상악 구치부 임플랜트 보철수복시 치관/치근비에 따른 응력 분포에 대한 유한 요소 분석

FINITE ELEMENT ANALYSIS ON MAXILLARY MOLAR IMPLANT UNDER DIFFERENT C/R RATIO

  • 김진호 (경희대학교 치과대학 치과보철학교실) ;
  • 김형섭 (경희대학교 치과대학 치과보철학교실) ;
  • 최대균 (경희대학교 치과대학 치과보철학교실) ;
  • 권긍록 (경희대학교 치과대학 치과보철학교실)
  • Kim, Jin-Ho (Department of Prosthodontics, Division of Dentistry, Graduate School, Kyung Hee University) ;
  • Kim, Hyung-Seob (Department of Prosthodontics, Division of Dentistry, Graduate School, Kyung Hee University) ;
  • Choi, Dae-Gyun (Department of Prosthodontics, Division of Dentistry, Graduate School, Kyung Hee University) ;
  • Kwon, Kung-Rock (Department of Prosthodontics, Division of Dentistry, Graduate School, Kyung Hee University)
  • 발행 : 2006.10.31

초록

Statement of the problem: In cases of low bone level in maxilla followed by extraction due to severe periodontitis or enlarged maxillary sinus, crown-root ratio of implant prosthesis will increase. The prognosis of these cases is not good as expected. Purpose : The purpose is to compare stress distribution due to crown-root ratio and effect of splinting between two implants in maxillary molar area under different loads Material and methods: Using ITI($4.1{\times}10$ mm) implant. two finite element models were made(model S: two parallel implants, model A: one of two is 20 degree inclined). Each model was designed in different crown-root ratio(0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it splinted or non-splinted clinical situations. After that, 300 N force was loaded to each model in four ways.(load 1 : middle of occlusal table, load 2 : middle of buccal cusp, load 3 : middle of lingual cusp, load 4 : horizontal load to middle of buccal cusp), and stress distribution was analyzed. Results: On all occasions, stress was concentrated on neck of implant near cortical bone. In the case of inclined implant, stress was increased compared with parallel implants. Under load 1, 2, 3, stress was not increased even when crown-root ratio increases, but under load 4, when crown-root ratio increases, stress also increased. And more stress was concentrated under load 1 than load 2, 3. When crown-root ratio was same, stress under load 1, 2, 3 decreased when splinting, but under load 4, stress did not really decrease. Conclusion: Under vertical load, stress distribution related to crown-root ratio did not change. But under horizontal load, stress increased as crown-root ratio increases. Under vertical load, splinting decreased stress but under horizontal load, effect of splinting was decreased as condition of implant changes for the worse such as increase of crown-root ratio, inclined implant.

