팀) ;
  • 강중근 (아주대학교 기계공학과) ;
  • 이병옥 (아주대학교 기계공학과)
  • Published : 2006.12.01

Abstract

During the injection molding process an excessive packing can occur in the smaller volume cavity because of volumetric difference of the family-mold. It causes warpage by increased residual stress in the product and flesh by over packing. In this study, we used a variable-runner system for the filling balance of the cavities by changing the cross-sectional area of a runner, and confirmed the filling imbalance by temperature and pressure sensors. We carried out experiments to examine the influence of types of resins such as LDPE/ABS/PA6,6 on the filling balancing of the system, in order to help mold designers, who can easily adopt the variable-runner system to their design. We also examined filling imbalance in the system with CAE analysis.

Keywords

References

  1. J. P. Beaumont, J. H. Young, 1997, Mold filling imbalances in geometrically balanced runner systems, Journal of Injection Molding Technology, Vol. 1, No.3, pp. 133-135
  2. Y. D. Jeong, 2006, Development of new runner system for filling balance in multi cavity injection mold, Transactions of Materials Processing, Vol. 15, No. 1, p. 42 https://doi.org/10.5228/KSPP.2006.15.1.042
  3. M. Wolbert, B. Zore, 2005, Shear imbalance effects on gas distribution in gas-assist injection molding, ANTEC2006, Vol. 3, pp. 3774-3777
  4. J. P. Coulter, 2003, Cavity specific control of melt flow during injection molding processes, Conference proceedings of ASME International Mechanical Engineering Congress & Exposition, Washington, D.C., Vol. 3
  5. P. Kennedy, 1995, Flow analysis of injection molds, Hanser & Gardner Publications Inc., New York, Cincinnati
  6. C. Collins, 1999, Monitoring cavity pressure perfects injection molding, Assembly Automation, Vol. 19, No.3, pp. 197-202 https://doi.org/10.1108/01445159910280056
  7. M. R. Karmal, W. I. Patterson, N. Conley, D. Abu Fara, G. Lohfink, 1987, Dynamics and control of pressure in the injection molding of thermoplastics, Polymer Engineering and Science, Vol. 27, pp. 1403-1410 https://doi.org/10.1002/pen.760271809
  8. D. Kazmer, P. Barkan, 1997, The process capability of multi-cavity pressure control for the injection molding process, Polymer Engineering and Science, Vol. 37, No. 11, pp. 1880-1891 https://doi.org/10.1002/pen.11838
  9. S. Orzechowski, A. Parism, C. Dobbin, 1998, A Process Monitoring and Control System for Injection Molding using Nozzle-based Pressure and Temperature Sensors, ANTEC98, Vol. 1, pp. 733-742
  10. W. I. Patterson, 1990, Mold temperature measurement and control, ANTEC90, pp. 227-232