DOI QR코드

DOI QR Code

Floor Impact Sound Isolation Performance by Composition of Ceiling and Wall

천장 및 벽구성 방법이 바닥충격음 차단성능에 미치는 영향에 관한 연구

  • Published : 2005.04.01

Abstract

The impact sounds, generated by the walking of people, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The characteristics and level of this impact noise depends on the object striking the floor, on the basic structure of the floor, and on the finish materials of floor. The focus of this paper is to investigate the amount of improvement impact sound pressure level according to the change of the composition method of ceiling and wall. For this purpose, we tested impact sound pressure level of several cases which is the inserting of mineral wool, the increase of the thickness of air layer, the using of anti-vibration rubber in ceiling and attach the mineral wool on wall in the Floor Impact Sound Test Building of KICT. The results show that the composition method of ceiling and wall is more effective in the reduction of light weight impact sound specially in 125Hz and 250Hz.

Keywords

References

  1. 김명준, 1999, '공동주택 바닥충격음의 부위별 전달특성 평가', 한양대학교 박사학위 논문
  2. 김경우 외3인, 2004, '바닥충격음 실험동 개요 및 성능평가', 대한건축학회 학술발표논문집
  3. 소방시설설치유지및안전관리에관한법률시행령 [별표4](제정 2004.5.29 대통령령 18404호)
  4. 양관섭, 1998, '건축물의 바닥충격음 저감설계기법', 한국건설기술연구원 책임연구과제보고서
  5. 김경우 외3인, 2003, '바닥충격음레벨 영향요인 분석', 한국소음진동공학회 춘계학술대회논문집, pp. 250-260
  6. 김경우 외3인, 2004, '바닥충격음 저감방안에 따른 성능평가', 한국소음진동공학회논문집, 제14권, 제9호, pp. 811-818
  7. 한국표준협회, 2001, KS F 2810-1 바닥충격음 차단성능 현장측정방법 제1부 : 표준 경량충격원에 의한 방법
  8. 한국표준협회, 2001, KS F 2810-2 바닥충격음 차단성능 현장측정방법 제2부 : 표준 중량충격원에 의한 방법