하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석

PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION

  • 조혜원 (원광대학교 치과대학 보철학교실) ;
  • 김난영 (원광대학교 치과대학 보철학교실) ;
  • 김유리 (원광대학교 치과대학 보철학교실)
  • Cho Hye-Won (Dept. of Prosthodontics, College of Dentistry, Wonkwang University) ;
  • Kim Nan-Young (Dept. of Prosthodontics, College of Dentistry, Wonkwang University) ;
  • Kim Yu-Lee (Dept. of Prosthodontics, College of Dentistry, Wonkwang University)
  • 발행 : 2005.02.01

초록

Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

키워드

참고문헌

  1. Lekholm U, van Steenberghe D, Herrmann I. Bolender C, Folmer T, Gunne J et al. Osseointegrated implants in the treatment of partially edentulous jaws. A prospective 5-year multicenter study. Int J Oral Maxillofac Implants 1994;9:627-635
  2. Rangert B, Krogh P, Langer B, and Roekel N. Bending overload and implant fracture: A retrospective clinical analysis Int J Oral Maxillofac Implants 1995;10:326-334
  3. Rangert BR, Sullivan RM, Jemt TM. Load factor control for implants in the posterior partially edentulous segment. Int J Oral Maxillofac Implants 1997;12:360-370
  4. Taylor TD, Agar JR, Vogiatzi T. Implant prosthodontics: Current perspective and future directions. Int J Oral Maxillofac Implants 2000;15:66-75
  5. Kunavisarut C, Lang LA, Stoner BR, Felton DA. Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont 2002;11:30-40
  6. Serio FG. Clinical rationale for tooth stabilization and splinting. Dent Clin North Am 1999;43:1-6
  7. Stegaroiu R, Sato T, KusaKari H, Miyakawa O. Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis Int J Oral Maxillofac Implants 1998;13:82-90
  8. Landry KE, Jonhson PF, Parks VJ, Pelleu GB Jr. A photoelastic study to determine the location of the nonrigid connector in a five-unit intermediate abutment prosthesis J Prosthet Dent 1987;57:454-457 https://doi.org/10.1016/0022-3913(87)90014-X
  9. Hoshaw SJ, Brunski JB, Cochran GV. Mechanical loading of Branemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994;9:345-360
  10. Fleming AE. The Endopore dental implant system: Implant treatment simplified. J Can Dent Res 1994;60:785-789
  11. Fischman B. The rotational aspect of mandibular flexure. J Prosthet Dent 1990;64:483-485 https://doi.org/10.1016/0022-3913(90)90049-I
  12. Weinberg LA, Kruger B. An evaluation of torque (moment) on implant/prosthesis with staggered buccal and lingual offset. Int J Periodontics Restorative Dent 1996;16: 252-265
  13. Celleti R, Pameijer CH, Bracchetti G, Konath K, Persichetti G, Visani I. Histologic evaluation of osseointegrated implants restored in nonaxial functional occlusion with preangled abutments. Int J Periodontics Restorative Dent 1995;15:563-573
  14. Akca K, lplikcioglu H. Finite element stress analysis of the influencde of staggered versus straight placement of dental implants.-5 Int J Oral Maxillofac Implants 2001;16:722-730
  15. Itoh H, Caputo AA, Kuroe T, Nakahara H. Biomechanical comparison of straight and staggered implant placement configurations. Int J Periodontics Restorative Dent 2004;24:47-55