A hybrid discharge type ozonizer, which is superposed silent and surface discharges, has been designed and manufactured to apply for Nitrogen Oxides(NO) gas removal. The ozonizer consists of three electrodes, and is classified three types of ozonizer by changing applied voltage. Investigation was carried out variance with the flow rate of supplied oxygen gas, discharge power and the sorts of superposed discharge type ozonizer. Moreover, NO(1200[ppm])/$N_2$ gas removal investigation was also conducted to apply for environment improvement field. Two kinds of NO gas removal investigations were conducted. It distinguishes the investigations into NO gas reaction method. According to these studies, maximum removal rate of 100[%] in NO gas was obtained, and 8334[ppm] and 3249[mg/h] of maximum ozone concentration and generation were also obtained respectively.

본 논문에서는 대기오염물질인 Nitrogen Oxides(NO) 가스를 제거하기 위하여 3개의 전극이 장착된 하나의 방전 공간에 무성방전과 연면방전을 동시에 발생가능한 복합방전형 오존발생기를 설계 제작하였다. 전압인가 방식에 따라 3가지 형태의 오존발생기로 구성가능한 복합방전형 오존발생기에 유입하는 산소원료가스의 유량, 방전전력 및 오존발생기의 종류에 따른 방전 및 오존생성특성을 연구 검토한 결과, 8334[ppm] 및 3249[mg/h]의 오존을 얻을 수 있었다. 또한 NO(1200[ppm])/$N_2$ 가스의 입력방식에 따른 NO 가스 제거특성을 방전전력 및 오존발생기의 종류에 따라 연구 검토한 결과, 최대 100[%]의 제거율을 얻을 수 있었다.

Keywords

References

  1. M.Higashi et al, 'Soot elimination and NOx and SOx reduction in diesel engine exhaust by a combination of discharge plasma and oil dynamics', IEEE Trans. on Plasma Science, Vol.20, pp.1-12, 1992 https://doi.org/10.1109/27.120185
  2. W.J.M.Samaranayake et al, 'Pulsed power production of ozone in $O_2/N_2$ in acoaxial reactor without dielectric layer', IEEE Trans. on Dielectric and Electrical Insulation, Vol.8, No.5, pp.826-831, 2001 https://doi.org/10.1109/94.959711
  3. K.S.Lee, H.J.Song et al, 'Fundamental Engineering of Energy', Bookshill Publishing Company, 2004
  4. Tetsuji Oda et al, 'Nitric oxide decomposition in air by using nonthermal plasma processing with additives and catalyst', IEEE Trans. on Industry Applications, Vol.34, No.2, pp.268-272, 1998 https://doi.org/10.1109/28.663466
  5. Remy Bendahan et al, 'Nitrogen oxides decomposition using a dielectric barrier discharge reactor', T. IEE, Vol.118-A, No.4, pp.380-386, 1998
  6. Yukimura.K., 'Correction of energy of NO removal by intermittent DBD radical injection method', IEEE Trans. on Plasma Science, Vol.33, Issue 2, pp.763-770, 2005 https://doi.org/10.1109/TPS.2005.844610
  7. Fujiwara.K. et al, 'The effect of carbonaceous deposit for NOx dissociation by barrier discharge', ICOPS, pp.20-24, 1999 https://doi.org/10.1109/PLASMA.1999.829521
  8. Keping Yan et al, 'NOx removal from air streams by a superimposed AC/DC energized flow stabilized streamer corona', T. IEE, Vol.118-A, No.9, pp.948-953, 1998
  9. Kuniko Urashima et al, 'Reduction of NOx from natural gas combustion flue gases by corona discharge radical injection techniques', IEEE Trans. on Industry Applications, Vol.34, No.5, pp.934-939, 1998 https://doi.org/10.1109/28.720432
  10. Keping Yan et al, 'Streamer-glow-spark transition in a corona radical shower system during NOx removal operation', T. IEE, Vol.119-A, No.7, pp.938-943, 1999
  11. E. M. van Veldhuizen, et.al. 'Energy Efficiency of NO Removal by Pulsed Corona Discharges', Plasma Chemistry and Plasma Processing, Vol 16, No. 2, pp. 227-247, 1996 https://doi.org/10.1007/BF01570180
  12. S. Kanazawa, J. S. Chang, G. F. Round, G. Sheng, T. Nomoto and T. Adachi, 'Removal of NOX from Flue Gas by Corona Discharge Activated Methane Radical Showers', Journal of Electrostatics 40&41, pp. 651-656, 1997 https://doi.org/10.1016/S0304-3886(97)00072-7