키워드

참고문헌

  1. Branemark PI, Breine D, Lindstrom J, Adell R, Hansson BO, Ohlsson A. Intra-osseousanchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969:3:81-100 https://doi.org/10.3109/02844316909036699
  2. Isidor F. Loss of osseointegration cause by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 1996:7:143-52
  3. Himmlova L, Dostalova T. Influence of implant length and diameter on stress distribution:A finite element analysis. J Prosthet Dent 2004:91:20-5 https://doi.org/10.1016/j.prosdent.2003.08.008
  4. Wiskott HW, Belser UC. Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone. Clin Oral Implants Res 1999:10:429-44
  5. Davarpanah M, Martinez H, Tecucianu JF. Apical-coronal implant position: recent surgical proposals technical note. Int J Oral Maxillofac Implants 2000:15:865-72
  6. Yang HS, Lang LA, Felton DA. Finite element stress analysis on the effect of splinting in fixed partial dentures. J Prosthet Dent 1999:81:721-8 https://doi.org/10.1016/S0022-3913(99)70113-7
  7. Ishigaki S, Nakano T, Yamada S, Nakamura T, Takashima F. Biomechanical stress in bone surrounding an implant under simulated chewing. Clin Oral Impl Res 2003:14:97-102
  8. Eskitascioglu G, Usumez A. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study. J Prosthet Dent 2004:91:144-50 https://doi.org/10.1016/j.prosdent.2003.10.018
  9. Ismail YH, Pahountis LN, Fleming JF. Comparison two-dimensional and three-dimensional finite element of a blade implant. J Oral Implantol 1987:4:25-31
  10. Timoshenko S, Young DH. Elements of strength of materials. 5th ed. Florence: Wadsworth : 1968. p.377-90
  11. Papavasiliou G, Kamposiora P, Bayne SC, Felton DA. Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prostheses type, and loading during function. J Prosthet Dent 1996:76:633-40 https://doi.org/10.1016/S0022-3913(96)90442-4
  12. Penny RE, Kraal JH. Crown-to-root ratio : Its significance in restorative dentistry. J Prosthet Dent 1979:42:34-38 https://doi.org/10.1016/0022-3913(79)90327-5
  13. Johnston JE, Phillips RW, Dykema RW. Modern Practice in crown and bridge prosthodontics, 3rd ed. 1971
  14. Reynolds JM. Abutment selection for fixed prosthodontics. J Prosthet Dent 1968:19:488-94
  15. Dykema RW. Fixed partial prosthodontics. J Tenn Dent Assoc 1962:43:309
  16. Leonard Krekmanov. Placement of posterior Mandibular and Maxillary implants in patients with severe bone deficiency: a clinical report of procedure. Int J Oral Maxillofac Implants 2000:15:722-730
  17. Glickman I, Stein S, Smulow JB. The effect of increased functional forces upon the periodontium of splinted and non-splinted teeth. J Periodontol 1961:32:290-9 https://doi.org/10.1902/jop.1961.32.4.290
  18. Glickman I, Roeber FW, Brion M, Pameijer JHN. Photoelastic analysis of internal stress in periodontium created by occlusal forces. J Periodontol 1970:41:41-3 https://doi.org/10.1902/jop.1970.41.41.41
  19. Wang TM, Leu LJ, Wang J, Lin LD. Effect of prosthesis materials and prosthesis splinting on peri-implant bone stress around in poor quality bone.: a numeric analysis. Int J Oral Maxillofac Implants 2002:17:231-7
  20. Duyck J, Naert I, Van OH, Ronold HJ, Vander SJ, Ellingsen JE. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Implants Res 2001:12:207-18 https://doi.org/10.1034/j.1600-0501.2001.012003207.x
  21. Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994:9:345-60
  22. Ichikawa T, Kanitani H, Kawamato N, Matsumato N, Wigianto R. Influence of bone quality on the stress distribution. an in vitro experiment. Clin Oral Implants Res 1997:16:6-11
  23. Matsushita. Y. Two-dimensional FEM Analysis of Hydroxyapatite Implants: Diameter Effects on Stress Distribution. J Oral Implantol 1990:16:6-11
  24. Meijer HJ, Starmans FJ, Steen WH, Bosman F. Loading conditions of endosseous implants in an edentulous human mandible: a three-dimensional, finite-element study. J Oral Rehabil 1996:23:757-63 https://doi.org/10.1046/j.1365-2842.1996.d01-185.x
  25. Barbier L, Vander SJ, Krzesinski G, Schepers E, Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandibule of the dog. J Oral Rehabil 1998:25:847-858 https://doi.org/10.1046/j.1365-2842.1998.00318.x
  26. Choi MH, Kang JS, Boo SB, Oh SH, An OJ, Kang DW. Finite element stress analysis according to the point and surface occlusal loads on the implant prosthesis. J of Korean Academy Stomatognathic Function and Occlusion 2004:20:83-94
  27. Weinberg LA. Reduction of implant loading with therapeutic biomechanics. Implant Dent 1998:7:277-85 https://doi.org/10.1097/00008505-199807040-00005
  28. Zhang JK, Chen ZQ. The study of effects of the elastic modulus of the materials substitute to human hard tissues on the mechanical state in the implant-bone interface by three-dimensional anisotropic finite element analysis. West China J Stomatol 1998:16:274-278