Abstract

A steel-concrete composite column is a recently developed composite system in which the two opposite flanges of the H-shape section are connected by welded links, and the vacant space enclosed by the flanges, web, and links is filled with concrete. Previous experiments on the SC composite column were performed to evaluate its compression and bending and shear strengths, respectively, and they showed fairly good results. In addition to thesestudies, it may be necessary to evaluate the flexural-axial capacity of an SC composite column, because itscolumn members are generally subjected to axial force and bending moment at the same time. In this study, the bending strength of an SC composite column subjected to axial compression force was investigated experimentally. The results of the study showed that the AISC-LRFD provisions representedexcessively low values compared with those of the ACI, Eurocode-4, and Japan Code provisions. The Eurocode-4 provisions represented reasonable evaluations of the strength of the SC composite column composed of a non-compact section.

철골-콘크리트 합성 기둥(이하 SC 합성 기둥)은 철골 플랜지 사이를 연결재로 용접하고, 이런 플랜지 사이에 콘크리트를 채워 시공성과 경제성을 얻을 수 있는 새로운 합성 부재이다. 이 연구의 전단계로서 비조밀단면을 사용한 SC 합성 기둥의 축력 실험을 통해 구조 내력이 우수하다는 것을 입증하였으나, 기둥의 특성상 축력과 휨을 동시에 받고 있기 때문에 후속 실험 연구가 필요하게 되었다. 따라서 일정 축력을 받는 비조밀단면을 가진 SC 합성 기둥의 휨 성능을 강축 및 약축 방향으로 실험을 실시하여 각국 기준식과 비교하여 분석하였다. 실험 결과 모든 방향에 대해서 각국 기준식에서 제시하고 있는 축력-휨 모멘트 내력식을 만족하는 결과를 보이고 있었다. 특히 AISC-LRFD 기준식은 합성 기둥의 내력을 지나치게 안전측으로 고려하고 있다. 또한 추후 SC 합성 기둥의 축력-휨 모멘트 내력식은 EC4 기준식으로 산정하는 것이 철골과 콘크리트의 적합 조건을 고려하지 않은 일본 기준식과 약축 방향 내력을 산정하기 어려운 ACI 기준식보다는 바람직하다.

Keywords

Acknowledgement

Grant : SC 합성 구조 시스템 개발에 관한 연구

Supported by : 삼성물산 건설부문

References

  1. 김성재, 박순전, 김상대 (2002) Steel-Concrete Column의 구조 성능에 관한 실험연구, 한국강구조학회논문집, 한국강구 조학회, 제14권, 제6호, pp. 389-396
  2. 김대곤, 김성훈, 김명관, 이규남, 김석희 (2001) 내화성능이 향 상된 H형강-국부 콘크리트 합성기둥의 실험적 연구, 2001년도 학술발표회 논문집, 한국강구조학회, pp. 457-464
  3. 김범래, 오명호, 김명한, 김대중, 김상대 (2004) 비조밀단면을 가진 SC 합성 기둥의 휨-압축 내력에 관한 실험 연구, 2004년도 추계학술발표회 논문집, 대한건축학회, pp. 19-22
  4. 김요숙, 임성우, 장인화 (2003) 세립형 고강도 구조용 강재를 이용한 보-기둥재의 실험적 평가, 2003년도 추계학술발표 회 논문집, 대한건축학회, 제23권, 제2호, pp. 167-170
  5. 오명호, 김평석, 김명한, 김대중, 김상대 (2004) 비조밀단면을 가진 SC 합성 기둥의 압축 내력에 관한 실험 연구, 대한 건축학회 논문집 구조계, 대한건축학회, 제20권, 제10호, pp. 103-110
  6. 이환수, 오명호, 김상대 (2003) 축력을 받는 SC 합성 기둥의 휨성능에 관한 실험연구, 한국강구조학회논문집, 한국강 구조학회, 제15권, 제1호, pp. 87-96
  7. American Concrete Institute (ACI) (2002) Building code requirements for structural concrete (ACI 318-02) and commentary (318R-02), ACI 318-02, Farmington Hills, Mich
  8. American Institute of Steel Construction (AISC-LRFD) (1999) Load and Resistance Factor Design specification for structural steel buildings, AISC, Chicago
  9. European Committee for Standardization (CEN) (1994), Design of composite steel and concrete structres-part 1-1 : general rules and rules for buildings, Eurocode 4, Brussels, Belgium
  10. Macgregor J. G. (1997) Reinforced Concrete : Mechanics and Design, 3rd Edition, Prentice-Hall, Inc., USA
  11. Mirza S. A., Lacroix E. A. (2004) Comparative Strength Analyses of Concrete-Encased Steel Composite Columns, Journal of Structural Engineering, ASCE, Vol. 130, No. 12, pp. 1941-1953 https://doi.org/10.1061/(ASCE)0733-9445(2004)130:12(1941)
  12. Robert Tremblay, Thierry Chicoine, Bruno Massicotte, James M. Ricles, Le-Wu Lu, (2000) Design Equation for the Axial Capacity of Partially Encased Non- Compact Columns, Proc. Composite Construction IV, Engineering foundation, Banff, Canada
  13. Thierry Chicoine, Bruno Massicotte, Robert Tremblay (2003) Long-Term Behavior and Strength of Partially Encased Composite Columns made with Built-Up Steel Shapes, Journal of Structural Engineering, ASCE, Vol. 129, No. 2, pp. 141-150 https://doi.org/10.1061/(ASCE)0733-9445(2003)129:2(141)
  14. Thierry Chicoine, Robert Tremblay, Bruno Massicotte, James M. Ricles, Le-Wu Lu (2002) Behavior and Strength of Partially Encased Composite Columns with Built-up Shapes, Journal of Structural Engineering, ASCE, Vol. 128, No. 3, pp. 279-288 https://doi.org/10.1061/(ASCE)0733-9445(2002)128:3(279)
  15. Vincent R. (2000) Design and Application of Partially Encased Non-Compact Composite Columns for Highrise Buildings, Proc. Composite Construction IV, Engineering Foundation, Banff, Canada