참고문헌
- Chandran, K. B., Khalighi, B. and Chen, C. J., 1985, 'Experimental Study of Physiological Pulsatile Flow Past Valve Prostheses in a Model of Human Aorta-II. Tiling Disc Valves and the Effect of Orientation,' Journal of Biomechanics, Vol. 18, No. 10, pp.773-780 https://doi.org/10.1016/0021-9290(85)90052-1
- Choi, C. R. and Kim, C. N., 2001, 'Characteristics of Transient Blood Flow in MHVs with Different Maximum Opening Angles Using Fluid-Structure Interaction Method,' Korean J. Chem. Eng., Vol. 18, No.6, pp. 809-815 https://doi.org/10.1007/BF02705601
- Choi, C. R., 2003, 'An Experimental and Numerical Analysis on Transient Three-dimensional Flow Fields through Bileaflet Mechanical Heart Valve (MHV) using Particle Image Velocity (PIV) and Fluid-Structure Interaction (FSI) Model,' Ph.D. dissertation, Kyunghee University, Korea
- Choi, C. R., Kim, C. N., Kwon, Y. J. and Lee, J. W., 2003, 'Pulsatile Blood Flows Through a Bileaflet Mechanical Heart Valve with Different Approach Methods of Numerical Analysis ; Pulsatile Flows with Fixed Leaflets and Interacted with Moving Leaflets,' KSME International Journal, Vol. 17, No.7, pp. 1073-1082
- De Hart, J., Peters, G. W. M., Schreurs, P. J. G. and Baaijens, F. P. T., 2000, 'A Two-Dimensional Fluid-Structure Interaction Model of the Aortic Value,' Journal of Biomechanics, Vol. 33, pp. 1079-1088 https://doi.org/10.1016/S0021-9290(00)00068-3
- Edmunds Jr., L. H., 1982, 'Thromboembolic Complication of Current Cardiac Valvular Prostheses,' Annals in Thoracic Surgery, Vol. 34, pp.96-106 https://doi.org/10.1016/S0003-4975(10)60862-4
- Farahifar, D., Cassot, F. and Bodard, H., 1985, 'Velocity Profiles in the Two Prosthetic Heart Valves Using a New Cardiovascular Simulator,' Journal of Biomechanics, Vol. 18, No. 10, pp.789-802 https://doi.org/10.1016/0021-9290(85)90054-5
- Giersiepen, M., Wurzinger, L. J., Opitz, R. and Reul, H., 1984, 'Estimation of Shear Stress Related Blood Damage in Heart Valve Prostheses in Vitro Comparison of 25 mm Aortic Valves,' Int. J. of Artificial Organs, Vol. 13, No.5, pp.300-306
- Krafczyk, M., Cerrolaza, M., Schulz, M. and Rank, E., 1998, 'Analysis of 3D Transient Blood Flow Passing Through an Artificial Aortic Valve by Lattice-Boltzmann Methods,' Journal of Biomechanics, Vol. 31, pp. 453-462 https://doi.org/10.1016/S0021-9290(98)00036-0
- Mauro, G., Carla, D., Giuseppe, D. and Vincenzo, B., 2001, 'The Influence of the Leaflets' Curvature in the Flow Fields in Two Bileaflet Prosthetic Heart Valves,' Journal of Biomechanics, Vol. 34, pp. 613-621 https://doi.org/10.1016/S0021-9290(00)00240-2
- Paul, R., Schugner, F., Reul, H. and Rau, G., 1999, 'Recent Findings in Flow Induced Blood Damage : Critical Shear Stresses and Exposure Times Obtained with a High Shear Couette-System,' Artificial Organs, Vol. 23, No.7, pp. 680-688
- Rosseau, E. P. M., Van de Ven, A. P. C., Van Steenhoven, A. A. and Seroo, J. M., 1984, 'Design of a System for the Accelerated Loading of Heart Valve Prostheses,' Journal of Biomechanics, Vol. 17, No.2, pp. 145-153 https://doi.org/10.1016/0021-9290(84)90132-5
- Sallam, I. A., Shaw, A. and Bain, W. H., 1976, 'Experimental Evaluation of Mechanical Haemolysis with Starr-Edwards, Kay-Shiley and Bjork-Shiley valves,' Scandinavian Journal of Thoracic and Cardiovascular Surgery, Vol. 10, pp.117-122 https://doi.org/10.3109/14017437609167777
- Skalak, R., 1982, 'Finite Elements in Biofluid,' FE Analysis in Biomechanics
- Stein, P. D. and Sabbah, H. N., 1974, 'Measured Turbulence and Its Effect in Thrombus Formation,' Circulation Research., Vol. 35, pp. 608-614 https://doi.org/10.1161/01.RES.35.4.608
- Thubrika, M. J., Selim, G., Robicsek, F. and Fowler, B., 1996a, 'Effect of the Sinus Geometry on the Dynamics of Bioprosthetic Heart Valves (abstract),' Ann. Biomed. Eng., Vol. 24, S3
-
Thubrika, M. J., Selim, G., Robicsek, F. and Fowler, B., 1996b, 'Effect of the Sinus Geometry on the Dynamics of Bioprosthetic Heart Valves (abstract),' Proceedings of the
$18^{th}$ Annual International Conference of the IEEE Engineering in Medicine and Biology Society Amsterdam, The Netherlands, pg. 10, November https://doi.org/10.1109/IEMBS.1996.652841 - Tillman, W., Reul, H., Herold, M., Bruss, K. H. and Van Gilse, J., 1984, 'In Vitro Wall Shear Measurements at Aortic Valve Prostheses,' Journal of Biomechanics, Vol. 17, No.4, pp.263-279 https://doi.org/10.1016/0021-9290(84)90137-4
- Woo, Y. R. and Yoganathan, A. P., 1986, 'Pulsatile Flow Velocity and Shear Stress Measurements in the St. Jude Valve Prosthesis,' Scandinavian Journal of Thoracic and Cardiovascular Surgery, Vol. 20, pp. 15-28 https://doi.org/10.3109/14017438609105910
-
Yang, H. Q. and Makhijani, V. B., 1994, 'A Strong Coupled Pressure-based CFD Algorithm for Fluid-Structure Interaction,' Proceeding of
$32^{nd}$ Aerospace Sciences Meeting and Exhibition, Reno, NV, AIAA-94-0719 - Yoganathan, A. P., Corcoran, W. H. and Harrison, E. C., 1979, 'In Vitro Velocity Measurements in the Vicinity of Aortic Prostheses,' Journal of Biomechanics, Vol. 12, pp. 135-152 https://doi.org/10.1016/0021-9290(79)90153-2