DOI QR코드

DOI QR Code

Shielding effects and buckling of steel tanks in tandem arrays under wind pressures

  • Portela, Genock (General Engineering Department, University of Puerto Rico) ;
  • Godoy, Luis A. (Civil Infrastructure Research Center, Department of Civil Engineering and Surveying, University of Puerto Rico)
  • Received : 2004.09.14
  • Accepted : 2005.04.20
  • Published : 2005.10.25

Abstract

This paper deals with the buckling behavior of thin-walled aboveground tanks under wind load. In order to do that, the wind pressures are obtained by means of wind-tunnel experiments, while the structural non linear response is computed by means of a finite element discretization of the tank. Wind-tunnel models were constructed and tested to evaluate group effects in tandem configurations, i.e. one or two tanks shielding an instrumented tank. Pressures on the roof and on the cylindrical part were measured by pressure taps. The geometry of the target tank is similar in relative dimensions to typical tanks found in oil storage facilities, and several group configurations were tested with blocking tanks of different sizes and different separation between the target tank and those blocking it. The experimental results show changes in the pressure distributions around the circumference of the tank for half diameter spacing, with respect to an isolated tank with similar dimensions. Moreover, when the front tank of the tandem array has a height smaller than the target tank, increments in the windward pressures were measured. From the computational analysis, it seems that the additional stiffness provided by the roof prevents reductions in the buckling load for cases even when increments in pressures develop in the top region of the cylinder.

Keywords

References

  1. Abaqus (2002), Abaqus User Manual-version 6.4. Hibbit, Karlsson and Sorensen Inc., Pawtucket, RI, USA.
  2. API 650 (1991), Welded Steel Tanks for Oil Storage, American Petroleum Institute Standard, Chapter 3, Washington, D.C..
  3. ASCE 7 Standard (2002), Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers, Reston, VA, USA.
  4. Esslinger, M., Ahmed, S. and Schroeder, H. (1971), "Stationary wind loads of open topped and roof-topped cylindrical silos", Der Stalbau, pp. 1-8 (in German).
  5. Flores, F.G. and Godoy, L.A. (1998), "Buckling of short tanks due to hurricanes", Eng. Struct., 20(8), 752-760. https://doi.org/10.1016/S0141-0296(97)00109-0
  6. Godoy, L.A. (1996), "Catastrofes produzidas por foracoes no mar do caribe, capitulo 26 in acidentes estruturais na construcao civil", 2 (Ed. A. J. P. da Cunha, N. A. Lima, V. C. M. de Souza), Editora Pini, Sao Paulo, Brasil, 255-262 (in Portuguese).
  7. Godoy, L.A. and Flores, F.G. (2002), "Imperfection sensitivity to elastic buckling of wind loaded open cylindrical tanks", Struct. Eng. and Mech., 13(5), 533-542. https://doi.org/10.12989/sem.2002.13.5.533
  8. Greiner, R. (1998), Cylindrical shells: Wind loading, Chapter 17 in: Silos (Ed. C. J. Brown and L. Nilssen), EFN Spon, London, pp. 378-399.
  9. Greiner, R. and Derler, P. (1993), Effect of Imperfections on Wind Loaded Cylindrical Shells, Institute for Steel and Shell Structures, Technical University of Graz, A-8010, Graz, Austria.
  10. Gu, Z. and Sun, T. (2001), "Classifications of flow pattern on three circular cylinders in equilateral-triangular arrangements", J. Wind Eng. Ind. Aerodyn., 89, 553-568. https://doi.org/10.1016/S0167-6105(00)00091-X
  11. Jaca, R. and Godoy, L.A. (2003), "Colapso de un tanque metálico en construccion bajo la accion del viento", Revista Internacional de Desastres Naturales, Accidentes e Infraestructura Civil, 3(1), 73-83 (in Spanish).
  12. Kundurpi, P.S., Savamedam, G. and Johns, D.J. (1975), "Stability of cantilever shells under wind loads", J. the Eng. Mech. Div., ASCE, 101(5), 517-530.
  13. Orlando, M. (2001), "Wind-induced interference effects on two adjacent cooling towers", Eng. Struct., 23, 979- 992. https://doi.org/10.1016/S0141-0296(00)00110-3
  14. Portela, G. (2004), Wind Pressures and Buckling of Metal Cantilever Tanks, Ph.D. Dissertation, University of Puerto Rico at Mayagüez, Puerto Rico.
  15. Portela, G. and Godoy, L.A. (2005), "Wind pressures and buckling of cylindrical steel tanks with a conical roof", J. Constr. Steel Res., 61, 786-807. https://doi.org/10.1016/j.jcsr.2004.11.002
  16. Resinger, F. and Greiner, R. (1982), Buckling of Wind-loaded Cylindrical Shells - Application to Unstiffened and Ring-stiffened Steel Tanks, in Buckling of Shells, Ed. Ramn E., Springer, Berlin, 217-281.
  17. Schmidt, H., Binder, B. and Lange, H. (1998), "Postbuckling strength design of open thin-walled cylindrical tanks under wind load", Thin-Walled Structures, 31, 203-220. https://doi.org/10.1016/S0263-8231(98)00009-3
  18. Tsutsui, T., Igarashi, T. and Kamemoto, K. (1997), "Interactive flow around two circular cylinders of different diameters at close proximity. Experiment and numerical analysis by vortex method", J. Wind Eng. Ind. Aerodyn., 67, 279-291.
  19. Virella, J.C. (2004), Buckling of Tanks Subject to Earthquake Loadings, Ph.D. Dissertation, University of Puerto Rico at Mayagüez, Puerto Rico.
  20. Zdravkovich, M.M. (1977), "Review of flow interference between two circular cylinders in various arrangements", ASME J. Fluids Eng., 99(4), 618-632. https://doi.org/10.1115/1.3448871

