DOI QR코드

DOI QR Code

Cycle Analysis on LNG Boil-off Gas Re-Liquefaction Plant

  • Chin, Y.W. (Department of Mechanical Engineering, Korea University of Technology and Education)
  • Published : 2006.11.30

Abstract

Cycle analysis was performed in order to find the optimum design point of the LNG Boil-off gas re-liquefaction system. Thermodynamic analysis revealed the system could be defined by three state variables. Thus the system performance could be described by the three cold endpoint temperatures of the three-pass heat exchanger. This enabled us to investigate the cycle performance in terms of the heat exchanger parameters. To get access to the cycle states of higher system performances, larger heat exchangers were found necessary. Also the thermal pinch in cryogenic heat exchangers was found to act as a limiting factor to the system performance.

Keywords

References

  1. O. M. Mate and A. M. Diaz, 'Reliquefaction systems for marine applications,' World Maritime Conference 17, pp. 1-15, 2003
  2. H. S. Kim, 'Economical analysis on the size and propulsion system of LNG carrier,' Technical Trend of the Gas Industry, KOGAS, Vol. 17, pp. 69-76
  3. R. F. Barron, Cryogenic System, 2nd ed., Oxford University Press: New York, pp. 357-362, 1985
  4. R. W. Haywood, Analysis of Engineering Cycles, 3rd ed., Pergamon Press: New York, pp. 152-168, 1990
  5. J. H. Baek and H. M. Chang, 'Cycle Analysis of 2-Stage Expansion Claude Refrigerator with Turboexpanders, ' Journal of Sarek, vol. 6, no.2, pp. 130-139, 1994