DOI QR코드

DOI QR Code

Modeling and Analysis of Variable Wind Speed Turbine System Using Back to Back Converter

Back to bock 컨버터를 갖는 가변속 풍력터빈 시스템의 모델링과 해석

  • 김일환 (제주대학교 전기전자공학부) ;
  • 강경보 (제주대학교 전기전자공학부) ;
  • 김재홍 (제주대학교 전기전자공학부) ;
  • 문상호 (제주대학교 전기전자공학부) ;
  • 오성보 (제주대학교 전기전자공학부) ;
  • 김세호 (제주대학교 전기전자공학부)
  • Published : 2005.12.31

Abstract

This paper presents the simulation modeling and analysis of variable wind speed turbine system(VWTS) using the doubly fed induction generator(DFIG) connected the back to back converter system in the rotor side. In the simulation, using the model system which has the 660[kW] rated power, blade control and the dual converter system are modeled for verifying the control characteristics. The VWTS is controlled by the optimal pitch angle for maximum output power under the rated wind speed, and for the rated output power over the rated wind speed. And also power factor is controlled by the reactive power. To verify the effectiveness of the proposed method, simulation results are compared with the actual data from the V47 VWTS located in Hangwon wind farm in Jeju-Do. According to the comparison of these results, this method shows excellent performance.

본 논문에서는 이중여자 유도발전기의 회전자에 back to back 컨버터가 채용된 가변속 풍력터빈 시스템의 모델링과 해석을 나타내었다. 제어시스템의 특성을 파악하기 위해서 시뮬레이션에서는 Psim 프로그램을 사용하여 660[kW] 의 출력정격을 갖는 시스템을 모델로 하였다. 모델링에서는 블레이드 제어 시스템 모델과 회전자와 계통선에 연결된 컨버터 시스템을 모델링 하였다. 풍속의 변화에 따라 원하는 출력을 얻을 수 있도록 피치각을 제어하여 정격풍속 이하에서도 최대출력이 발생하도록 하였고, 정격풍속 이상에서는 회전자 속도를 일정하게 하여 정격출력을 유지할 수 있도록 하였다. 또한 무효전력을 제어하여 출력의 역률을 제어하였다. 제안한 해석방법의 타당성을 검증하기 위하여 풍속변화에 따른 모델 시스템의 시뮬레이션 결과 값들과 제주행원 풍력발전 단지에서 운용되고 있는 V47 660[kW] 시스템의 실측 결과들과 서로 비교 검증하여 제안한 해석 방법의 타당성을 입증하였다.

Keywords

References

  1. Arantxa Tapia, Gerardo Tapia, J.Xabier Ostolaza, and Jose Ramon Saemz, 'Modeling and Control of a Wind Turbine Driven Double Fed Induction Generator', IEEE Transactions on energy conversion, vol.18, pp. 194-204, 2003 https://doi.org/10.1109/TEC.2003.811727
  2. BY S. Muller, M. Deicke, and RIK W. De Doncker, 'Doubly Inductiona Generator System for Wind turbines' IEEE Industry Applications Magazine, vol. , pp. 26-33, 2002
  3. Ezzeldin S. Abdin, and Wilson Xu, 'Control Design and Dynamic Performance Analysis of a Win Turbine Induction Generator Unit', IEEE Transactions on Energy Conversion, vol.15, pp. 99-96, 2000
  4. H. Camblong , M. Rodriguez Vidal, and J. R. Puiggali, 'Principles of a Simulation Model for a Variable-speed Pitch-regulated Wind Turbine', Wind Engineering, Vol. 28, pp. 157-175, 2004 https://doi.org/10.1260/0309524041211369
  5. L. Xu, Li Zhen and E. H. Kim, 'Field Orientation Control of a Doubly Excited Brushless Reluctance Machine', IEEE Trans. Appl. Vol. 34. No. 1, Jan/Feb.,1998 https://doi.org/10.1109/28.658739
  6. H. Camblong, M. Rodringuez Vidal, J. R. Puiggali, 'Principles of a Simulation Model for a Variable Speed Pitch-regulated Wind Turbine', Wind Eng., vol. 28, No. 2, pp.157-175., 2004 https://doi.org/10.1260/0309524041211369

Cited by

  1. A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System vol.27, pp.11, 2013, https://doi.org/10.5207/JIEIE.2013.27.11.027
  2. A Study on the Integrated Simulation and Condition Monitoring Scheme for a PMSG-Based Variable Speed Grid-Connected Wind Turbine System under Fault Conditions vol.27, pp.3, 2013, https://doi.org/10.5207/JIEIE.2013.27.3.065