Abstract
In this study, a lab-scale test was performed to apply the ozone process in drinking water treatment plant using dissolved ai, flotation(DAF). The kinetic study on the ozone decay and hydroxyl(OH) radical formation was investigated by several parameters, such as I.D(Instantaneous ozone demand), $k_c$(ozone decomposition rate), ozone-Ct and OH radical-Ct. Ozonation of several target waters, such as raw water, DAF treated water and filtrate, was conducted to select the optimum position and dosage of ozone process. The highest value of Ozone-Ct and OH radical-Ct was observed at DAF treated water at initial run time($0{\sim}30\;min$). From the results of ozonation, the intermediate ozonation was proposed as the optimum position and the effective dose of ozone was determined to be $1{\sim}2\;mg/L$.
본 연구에서는 용존공기부상법(DAF)을 이용한 정수처리 공정에 오존을 도입하기 위하여 실험실 규모의 실험이 수행되었다. 오존의 수처리 적용시 공정제어 인자로 활용할 수 있는 I.D, $k_c$, 오존-Ct 및 OH 라디칼-Ct 등에 대한 반응속도론적 연구를 실시하였다. 또한 원수, DAF 처리수 및 여과수에 대한 오존처리 실험을 실시하여 오존공정의 최적 위치 및 주입량을 도출하였다. 실험 결과 오존-Ct와 OH 라디칼-Ct는 DAF 처리수에서 가장 높게 측정되었으며, DAF 공정의 체류시간인 30분 이후에도 계속적으로 유지되었다. 또한 각 공정수에 대한 오존처리 실험을 실시한 결과, 중오존이 전 후오존에 비해 높은 효율을 기대할 수 있을 것으로 나타났으며, 최적 오존주입농도는 $1{\sim}2\;mg/L$로 판단되었다. 이러한 결과로부터 중오존 / DAF(ozoflotation) 공정 도입을 위한 기초자료로서 활용하고자 하였다.