DOI QR코드

DOI QR Code

Design of FIR filter using direct memory access for voice signal processing module in implantable middle ear hearing devices

이식형 인공중이용 음성신호 처리 모듈을 위한 직접 메모리 억세스 기반의 FIR 필터 설계

  • Kim, Jong-Min (Dept. of Medical and Biological Engineering, Graduate School, Kyungpook National University) ;
  • Park, Il-Yong (Advanced Research Center for Recovery of Human Sensibility, Kyungpook National University) ;
  • Yoon, Young-Ho (School of Electrical Engineering and Computer Science, Kyungpook National University) ;
  • Kim, Min-Kyu (Dept. of Medical and Biological Engineering, Graduate School, Kyungpook National University) ;
  • Lim, Hyung-Gyu (School of Electrical Engineering and Computer Science, Kyungpook National University) ;
  • Han, Ji-Hun (School of Electrical Engineering and Computer Science, Kyungpook National University) ;
  • Kim, Myoung-Nam (Dept. of Biomedical Engineering, School of Medicine, Kyungpook National University) ;
  • Cho, Jin-Ho (School of Electrical Engineering and Computer Science, Kyungpook National University)
  • 김종민 (경북대학교 대학원 의용생체공학과) ;
  • 박일용 (경북대학교 첨단 감각기능 회복장치 연구센터) ;
  • 윤영호 (경북대학교 전자전기컴퓨터학부) ;
  • 김민규 (경북대학교 대학원 의용생체공학과) ;
  • 임형규 (경북대학교 전자전기컴퓨터학부) ;
  • 한지훈 (경북대학교 전자전기컴퓨터학부) ;
  • 김명남 (경북대학교 의과대학 의공학교실) ;
  • 조진호 (경북대학교 전자전기컴퓨터학부)
  • Published : 2006.07.30

Abstract

An FIR filter for digital voice signal processing has been designed and implemented using a microcontroller in implantable middle ear hearing devices (IMEHDs). The designed digital voice signal processing filter which has fast and accurate filtering operation and controllable filter characteristics has been implemented using a hardware multiplier and a direct memory access (DMA) in the low power microcontroller, MSP430F169. It has been confirmed that each of the implemented 6-orders Remez FIR filters with 1 channel and 2 channels can be applied to the voice signal processing module of IMEHDs based on the evaluation results of the filtering performance experiment.

Keywords

References

  1. R. L. Goode,M. L. Rosenbaum, and A. J. Maniglia, 'The history and development of the hearing aid', Otlolaryngologic Clinics ofNorth America, vol. 28, pp. 1-6, February, 1995
  2. A. Chasin, 'Current trends in implantable hearing aids', Trends in Amplification, vol. 2, no. 3, pp. 84107, June, 1997
  3. J. Suzuki, 'Middle ear implant: Implantable hearing aids', Karger Inc., Tokyo, 1988
  4. B. S. Song, 'Proposal and evaluation of vibration transducer with minimal magnetic field interference for use in IME system by in-vitro experiment', IEICE Transctions on Electronics, vol. E85-C, no. 6, pp. 1374-1377, June, 2002
  5. 조진호, 송병섭, 김명남, 원철호, 박세 광, 이상흔, '전 자 트랜스듀서 방식에 의한 청 각보조용 이식형 인 공중이 시스템 설계', 센서학회지 ,제 6권 ,제 6호, pp 466-475, 1997
  6. 임형규, 김종민 , 김 민규, 윤영호, 박일용, 송병섭 , 조진호, '완전 이식 형 인공중이를 위 한 베개형 비 접촉충전장치의 설계', 센서학회지, 제 14권 , 제 2호, pp. 78-84, 2005 https://doi.org/10.5369/JSST.2005.14.2.078
  7. Y.-C. Park, 'A digital hearing aid with 8-band curvilinear loudness fitting', ISCE'97-Proceedings of 1997 IEEE international Symposium on Consumer Electronics, pp. 39-42, December, 1997
  8. 이상민 , '시간 지연과 시변 상관성 제거 필 터를 이용한 디지털보청기 용 궤 환제 거 알고리 즘', 전자공학회 논문지 , 제42권 , SC 제 4호, pp. 45-50, 2005년 7월
  9. 강호경 , '완전 이식형 인공중이용 저전력 프로그래 머블 음성 신호 처리기', 석사학위논문, 경북대학교, 2004년 12월
  10. D. A. Chen, 'Phase I clinical trial results of the envoy system: A totally implantable middle ear device for sensorinural hearing loss', The American Academy of Otolaryngology Head and Neck Surgery Foundation Inc., pp. 904-916, 2004
  11. K. W. Berger, 'Prescriptive hearing aid selection strategies', Amplification fo r the Hearing-Impaired, Third Edition, pp. 273-293, Grune & Stratton Inc., 1988
  12. V. K. Ingle, 'MATLAB을 이용한 디지 털 신호 처리 ', 시그마프레스, 1998