Micromorphometric change of implant surface conditioned with tetracycline-HCI;HA and oxidized surface

표면처리 시간에 따른 임플란트 미세구조의 변화;HA와 양극산화 표면 임플란트

  • 안상호 (경희대학교 치과대학 치주과학교실) ;
  • 박준봉 (경희대학교 치과대학 치주과학교실) ;
  • 권영혁 (경희대학교 치과대학 치주과학교실) ;
  • 허익 (경희대학교 치과대학 치주과학교실) ;
  • 정종혁 (경희대학교 치과대학 치주과학교실)
  • Published : 2005.12.31

Abstract

The present study was performed to evaluate the effect of tetracycline-HCL on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface. HA-coated surface and TiUniteTM surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline-HCL solution for $\frac{1}{2}min.$, 1min., $1\frac{1}{2}min.$, 2min., and $2\frac{1}{2}min.$ respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The anodic oxidized surfaces showed the craterous structures. The surface conditioning with tetracycline-HCl didn't influence on its micro-morphology. In conclusion, the detoxification with 50mg/ml tetracycline-HCL must be applied respectively with different time according to various implant surfaces.

Keywords

References

  1. Branemark PI, Hansson BO. Adell R. Breine U. Lindstrom J. Hallen O. Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977: 16(Suppl. 1): 1-132
  2. Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986: 1: 11-25
  3. Meffert RM, Langer B, Fritz ME. Dental implants: A review. J Periodontol 1992: 63:859-70 https://doi.org/10.1902/jop.1992.63.11.859
  4. Quirynen M, Naert I, Van Steenberghe D. Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clin Oral Implants Res 1992:3:104-111 https://doi.org/10.1034/j.1600-0501.1992.030302.x
  5. Isidor F. Loss of osseointegration caused by occlusal load of oral implants. Clin Oral Implants Res 1996:7:143-152 https://doi.org/10.1034/j.1600-0501.1996.070208.x
  6. Mombelli A, Van Oosten MAC, Schürch EJ, Lang NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 1987:2: 145-151 https://doi.org/10.1111/j.1399-302X.1987.tb00298.x
  7. Hickey JS, O'Neal RB, Scheidt MJ, Strong SL, Yurgeon D, Van Dyke TE. Microbiologic characterization of ligature induced peri-implantitis in the microswine model. J Periodontol 1991:62: 548-553 https://doi.org/10.1902/jop.1991.62.9.548
  8. Mombelli A, Lang NP. The diagnosis and treatment of peri-implantitis. Periodontol 2000 1998: 17:63-76 https://doi.org/10.1111/j.1600-0757.1998.tb00124.x
  9. Roos-Jansaker AM, Renvert S, Egelberg J. Treatment of peri-implant infections: a literature review. J Clin Periodontol 2003; 6: 467-85
  10. Esposito M. Hirsch J, Lekholm U, Thomsen P. Differential diagnosis and treatment strategies for biologic complications and failing oral implants: a review of the literature. Int J Oral Maxillofac Implants 1999;4:473-90
  11. Baron M. Haas R, Dortbudak O, Watzek G. Experimentally induced peri-implantitis: a review of different treatment methods described in the literature. Int J Oral Maxillofac Implants 2000:4:533-44
  12. Krozer A, Hall J, Ericsson I. Chemical treatment of machined titanium surfaces. An in vitro study. Clin Oral Implants Res 1999;3:204-11
  13. Thomson-Neal D, Evans GH. Meffert RM. Effects of various prophylactic treatments on titanium. sapphire. and hydroxyapatite-coated implants: an SEM study. Int J Periodontics Restorative Dent 1989:4:300-11
  14. Zablotsky MH. Diedrich DL, Meffert RM. Detoxification of endotoxin contaminated titanium and hydroxyapatitecoated surfaces utilizing various chemotherapeutic and mechanical modalities. Implant Dent 1992;2: 154-8
  15. Dennison DK, Huerzeler MB, Quinones C. Caffesse RG. Contaminated implant surfaces: an in vitro comparison of implant surface coating and treatment modalities for decontamination. J Periodontol 1994; 10:942-8
  16. Dörtbudak O, Haas R, Bernhart T, Mailath-Pokorny G. Lethal photo-sensitization for decontamination of implant surfaces in the treatment of peri-implantitis. Clin Oral Implants Res 2001:2: 104-8
  17. Somerman MJ, Foster RA, Vorsteg GM, Progebin K. Wynn RL. Effects of minocycline on fibroblast attachment and spreading. J Periodontal Res 1988:2: 154-9
  18. Meffert RM. How to treat ailing and failing implants. Implant Dent 1992: 1: 25-33 https://doi.org/10.1097/00008505-199200110-00003
  19. Bell FA, Cavazos EJ, Jones AA, Stewart KL. Four-year experience with the placement, restoration, and maintenance of dental implants by dental students. Int J Oral Maxillofac Implants 1994:9: 725-731
  20. Artzi Z, Tal H, Chweidan H. Bone regeneration for reintegration in peri-implant destruction. Compend Contin Educ Dent 1998; 1: 17-28
  21. Jovanovic SA, Kenney EB, Carranza EA, Donath K. The regenerative potential of plaque induced peri-implant bone defects treated by a submerged membrane technique: an experimental study. Int J Oral Maxillofac Implants 1993; 8:13-18
  22. Hurzeler MB, Quinones CR, Morrison EC, Caffesse RG. Treatment of peri-implantitis using guided bone regeneration and bone grafts, alone or in combination, in beagle dogs. Part 1: Clinical findings and histologic observations. Int J Oral Maxillofac Implants 1995:4: 474-84
