A Study on Effect of Shotcrete Adhesive Strength on Large Section Rock Tunnel Stability

대단면 암반터널의 안정성에 미치는 숏크리트 부착강도의 영향에 관한 연구

  • 장석부 ((주)유신코퍼레이션 터널부) ;
  • 홍의준 ((주)유신코퍼레이션 터널부) ;
  • 문상조 ((주)유신코퍼레이션 지반본부)
  • Published : 2005.12.30

Abstract

Shotcrete adhesive strength in large section tunnels in jointed rock masses plays an important role in preventing rock block from falling and shotcrete debonding due to blasting vibration. Nevertheless, it has not been considered as a major factor such as shotcrete compressive strength in design and construction. For this reason, the purpose of this study is to analyze the effect on shotcrete adhesive strength for large-sectioned tunnels. First, the parametric study using numerical model similar to Holmgren's punch-loaded test was executed for various range of adhesive strength. It shows that the shotcrete bearing capacity is linearly proportioned to the adhesive strength between shotcrete layer and blocks. And then, distinct element analysis of a jointed rock tunnel for an adhesive strength of 1 MPa and a conventional fully-bonded condition between the shotcrete layer and the excavation face was compared in order to evaluate the effect of the shotcrete adhesive strength.

암반에 건설되는 대단면 터널에서 숏크리트의 부착강도는 암반탈락 방지와 발파진동에 의한 숏크리트 탈락방지에 매우 중요하다. 그럼에도 불구하고 숏크리트 부착강도는 압축강도에 비하여 설계 및 시공단계에서 중요한 요소로 고려되지 않았다. 따라서 본 연구의 목적은 숏크리트 부착강도가 대단면 암반 터널의 안정성에 미치는 영향을 분석하는 것이다. 먼저, Holmgren의 punch-loaded 시험조건을 모사한 수치해석 모델을 이용하여 다양한 부착강도에 대한 매개변수연구를 수행하였다. 그 결과, 숏크리트의 최대지지력은 숏크리트층과 블록간의 부착 강도와 선형 비례관계를 보임을 확인하였다. 또한, 숏크리트층과 굴착면에 부착강도를 고려하는 경우와 기존의 완전부착 조건에 대한 개별요소해석을 수행하여 숏크리트 부착강도의 영향을 검토하였다.

Keywords

Acknowledgement

Supported by : 한국건설교통기술평가원