Abstract

In the magnetic fluid linear pump, the pumping forces and pumping speed mainly depend on the current patterns. In this research, a new design to reduce the discontinuities of the pumping forces of the MFLP was studied. Continuous pumping of the newly designed MFLP by using AC current increases pumping efficiency and reduces the pumping force. Forming shapes of the magnetic fluid at the intermediate state were computed and compared to measurement. Since the back flow of the fluid is reduced remarkably, 4 yoke's AC driving is more efficient than 7 yoke's DC driving. The size, weight and pumping discontinuity are also reduced.

Keywords

References

  1. Yamaguchi M, et. al., 'Design investigation of linear motor for artificial heart driving', Trans. Institute of Elect. Eng. of Japan D-A Publication of Industry Applications Society, V.117-D, N. 5, 1997
  2. Parker RS, Doyle FJ, Peppas NA, 'A model-based algorithm for blood glucose control in type I diabetic patients', IEEE Trans. Mag., vol. 46, no. 2, pp 148-157, January 1999
  3. Matsuki H, et. al., 'Transcutaneous DC-DC converter for totally implantable artificial heart using synchronous rectifier', IEEE Trans. Mag., vol. 32, no. 5, pp 5118-5120, September 1996 https://doi.org/10.1109/20.539509
  4. Wen C, Li M, Whitworth JA, 'Validation of transonic small animal flowmeter for measurement of cardiac output and regional blood flow in the rat', J. Cardiovascular Pharmacology, vol. 27, no. 4, April 1996
  5. Verotta D, 'A general solution for nonparametric control of a linear system using computer-controlled infusion pumps', IEEE Trans. Mag., vol. 46, no. 1, pp 44-50, January 1999
  6. Daoura MJ, Meldrum DR, 'Precise automated control of fluid volumes inside glass capillaries', J. Microelectro-mechanical Systems, vol. 8, no. 1, pp 71 -77, March 1999 https://doi.org/10.1109/84.749405
  7. Melcher, James R., 'Continuum Electromechanics', 1981
  8. Gwan Soo Park and Sang Ho Park, 'Design of Magnetic Fluid Linear Pump', International Magnetics Confereance, Kyongju, Korea, May 18-21 1999
  9. Gwan Soo Park and Sang Ho Park, 'Design of Magnetic Fluid Linear Pump', IEEE Trans. Magn., Vol.35, No.5, pp. 4058-4060, September 1999 https://doi.org/10.1109/20.800754
  10. Gwan Soo Park and Sang Ho Park, ' New Structure of the Magnetic Fluid Linear Pump', IEEE Intermag2000, 2000 IEEE International Magnetics Conference, pp. GS-02, Toronto, Canada, April 9-13, 2000
  11. Gwan Soo Park and Sang Ho Park, ' New Structure of the Magnetic Fluid Linear Pump', IEEE Trans. Magn., Vol.36, No.5, pp. 3709-3711, September 2000 https://doi.org/10.1109/20.908948
  12. G.S. Park, S.H. Park, 'Determination of the Curvature of the Magnetic Fluid under the External Forces', The 13th COMPUMAG Conference on the Computation of Electromagnetic Fields, Evain, France, July 2-5, 2001
  13. G.S. Park, S.H. Park, 'Determination of the Curvature of the Magnetic Fluid under the External Forces', IEEE Trans. Magn., Vol.38, No.2, pp. 957-960, March 2002 https://doi.org/10.1109/20.996246
  14. Gwan Soo Park, Kang Seo, 'A Study on the Pumping Forces of the Magnetic Fluid Linear Pump', CEFC 2002, Proceedings of the Tenth Biennial IEEE Conference on Electromagnetic Field Compotation, pp 104, Perugia, Italy, June 16-19 2002
  15. Gwan Soo Park, Kang Seo, 'A Study on the Pumping Forces of the Magnetic Fluid Linear Pump', IEEE Trans. Magn., vol 39, no, 3, pp. 1468-1471, May 2003 https://doi.org/10.1109/TMAG.2003.810218
  16. 서강, 박관수, 'Permalloy Yoke를 이용한 Magnetic Fluid Linear Pump의 소형화 설계', 대한전기학회 2001년도 하계 학술 대회 논문집, pp. 789-791, 2001년 7월 18일 - 20일, 용평
  17. 서강, 박관수, '동작 전류에 의한 Magnetic Fluid Linear Pump의 동특성 해석', 대한전기학회지, 제 53B권 4호, pp. 237-246, 2004년 4월