참고문헌
- Branemark PI, Breine D, Lindstrom J, Adell R, Hansson BO, Ohlsson A. Intra-osseousanchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969:3:81-100 https://doi.org/10.3109/02844316909036699
- Isidor F. Loss of osseointegration cause by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 1996:7:143-52
- Himmlova L, Dostalova T. Influence of implant length and diameter on stress distribution:A finite element analysis. J Prosthet Dent 2004:91:20-5 https://doi.org/10.1016/j.prosdent.2003.08.008
- Wiskott HW, Belser UC. Lack of integration of smooth titanium surfaces: a working hypothesis based on strains generated in the surrounding bone. Clin Oral Implants Res 1999:10:429-44
- Davarpanah M, Martinez H, Tecucianu JF. Apical-coronal implant position: recent surgical proposals technical note. Int J Oral Maxillofac Implants 2000:15:865-72
- Yang HS, Lang LA, Felton DA. Finite element stress analysis on the effect of splinting in fixed partial dentures. J Prosthet Dent 1999:81:721-8 https://doi.org/10.1016/S0022-3913(99)70113-7
- Ishigaki S, Nakano T, Yamada S, Nakamura T, Takashima F. Biomechanical stress in bone surrounding an implant under simulated chewing. Clin Oral Impl Res 2003:14:97-102
- Eskitascioglu G, Usumez A. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study. J Prosthet Dent 2004:91:144-50 https://doi.org/10.1016/j.prosdent.2003.10.018
- Ismail YH, Pahountis LN, Fleming JF. Comparison two-dimensional and three-dimensional finite element of a blade implant. J Oral Implantol 1987:4:25-31
- Timoshenko S, Young DH. Elements of strength of materials. 5th ed. Florence: Wadsworth : 1968. p.377-90
- Papavasiliou G, Kamposiora P, Bayne SC, Felton DA. Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prostheses type, and loading during function. J Prosthet Dent 1996:76:633-40 https://doi.org/10.1016/S0022-3913(96)90442-4
- Penny RE, Kraal JH. Crown-to-root ratio : Its significance in restorative dentistry. J Prosthet Dent 1979:42:34-38 https://doi.org/10.1016/0022-3913(79)90327-5
- Johnston JE, Phillips RW, Dykema RW. Modern Practice in crown and bridge prosthodontics, 3rd ed. 1971
- Reynolds JM. Abutment selection for fixed prosthodontics. J Prosthet Dent 1968:19:488-94
- Dykema RW. Fixed partial prosthodontics. J Tenn Dent Assoc 1962:43:309
- Leonard Krekmanov. Placement of posterior Mandibular and Maxillary implants in patients with severe bone deficiency: a clinical report of procedure. Int J Oral Maxillofac Implants 2000:15:722-730
- Glickman I, Stein S, Smulow JB. The effect of increased functional forces upon the periodontium of splinted and non-splinted teeth. J Periodontol 1961:32:290-9 https://doi.org/10.1902/jop.1961.32.4.290
- Glickman I, Roeber FW, Brion M, Pameijer JHN. Photoelastic analysis of internal stress in periodontium created by occlusal forces. J Periodontol 1970:41:41-3 https://doi.org/10.1902/jop.1970.41.41.41
- Wang TM, Leu LJ, Wang J, Lin LD. Effect of prosthesis materials and prosthesis splinting on peri-implant bone stress around in poor quality bone.: a numeric analysis. Int J Oral Maxillofac Implants 2002:17:231-7
- Duyck J, Naert I, Van OH, Ronold HJ, Vander SJ, Ellingsen JE. The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study. Clin Oral Implants Res 2001:12:207-18 https://doi.org/10.1034/j.1600-0501.2001.012003207.x
- Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994:9:345-60
- Ichikawa T, Kanitani H, Kawamato N, Matsumato N, Wigianto R. Influence of bone quality on the stress distribution. an in vitro experiment. Clin Oral Implants Res 1997:16:6-11
- Matsushita. Y. Two-dimensional FEM Analysis of Hydroxyapatite Implants: Diameter Effects on Stress Distribution. J Oral Implantol 1990:16:6-11
- Meijer HJ, Starmans FJ, Steen WH, Bosman F. Loading conditions of endosseous implants in an edentulous human mandible: a three-dimensional, finite-element study. J Oral Rehabil 1996:23:757-63 https://doi.org/10.1046/j.1365-2842.1996.d01-185.x
- Barbier L, Vander SJ, Krzesinski G, Schepers E, Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandibule of the dog. J Oral Rehabil 1998:25:847-858 https://doi.org/10.1046/j.1365-2842.1998.00318.x
- Choi MH, Kang JS, Boo SB, Oh SH, An OJ, Kang DW. Finite element stress analysis according to the point and surface occlusal loads on the implant prosthesis. J of Korean Academy Stomatognathic Function and Occlusion 2004:20:83-94
- Weinberg LA. Reduction of implant loading with therapeutic biomechanics. Implant Dent 1998:7:277-85 https://doi.org/10.1097/00008505-199807040-00005
- Zhang JK, Chen ZQ. The study of effects of the elastic modulus of the materials substitute to human hard tissues on the mechanical state in the implant-bone interface by three-dimensional anisotropic finite element analysis. West China J Stomatol 1998:16:274-278