Cited by

  1. Wind pressure and buckling of grouped steel tanks vol.10, pp.1, 2007, https://doi.org/10.12989/was.2007.10.1.023
  2. Buckling of vertical oil storage steel tanks: Review of static buckling studies vol.103, 2016, https://doi.org/10.1016/j.tws.2016.01.026
  3. Performance of Storage Tanks in Oil Facilities Damaged by Hurricanes Katrina and Rita vol.21, pp.6, 2007, https://doi.org/10.1061/(ASCE)0887-3828(2007)21:6(441)
  4. A reduced stiffness approach for the buckling of open cylindrical tanks under wind loads vol.45, pp.9, 2007, https://doi.org/10.1016/j.tws.2007.07.001
  5. Wind buckling of tanks with conical roof considering shielding by another tank vol.84, 2014, https://doi.org/10.1016/j.tws.2014.06.007
  6. Interference effect and the working mechanism of wind loads in super-large cooling towers under typical four-tower arrangements vol.170, 2017, https://doi.org/10.1016/j.jweia.2017.08.006
  7. Effects of wind girders on the buckling of open-topped storage tanks under quasi-static wind loading vol.124, 2018, https://doi.org/10.1016/j.tws.2017.11.044
  8. Wind loads on large cylindrical open-topped tanks in group vol.78, 2014, https://doi.org/10.1016/j.tws.2014.01.002
  9. Numerical evaluation on shell buckling of empty thin-walled steel tanks under wind load according to current American and European design codes vol.95, 2015, https://doi.org/10.1016/j.tws.2015.07.007
  10. Stability of Open-Topped Storage Tanks With Top Stiffener and One Intermediate Stiffener Subject to Wind Loading vol.140, pp.1, 2017, https://doi.org/10.1115/1.4038723
  11. Extreme and spectrum characteristics of wind loads on super-large cooling tower under different four-tower combinations pp.2048-4011, 2018, https://doi.org/10.1177/1369433218810888
  12. Multi-dimensional extreme aerodynamic load calculation in super-large cooling towers under typical four-tower arrangements vol.25, pp.2, 2017, https://doi.org/10.12989/was.2017.25.2.101
  13. Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 1: Wind tunnel test vol.31, pp.6, 2005, https://doi.org/10.12989/was.2020.31.6.483
  14. Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 2: CFD simulation and finite element analysis vol.31, pp.6, 2005, https://doi.org/10.12989/was.2020.31.6.495