References
- Tuovinen V, Norholt SE, Sindet-Pedersen S, Jensen J: A retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium miniplates. J Oral Maxillofac Surg 1994;52:931-93587 https://doi.org/10.1016/S0278-2391(10)80072-2
- Matthew IR, Frame JW: Policy of consultant oral and maxillofacial surgeons towards removal of miniplate components after jaw fracture fixation: pilot study. Br J Oral Maxillofac Surg 1999;37:110-112 https://doi.org/10.1054/bjom.1997.0084
- Iizuka T, Lindqvist C: Rigid internal fixation of mandibular fractures. An analysis of 270 fractures treated using the AO/ASIF method. Int J Oral Maxillofac Surg 1992;21:65-69 https://doi.org/10.1016/S0901-5027(05)80533-8
- Fiala TG, Novelline RA, Yaremchuk MJ: Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices. Plast Reconstr Surg 1993;92:1227-1232
- Fiala TG, Paige KT, Davis TL, Campbell TA, Rosen BR, Yaremchuk MJ: Comparison of artifact from craniomaxillofacial internal fixation devices: magnetic resonance imaging. Plast Reconstr Surg 1994;93:725-731 https://doi.org/10.1097/00006534-199404000-00011
- Schliephake H, Reiss G, Urban R, Neukam FW, Guckel S: Metal release from titanium fixtures during placement in the mandible: an experimental study. Int J Oral Maxillofac Implants 1993;8:502-511
- Jorgenson DS, Mayer MH, Ellenbogen RG, Centeno JA, Johnson FB, Mullick FG, Manson PN: Detection of titanium in human tissues after craniofacial surgery. Plast Reconstr Surg 1997;99:976-979 https://doi.org/10.1097/00006534-199704000-00006
- Eppley BL, Sadove AM, Havlik RJ: Resorbable plate fixation in pediatric craniofacial surgery. Plast Reconstr Surg 1997;100:1-7 https://doi.org/10.1097/00006534-199707000-00001
- Tharanon W, Sinn DP, Hobar PC, Sklar FH, Salomon J: Surgical outcomes using bioabsorbable plating systems in pediatric craniofacial surgery. J Craniofac Surg 1998;9:441-444 https://doi.org/10.1097/00001665-199809000-00008
- Ferretti C, Reyneke JP: Mandibular, sagittal split osteotomies fixed with biodegradable or titanium screws: a prospective, comparative study of postoperative stability. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2002; 93:534-537 https://doi.org/10.1067/moe.2002.124091
- Kim YK, Yeo HH, Lim SC: Tissue response to titanium plates: a transmitted electron microscopic study. J Oral Maxillofac Surg 1997;55:322-326 https://doi.org/10.1016/S0278-2391(97)90115-4
- Cutright DE, Hunsuck EE, Beasley JD: Fracture reduction using a biodegradable material, polylactic acid. J Oral Surg 1971;29:393-397
- Suuronen R: Biodegradable fracture-fixation devices in maxillofacial surgery. Int J Oral Maxillofac Surg 1993;22:50-57 https://doi.org/10.1016/S0901-5027(05)80358-3
- Suuronen R, Pohjonen T, Vasenius J, Vainionpaa S: Comparison of absorbable self-reinforced multilayer polyl- lactide and metallic plates for the fixation of mandibular body osteotomies: an experimental study in sheep. J Oral Maxillofac Surg 1992;50:255-262 https://doi.org/10.1016/0278-2391(92)90322-Q
- Kallela I, Laine P, Suuronen R, Iizuka T, Pirinen S, Lindqvist C: Skeletal stability following mandibular advancement and rigid fixation with polylactide biodegradable screws. Int J Oral Maxillofac Surg 1998;27:3-8 https://doi.org/10.1016/S0901-5027(98)80086-6
- Shand JM, Heggie AA: Use of a resorbable fixation system in orthognathic surgery. Br J Oral Maxillofac Surg 2000; 38:335-337 https://doi.org/10.1054/bjom.1999.0287
- Turvey TA, Bell RB, Tejera TJ, Proffit WR: The use of selfreinforced biodegradable bone plates and screws in orthognathic surgery. J Oral Maxillofac Surg 2002;60:59-65 https://doi.org/10.1053/joms.2002.28274
- Haers PE, Sailer HF: Biodegradable self-reinforced poly- L/DL-lactide plates and screws in bimaxillary orthognathic surgery: short term skeletal stability and material related failures. J Craniomaxillofac Surg 1998;26:363-372 https://doi.org/10.1016/S1010-5182(98)80069-3
- Schmidt BL, Perrott DH, Mahan D, Kearns G: The removal of plates and screws after Le Fort I osteotomy. J Oral Maxillofac Surg 1998;56:184-188 https://doi.org/10.1016/S0278-2391(98)90865-5