DOI QR코드

DOI QR Code

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent

계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가

  • 조한구 (한국전기연구원 신소재응용연구그룹) ;
  • 이운용 (한국전기연구원 신소재응용연구그룹) ;
  • 한동희 (한국전기연구원 신소재응용연구그룹) ;
  • 강성화 (충청대학교 산업안전과) ;
  • 최인혁 (전력연구원 전력계통연구실) ;
  • 임기조 (충북대학교 전기전자공학부)
  • Published : 2005.01.01

Abstract

Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

Keywords

References

  1. I. Gutman, R. Hartings, R. Matsuoka, and K. Kondo, 'Experience with IEC 1109 1000h salt fog ageing test for composite insulators', IEEE EI Magazine, Vol. 13, No. 3, p. 12, 1997
  2. A. H. El-Hag, S. Jayaram, and E. A. Cherney, 'Effect of Shed Design on Aging Performance of Silicone Rubber Insulators', 2002 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, p. 363, 2002
  3. N. Yoshimura and M. Nishida, 'Influence of the electrolyte on tracking breakdown of organic insulating materials', IEEE Trans. Electr. Insul., Vol. EI-16, No. 6, p. 510, 1981 https://doi.org/10.1109/TEI.1981.298382
  4. E. M Sherif and A. E. Vlastos, 'Influence of Aging on the Electrical Properties of Composite Insulators', 5th ISH, 51.01, p. 1, 1987
  5. CEA LWTWG-01, 'Dead-end/suspension Composite Insulator for Overhead Distribution Lines', 1996
  6. IEC 60587, 'Test Methods for Evaluating Resistance to Tracking and Erosion of Eelectrical Insulating Materials Used under Severe Ambient Conditions', 1992
  7. 조한구, 이운용, 임기조, 최인혁, 'IEC 61109와 CEA LWTWG 01 시험에 의한 폴리머 애자의 성능비교', 대한전기학회 전기재료연구회 춘계학술대회논문집, p. 70, 2004
  8. 조한구, 한동희, 이운용, 임기조, 최인혁, '계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가', 전기전자재료학회 하계학술대회논문집, p. 11231, 2004
  9. 조한구, 이운용, 강성화, 임기조, 여학규, 지원영, '갓 형상에 따른 폴리머 현수애자의 열화 특성', 전기전자재료학회 추계학술대회논문집, p. 539, 2003