도심지 변전소 지락사고시 인근 저항성간섭 영향 해석

Analysis of Conductive Interference Around Substation Exclusively Fed by Cables Under Ground Fault Condition

  • 최종기 (한국전력공사 전력연구원) ;
  • 이동일 (한국전력공사 전력연구단 송전기술그룹) ;
  • 김재준 (한국전력공사 송변전건설처 건설기술팀) ;
  • 유연표 (한국전력공사 전자통신처 전력유도팀) ;
  • 정창수 (한국전력공사 전자통신처 전력유도팀) ;
  • 김경철 (홍익대학교 전기공학과)
  • 발행 : 2005.12.01

초록

Recently, substations have been constructed in GIS (Gas Insulated Switchgear) and indoor type because of the increasing difficulties of securing locations. In case of urban substations, it is also common that the substations are exclusively fed by underground cables. Sometimes, the infrastructures in urban area, such as communication facilities, are located near substations to be constructed. In this paper, we examined such a case that a branch office building of KT(Korea Telecom) was located near 154 kV underground GIS substation under construction with about 100 meters of the lateral distance between two facilities. GPR (Ground Potential Rise) at the substation and the transferred earth potential at the KT building through the earth in SLG (Single-Line-to- Ground) fault condition were investigated based on a series of computer simulations. The calculated earth potential at a distance of 100 m from the substation was below 120 V which satisfying the limit value of 650 V.

키워드

참고문헌

  1. S.T.Sobral, J.B.Barbosa, V.S.Costa, 'Ground potential rise characteristics of, urban step-down substations fed by power cables-a practical example', IEEE Trans. on PD, vol.3, no.4, Oct. 1988 https://doi.org/10.1109/61.193956
  2. J.T.Villas, D.Mukhedkar, V.R.Fernandes, 'Ground grid design of a transition station system-a typical example of fault transfer', IEEE Trans. on PD, voI.5,pp.124-129, Jan. 1990 https://doi.org/10.1109/61.107264
  3. J.M.Nahman, V.B.Djordjevic, D.D.Salamon, effects of HV and MV under- ground cables associated with urban distribution substations', IEEE Trans. on PD, vol.17, , pp.111-116, Jan. 2002 https://doi.org/10.1109/61.974196
  4. S.Sebo, 'Zero sequence current distribution along transmission lines', IEEE Trans. on PAS, vol. PAS-88, No.6, Jun. 1969, pp.910-919 https://doi.org/10.1109/TPAS.1969.292428
  5. J.M.Nahman, 'Proximity effects on the ground fault current distribution within the earthing system formed by a substation and the associated transmission lines', lEE Proc. -Generation, Transmission and Distribution, Vol.135, No.6, 1988, pp.497-502 https://doi.org/10.1049/ip-c.1988.0065
  6. L.M.Popovic, 'Practical method for evaluating ground fault current distribution in station supplied by an unhomogeneous line', IEEE Trans. on PD, Vol.12, Apr. 1997, pp.722-727 https://doi.org/10.1109/61.584356
  7. EPRI EL-2699, Transmission Line Grounding, Vol.1, 1982
  8. ITU - T Directives concerning the protection of telecommunication lines against harmful effects from electric power and electrified railway lines, Volume VI - Danger and disturbance, 1989
  9. 정통부 고시 제2001-99호, 전력유도의 구체적 산출방법에 관한 기술기준, 2001
  10. IEEE guide for measurement of impedance and safety characteristics of large, extended or interconnected grounding systems, IEEE Std 81.9-1991, pp. 38
  11. IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault, IEEE Std. 367-1997
  12. ITU-T Recommendation K.8, Separation in the soil between telecommunication cables and earthing system of power facilities, 1988
  13. F. P. Dawalibi, F. Donoso, 'Integrated Analysis Software for Grounding, EMF, and EMI', IEEE Computer Applications in Power, Vol.6, No.2, April 1993, pp. 19-24 https://doi.org/10.1109/67.207467
  14. SPLITS Users' Manual, Safe Engineering Services & technologies ltd., 2000
  15. TRALIN Users' Manual, Safe Engineering Services & technologies ltd., 2000
  16. 한전 전력연구원, '전력설비 지락사고시 도체-대지간 고장전류 분포', 한국부식학회 전기방식위원회 특별심포지움, 2001