  23. Hürzeler MB, Quinones CR, Schüpbach P, Morrison EC, Caffesse RG. Treatment of peri-implantitis using guided bone regeneration and bone grafts, alone or in combination, in beagle dogs. part II: Histologic finding. Int J Oral Maxillofac Implants 1997; 12: 168-175
  24. Persson LG, Ericsson I. Berglundh T, Lindhe J. Guided bone regeneration in the treatment of periimplantitis and replacement of implant components. An experimental study in the dog. J Clin Periodontol 2001; 28: 258-263 https://doi.org/10.1034/j.1600-051x.2001.028003258.x
  25. Persson LG, Berglundh T, Lindhe J, Sennerby L. Re-osseointegration after treatment of peri-implantitis at different implant surfaces. An experimental study in the dog. Clin Oral Implants Res 2001 ; 6: 595-603
  26. Albrektsson TO, Johansson CB, Sennerby L. Biological aspects of implant dentistry: Osseointegration. Periodontol 2000 1994:4:58-73 https://doi.org/10.1111/j.1600-0757.1994.tb00006.x
  27. Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 1991:7:889-902
  28. Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acidetched surface: a histometric study in the canine mandible. J Biomed Mater Res 1998: 1 : 1-11 https://doi.org/10.1002/jbm.820010102
  29. Rimondini L, Fare S, Brambilla E, Felloni A, Consonni C, Brossa F, Carrassi A. The effect of surface roughness on early in vivo plaque colonization on titanium. J Periodontol 1997:6:556-62
  30. Lindhe J. Karring T, Lang NP. Surface topography of titanium implants. Clinical periodontology and implant dentistry 2003:4th edition: 821-828
  31. Ong JL, Carnes DL, Bessho K. Evaluation of titanium plasma-sprayed and plasma-sprayed hydroxyapatite implants in vivo. Biomaterials 2004; 19:4601-6
  32. Ivanoff CJ, Widmark G, Johansson C, Wennerberg A. Histologic evaluation of bone response to oxidized and turned titanium micro implants in human jawbone. Int J Oral Maxillofac Implants 2003; 3: 341-8
  33. Johnson BW. HA-coated dental implants : Long-term consequences. J Calif Dent Assoc 1992: 6: 33-41
  34. Schou S, Holmstrup P, Jorgensen T. Skovgaard LT, Stoltze K. Hjorting-Hansen E, Wenzel A. Anorganic porous bovine-derived bone mineral(Bio-Oss) & ePTFE membrane in the treatment of peri-implantitis in cynomolgus monkeys. Clin Oral Implants Res 2003:5:535-47
  35. Chairay JP, Boulekbache H. Jean A, Soyer A, Bouchard P. Scanning electron microscopic evaluation of the effects of an air-abrasive system on dental implants: A comparative in vitro study between machined and plasma-sprayed titanium surfaces. J Periodontol 1997; 68: 1215-1222 https://doi.org/10.1902/jop.1997.68.12.1215
  36. Augthun M, Tinschert J, Huber A. In vitro studies on the effect of cleaning methods on different implant surfaces. J Periodontol 1998:69:857-64 https://doi.org/10.1902/jop.1998.69.8.857
  37. Rimondini L, Cicognani Simoncini F, Carrassi A. Micro-morphometric assessment of titanium plasma-sprayed coating removal using burs for the treatment of peri-implant disease. Clin Oral Implants Res 2000:2: 129-38
  38. Baker P, Evans R. Coburn R. Genco R. Tetracycline and its derivatives strongly bind to and are released from tooth surface in active form. J Periodontol 1983:54(10):580-585 https://doi.org/10.1902/jop.1983.54.10.580
  39. Glaub LM, Lee HM, Lehrer G, Nemiroff A, McNamara TF, Kaplan R, Ramamurthy NS. Minocycline reduces gingival collagenolytic activity during diabetes. J Periodontal Res 1983: 18:516-526 https://doi.org/10.1111/j.1600-0765.1983.tb00388.x
  40. Al-Ali W, Bissada NF, Greenwell H. The effect of local doxycycline with and without tricalcium phosphate on the regenerative healing potential of periodontal osseous defects in dogs. J Periodontol 1989:60:582-590 https://doi.org/10.1902/jop.1989.60.10.582
  41. Pepelassi EM, Bissada NF, Greenwell H. Farah CF. Doxycycline-tricalcium phosphate composite graft facilitates osseous healing in advanced periodontal furcation defects. J Periodontol 1991: 62: 106-115 https://doi.org/10.1902/jop.1991.62.2.106
  42. Wittrig EE. Zablotsky MH, Layman R.M., Fibroblastic growth and attachment on hydroxyapatite-coated titanium surfaces following the use of various detoxification modalities. Implant Dent 1992; 1: 189-194 https://doi.org/10.1097/00008505-199200130-00005
  43. Mellonig JT, Griffiths G, Mathys E. Spitznagel J Jr. Treatment of the failing implant: case reports. Int J Periodontics Restorative Dent 1995:4:384-95
  44. Muller E, Gonzalez YM, Andreana S. Treatment of peri-implantitis: Longitudinal clinical and microbiological findings- a case report. Implant Dentistry 1999; 3: 247-254
  45. Mouhyi J, Sennerby L, Pireaux JJ, Dourov N, Nammour S, Van Reck J. An XPS and EM evaluation of six chemical and physical techniques for cleaning of contaminated titanium implants. Clin Oral Implants Res 1998;3: 185-94
  46. 김우영, 박준봉, 이만섭, 허익. 염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구. 대한치주과학회지 2002;3:523-532