다양한 가상 골 결함에 따른 공진 주파수의 비교 분석

A COMPARATIVE ANALYSIS WITH RESONANCE FREQUENCY ACCORDING TO VARIOUS SIMULATED BONE DEFECTS

  • 김상미 (강릉대학교 치과대학 치과보철학교실 및 구강과학연구소) ;
  • 박찬진 (강릉대학교 치과대학 치과보철학교실 및 구강과학연구소) ;
  • 이양진 (강릉대학교 치과대학 치과보철학교실 및 구강과학연구소) ;
  • 장범석 (강릉대학교 치과대학 치주과학교실 및 구강과학연구소) ;
  • 조리라 (강릉대학교 치과대학 치과보철학교실 및 구강과학연구소)
  • Kim Sang-Mi (Department of Prosthodontics, Research Institute of Oral Science, College of Dentistry, Kangnung National University) ;
  • Park Chan-Jin (Department of Prosthodontics, Research Institute of Oral Science, College of Dentistry, Kangnung National University) ;
  • Yi Yang-Jin (Department of Prosthodontics, Research Institute of Oral Science, College of Dentistry, Kangnung National University) ;
  • Chang Beom-Seok (Department of Periodontology, Research Institute of Oral Science, College of Dentistry, Kangnung National University) ;
  • Cho Lee-Ra (Department of Prosthodontics, Research Institute of Oral Science, College of Dentistry, Kangnung National University)
  • 발행 : 2005.08.01

초록

Purpose: Resonance frequency analysis (RFA) , a non-invasive technique for the clinical measurement of implant stability, was investigated. Peri-implant bony defect may contribute to implant failure. This in vitro study evaluated the resonance frequencies according to various bony defects and determined whether the directional bone defect can affect the value of frequency analysis. Material and Method: Fifteen 3.75 mm in diameter and 10 mm in length, machined self-tapping implant future were used. Twelve types of bone defects that have different horizontal and vertical dimensions were simulated. Embedded implants were attached to the dental surveyor. Then, the transducer was connected with the implant fixture and the ISQ value was measured at four different directions. Two-way analysis of variance and post hoc $Sch\`{e}ffe'$ test were performed at the 95% significance level. Results: The control group showed the highest ISQ value and 5 thread-$360^{\circ}$ group had the lowest one. As the vertical exposure of implants in each angle was increased, the ISQ value was decreased. Although the horizontal exposure in each thread was increased, the ISQ value was not significantly decreased. Conclusion : Although the simulated defect type was different from each other, the ISQ value was similar among groups.

키워드

참고문헌

  1. Zarb GA, Schmitt A. Osseointegration and the edentulous predicament. The 10-year-old Toronto study. Br Dent J 1991; 170:439-444 https://doi.org/10.1038/sj.bdj.4807583
  2. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1988: 11 :491-501
  3. Sennerby L, Meredith N. Resonance frequency analysis: Measuring implant stability and osseointegration. Compendium 1998: 19:493-502
  4. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res 1996: 7: 261-267 https://doi.org/10.1034/j.1600-0501.1996.070308.x
  5. Meredith N. Determination of the elastic modulus of resin based materials as a function of resonance frequency during polymerisation. Dent mate 1999:15:98-104 https://doi.org/10.1016/S0109-5641(99)00019-6
  6. Meredith N. Shagaldi F, Sennerby L. Alleyne D, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Impl Res 1997;8:234-243 https://doi.org/10.1034/j.1600-0501.1997.080310.x
  7. Meredith N, Friberg B, Jemt T. Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Impl Res 1997; 8: 226-233 https://doi.org/10.1034/j.1600-0501.1997.080309.x
  8. Park C, Lim JH, Cho IH. Lim HS. A study of the measurement of the implant stability using resonance frequency analysis. J Korean Academy of Prosthodontics 2003 :41: 182-206
  9. Meredith N. Rasmussen L, Sennerby L, Alleyne D. mapping implant stability by resonance frequency analysis. Med Sci Res 1996:24: 191-193
  10. Park CJ. In vitro comparative study between ISQ and Periotest values on the implant stability measurements according to the increased effective implant length. J Korean Academy of Prosthodontics 2001: 39:625-635
  11. Lekholm U, Adell R, Branemark P-I. Complications. In: Branemark P-I, Zarb GA, Albreksson T(eds). Tissue-integrated prostheses: Osseointegration in clinical Dentistry. Chicago: Quintessence. 1985:233-240
  12. Jaffin RA, Berman Cl. The excessive loss of Branemark fixture in type IV bone: a 5-year analysis. J Periodontol 1991:62:2-4 https://doi.org/10.1902/jop.1991.62.1.2
  13. Friberg B. Jemt T. Lekholm U: Early failures in 4,641 consecutively placed Brenemark dental implants. A study from stage I surgery to the connection of completed prostheses. Int J Oral Maxillofac Impl 1991 :6: 142-146
  14. Fugazzotto PA, Wheeler SL, Lindsay JA. Success and failure rates of cylinder implants in type IV bone. J Periodontol 1993: 64:1085-1087 https://doi.org/10.1902/jop.1993.64.11.1085
  15. Lundgren D, Sennerby L, Falk H, Friberg B, Nyman S. The use of a new bioresorbable barrier for guided bone regeneration in connection with implant installation. Case reports. Clin Oral Implants Res 1994:5:177-184 https://doi.org/10.1034/j.1600-0501.1994.050309.x
  16. Dahlin C, Lekholm U, Linde A. Membraneinduced bone augmentation at titanium implants. A report on ten fixtures followed from 1 to 3 years after loading. Int J Periodontics Restorative Dent 1991: 11 :273-281
  17. Tinti C. Parma-Benfenati S. Clinical classification of bone defects concerning the placement of dental implants. Int J Periodontics restorative Dent 2003:23:147-155
  18. Yun KS. Kwon JS. Kim DK. SuI YT. Assessment of implant stability in an osseointegration simulated model. Quintessence Dental Implantology 2002:4: 360-363
  19. Van Oosterwyck H, Duyck J, Vander Sloten J, Van Der Perre G, Naert I. Periimplant bone tissue strains in cases of dehiscence: a finite element study, Clin Oral Implants Res 2002:13:327-333 https://doi.org/10.1034/j.1600-0501.2002.130314.x
  20. Mojon P, Oberholzer JP, Meyer JM, Belser UC. Polymerization shrinkage of index and pattern acrylic resins. J Prosthet Dent 1990:64:684-688 https://doi.org/10.1016/0022-3913(90)90296-O