두 개의 비대칭 축방향 관통균열이 존재하는 증기발생기 세관의 소성붕괴압력 평가

Evaluation of Plastic Collapse Pressure for Steam Generator Tube with Non-Aligned Two Axial Through-Wall Cracks

  • 발행 : 2005.08.01

초록

The $40\%$ of wall thickness criterion which has been used as a plugging rule is applicable only to a single cracked steam generator tubes. In the previous studies performed by authors, several failure prediction models were introduced to estimate the plastic collapse pressures of steam generator tubes containing collinear or parallel two adjacent axial through-wall cracks. The objective of this study is to examine the failure prediction models and propose optimum ones for non-aligned two axial through-wall cracks in steam generator tubes. In order to determine the optimum ones, a series of plastic collapse tests and finite element analyses were carried out for steam generator tubes with two machined non-aligned axial through-wall cracks. Thereby, either the plastic zone contact model or COD based model was selected as the optimum one according to axial distance between two clacks. Finally, the optimum failure prediction model was used to demonstrate the conservatism of flaw characterization rules for various multiple flaws according to ASME code.

키워드

참고문헌

  1. USNRC, 1976, 'Bases for Plugging Degraded PWR Steam Generator Tubes,' Regulatory Guide 1.121
  2. ASME, 1998, 'Rules for Inservice Inspection of Nuclear Power Plant Components,' ASME Boiler and Pressure Vessel Code, Section XI
  3. Yu, Y.J., Kim, J.H., Kim, Y. and Kim, Y.J., 1994, 'Development of Steam Generator Tube Plugging Criteria for Axial Crack,' ASME PVP, Vol. 280, pp. 79-83
  4. Gorman, J.A., Harris, J.E. and Lowenstein, D.B., 1995, 'Steam Generator Tube Fitness-for-Service Guidelines,' AECB Report, No. 2.228.2
  5. Lee, J.H., Park, Y.W., Song, M.H., Kim, Y.J. and Moon, S.I., 2000, 'Determination of Equivalent Single Crack Based on Coalescence Criterion of Collinear Axial Cracks,' Nuclear Engineering and Design, Vol. 205, pp. 1-11 https://doi.org/10.1016/S0029-5493(00)00368-X
  6. Murakami, Y., 1987, 'Stress Intensity Factors Handbook,' pp. 204-205
  7. Hasegawa, H., Miyazaki, K. and Kanno, S., 2001, 'Interaction Criteria for Multiple Flaws on the Basis of Stress Intensity Factors,' ASME PVP, Vol. 422, pp. 23-29
  8. Moussa, W.A., Bell, R. and Tan, C.L., 1999, 'The Interaction of Two Parallel Non-Coplanar Identical Surface Cracks under Tension and Bending,' Int. J. PVP, Vol. 76, pp. 135-145 https://doi.org/10.1016/S0308-0161(98)00125-2
  9. Chang, Y.S., Moon, S.I., Kim, Y.J., Lee, J.H., Song, M.H. and Choi. Y.H., 2004, 'Assessment of Steam Generator Tube with Multiple Axial Through-Wall Cracks,' Proceedings of Asian Society for Integrity of Nuclear Components
  10. Kim, Y.J., Choy, Y.S. and Lee, J.H., 1993, 'Development of Fatigue Life Prediction Program for Multiple Surface Cracks,' ASTM STP 1189, pp. 536-550
  11. Shibata, K., Yokoyama, N., Ohba, T., Kawamura, T. and Miyazono, S., 1985, 'Growth Evaluation of Fatigue Cracks from Multiple Surface Flaws (I),' J. Japanese Nuclear Society, Vol. 28, No. 2, pp. 250-262
  12. Shibata, K., Yokoyama, N., Ohba, T., Kawamura, T. and Miyazono, S., 1986, 'Growth Evaluation of Fatigue Cracks from Multiple Surface Flaws (II),' J. Japanese Nuclear Society, Vol. 28, No. 3, pp. 258-265
  13. Moon, S.I., Chang, Y.S., Kim, Y.J., Lee, J.H., Song, M.H., Choi, Y.H. and Hwang, S.S., 2004, 'Evaluation of Plastic Collapse Behavior for Multiple Cracked Structures,' J. Korean Society of Mechanical Engineers, Vol. 28, No. 11, pp. 1813-1821 https://doi.org/10.3795/KSME-A.2004.28.11.1813
  14. Mcllree, A., 2002, 'Steam Generator Tubing Burst Testing and Leak Rate Testing Guidelines,' EPRI, Technical Report 1006783
  15. Erdogan, F., 1976, 'Ductile Failure Theories for Pressurized Pipes and Containers,' Int. J. PVP, Vol. 4, pp. 253-283