직관 배관의 국부 감육결함에 대한 건전성 평가 모델

Integrity Evaluation Model for a Straight Pipe with Local Wall Thinning Defect

  • 발행 : 2005.05.01

초록

The present study proposes the integrity evaluation model for a straight pipe with local wall thinning defect, which reflects the characteristics of training shape and loading condition in the Piping of nuclear power plant. For this purpose, a series of finite element analyses are performed under various defect geometries and loading conditions, and real pipe experiment data performed previously is employed. The model includes the effect of thinning length as well as thinning depth and width, and also it considers the combined loading effect between internal pressure and bending moment. The proposed model has been validated using the results of finite element analysis and pipe experiment data. The results indicate that the proposed model provides more reliable predictions of pipe failure than the current existing model, in terms of accuracy, consistency, and conservativeness of results.

키워드

참고문헌

  1. Chexal, B., Horowitz, J., Dooley, B., Millett, P., Wood, C. and Jones, R, 1998, 'Flow-Accelerated Corrosion in Power Plant,' EPRVIR-106611-R2
  2. Frank, M., Hans, R. and Helmut, S., 2001, 'Experience with Piping in German NPPs with Respect to Ageing-Related Aspects.,' Nucl. Eng. & Des., Vol. 207, pp.307-316 https://doi.org/10.1016/S0029-5493(01)00339-9
  3. Kim, J.W. and Park, C.Y., 2002, 'An Evaluation of Failure Behavior of Pipe with Local Wall Tinning by Pipe Experiment,' Trans. of KSME (A), Vol. 26, No.4, pp.731-738 https://doi.org/10.3795/KSME-A.2002.26.4.731
  4. Miyazaki, K., Kanno, S., Ishiwata, M., Hasegawa, K., Ahn, S. H. and Ando, K., 1999, 'Fracture behavior of Carbon Steel Pipe with Local Wall Thinning Subjected to Bending Load,' Nucl. Eng. & Des., Vol. 191, pp.195-204 https://doi.org/10.1016/S0029-5493(99)00141-7
  5. JAERI, 1993, Technical Reprt on the Piping Reliability Tests at the Japan Atomic Energy Research Institute (Japanese),' JAERI-M, 93-074, pp.104-115
  6. Wilkowski, G., Stephens, D., Krishnaswamy, P., Leis, B. and Rudland, D., 2000, 'Progress in Development of Acceptance Criteria for Local Thinned Areas in Pipe and Piping Components,' Nucl. Eng. & Des., Vol. 195, pp. 149-169 https://doi.org/10.1016/S0029-5493(99)00245-9
  7. Lim, R., Shim, D.J., Kim, Y.J. and Kim, Y.J., 2003, 'Development of Assessment Methodology for Locally Corroded Pipe Using Reference Stress Concept,' Trans. of KSME (A), Vol. 27, No.7, pp. 1200-1209 https://doi.org/10.3795/KSME-A.2003.27.7.1200
  8. Iyer, S. and Kumar, R., 2002, 'Application of Code Case N-597 for Local Thinning Assessment for Class 1 Piping,' ASME PVP-Vol. 440, pp. 93-101
  9. American Society of Mechanical Engineer, ASME B&PV Sec.XI, App.X (Draft), 2003 (Rev.8)., 'Analysis Evaluation of Internal or External Wall Thinning in Piping Systems.'
  10. Hibbitt, Karlson and Sorensen Inc., 2001, 'ABAQUS ver. 6.2 User's Manual'
  11. Kenninen, M.F., Zahoor, A., Wilkowski, G., Abousayed, I., Msrschall, C., Broek, D., Sampath, S., Rhee, R. and Ahmad, J., 1982, 'Instability Predictions for Circumferentially Cracked Type-304 Stainless Steel Pipes under Dynamic Loading,' EPRI NP-2347, Vol. 1&2
  12. Kiefner, J.F and Vieth, P.R., 1990, 'New Method Corrects Criterion for Evaluating Corroded Pipe,' Oil and Gas Journal, pp.56-59